Nandish Siddeshappa
Nandish Siddeshappa has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Niranjana Sampathila
Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India
3 shared publications - Anusha Krishnamoorthy
Department of Biomedical Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, Karnataka, India
1 shared publication - Giliyar Muralidhar Bairy
Department of Biomedical Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education (MAHE), Manipal, India
1 shared publication - Girish Thunga
Department of Pharmacy Practice, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal, India
1 shared publication - Hilda Mayrose
Department of Biomedical Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education (MAHE), Manipal, India
1 shared publication - Kaushik Nayak
Department of Medical Imaging Technology, Manipal College of Health Professions Karnataka Manipal 576104 Manipal Academy of Higher Education
1 shared publication
Latest Publications
- Open Access
- 6 February 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (3) , 500
Diagnostic Accuracy of Artificial Intelligence Models for Differentiation of Squamous Cell Carcinoma and Adenocarcinoma of Lung—A Systematic Review
Background/Objectives: Lung cancer remains the leading cause of cancer-related deaths worldwide, with Non-Small Cell Lung Cancer (NSCLC) accounting for the majority of cases, primarily Squamous Cell Carcinoma (SCC) and Adenocarcinoma (ADC). The aim of this systematic review is to summarise and critically appraise the performance of machine learning (ML)-based radiomics models in the differential diagnosis and overall survival analysis for lung SCC and ADC. Methods: PRISMA standards were followed in conducting the review. The quality of the studies was assessed using the Radiomics quality score (RQS) tool. Results: A total of 11 studies were included, demonstrating that deep learning and radiomics-based machine learning models significantly improve the non-invasive classification of lung squamous cell carcinoma and adenocarcinoma. Deep learning systems achieved an accuracy of 67–97%, and machine learning models showed an accuracy of 75–87%. The integration of radiomic features further enhanced diagnostic precision, showing strong potential for reliable histologic subtype differentiation. Conclusions: Machine learning-based radiomics models and deep learning significantly enhance the non-invasive, accurate differentiation of lung squamous and adenocarcinoma cell carcinoma when combined with clinical and pathological data.
- 6 February 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (3) , 500
Open AccessDiagnostic Accuracy of Artificial Intelligence Models for Differentiation of Squamous Cell Carcinoma and Adenocarcinoma of Lung—A Systematic Review
Background/Objectives: Lung cancer remains the leading cause of cancer-related deaths worldwide, with Non-Small Cell Lung Cancer (NSCLC) accounting for the majority of cases, primarily Squamous Cell Carcinoma (SCC) and Adenocarcinoma (ADC). The aim of this systematic review is to summarise and critically appraise the performance of machine learning (ML)-based radiomics models in the differential diagnosis and overall survival analysis for lung SCC and ADC. Methods: PRISMA standards were followed in conducting the review. The quality of the studies was assessed using the Radiomics quality score (RQS) tool. Results: A total of 11 studies were included, demonstrating that deep learning and radiomics-based machine learning models significantly improve the non-invasive classification of lung squamous cell carcinoma and adenocarcinoma. Deep learning systems achieved an accuracy of 67–97%, and machine learning models showed an accuracy of 75–87%. The integration of radiomic features further enhanced diagnostic precision, showing strong potential for reliable histologic subtype differentiation. Conclusions: Machine learning-based radiomics models and deep learning significantly enhance the non-invasive, accurate differentiation of lung squamous and adenocarcinoma cell carcinoma when combined with clinical and pathological data.
- Open Access
Channel Intensity and Edge-Based Estimation of Heart Rate via Smartphone Recordings
Smartphones, today, come equipped with a wide variety of sensors and high-speed processors that can capture, process, store, and communicate different types of data. Coupled with their ubiquity in recent years, these devices show potential as practical and portable healthcare monitors that are both cost-effective and accessible. To this end, this study focuses on examining the feasibility of smartphones in estimating the heart rate (HR), using video recordings of the users’ fingerprints. The proposed methodology involves two-stage processing that combines channel-intensity-based approaches (Channel-Intensity mode/Counter method) and a novel technique that relies on the spatial and temporal position of the recorded fingerprint edges (Edge-Detection mode). The dataset used here included 32 fingerprint video recordings taken from 6 subjects, using the rear camera of 2 smartphone models. Each video clip was first validated to determine whether it was suitable for Channel-Intensity mode or Edge-Detection mode, followed by further processing and heart rate estimation in the selected mode. The relative accuracy for recordings via the Edge-Detection mode was 93.04%, with a standard error of estimates (SEE) of 6.55 and Pearson’s correlation r > 0.91, while the Channel-Intensity mode showed a relative accuracy of 92.75%, with an SEE of 5.95 and a Pearson’s correlation r > 0.95. Further statistical analysis was also carried out using Pearson’s correlation test and the Bland–Altman method to verify the statistical significance of the results. The results thus show that the proposed methodology, through smartphones, is a potential alternative to existing technologies for monitoring a person’s heart rate.
Open AccessChannel Intensity and Edge-Based Estimation of Heart Rate via Smartphone Recordings
Smartphones, today, come equipped with a wide variety of sensors and high-speed processors that can capture, process, store, and communicate different types of data. Coupled with their ubiquity in recent years, these devices show potential as practical and portable healthcare monitors that are both cost-effective and accessible. To this end, this study focuses on examining the feasibility of smartphones in estimating the heart rate (HR), using video recordings of the users’ fingerprints. The proposed methodology involves two-stage processing that combines channel-intensity-based approaches (Channel-Intensity mode/Counter method) and a novel technique that relies on the spatial and temporal position of the recorded fingerprint edges (Edge-Detection mode). The dataset used here included 32 fingerprint video recordings taken from 6 subjects, using the rear camera of 2 smartphone models. Each video clip was first validated to determine whether it was suitable for Channel-Intensity mode or Edge-Detection mode, followed by further processing and heart rate estimation in the selected mode. The relative accuracy for recordings via the Edge-Detection mode was 93.04%, with a standard error of estimates (SEE) of 6.55 and Pearson’s correlation r > 0.91, while the Channel-Intensity mode showed a relative accuracy of 92.75%, with an SEE of 5.95 and a Pearson’s correlation r > 0.95. Further statistical analysis was also carried out using Pearson’s correlation test and the Bland–Altman method to verify the statistical significance of the results. The results thus show that the proposed methodology, through smartphones, is a potential alternative to existing technologies for monitoring a person’s heart rate.
- 19 July 2022
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 131, 102361
Artificial intelligence in acute respiratory distress syndrome: A systematic review
- 19 July 2022
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 131, 102361
Artificial intelligence in acute respiratory distress syndrome: A systematic review
- Open Access
- 17 December 2021
- Published by F1000 Research Ltd in F1000Research
- Vol. 10, 1292
X-ray versus computerized tomography (CT) images for detection of COVID-19 using deep learning
Background: The recent outbreak of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and the disease corresponding to it (coronavirus disease 2019; COVID-19) has been declared a pandemic by the World Health Organization. COVID-19 has become a global crisis, shattering health care systems, and weakening economies of most countries. The current methods of testing that are employed include reverse transcription polymerase chain reaction (RT-PCR), rapid antigen testing, and lateral flow testing with RT-PCR being used as the golden standard despite its accuracy being at a mere 63%. It is a manual process which is time consuming, taking about an average of 48 hours to obtain the results. Alternative methods employing deep learning techniques and radiologic images are up and coming. Methods : In this paper, we used a dataset consisting of COVID-19 and non-COVID-19 folders for both X-Ray and CT images which contained a total number of 17,599 images. This dataset has been used to compare 3 (non-pre-trained) CNN models and 5 pre-trained models and their performances in detecting COVID-19 under various parameters like validation accuracy, training accuracy, validation loss, training loss, prediction accuracy, sensitivity and the training time required, with CT and X-Ray images separately. Results: Xception provided the highest validation accuracy (88%) when trained with the dataset containing the X- ray images while VGG19 provided the highest validation accuracy (81.2%) when CT images are used for training. Conclusions: The model, VGG16, showed the most consistent performance, with a validation accuracy of 76.6% for CT images and 87.76% for X-ray images. When comparing the results between the modalities, models trained with the X-ray dataset showed better performances than the same models trained with CT images. Hence, it can be concluded that X-ray images provide a higher accuracy in detecting COVID-19 making it an effective method for detecting COVID-19 in real life.
- 17 December 2021
- Published by F1000 Research Ltd in F1000Research
- Vol. 10, 1292
Open AccessX-ray versus computerized tomography (CT) images for detection of COVID-19 using deep learning
Background: The recent outbreak of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and the disease corresponding to it (coronavirus disease 2019; COVID-19) has been declared a pandemic by the World Health Organization. COVID-19 has become a global crisis, shattering health care systems, and weakening economies of most countries. The current methods of testing that are employed include reverse transcription polymerase chain reaction (RT-PCR), rapid antigen testing, and lateral flow testing with RT-PCR being used as the golden standard despite its accuracy being at a mere 63%. It is a manual process which is time consuming, taking about an average of 48 hours to obtain the results. Alternative methods employing deep learning techniques and radiologic images are up and coming. Methods : In this paper, we used a dataset consisting of COVID-19 and non-COVID-19 folders for both X-Ray and CT images which contained a total number of 17,599 images. This dataset has been used to compare 3 (non-pre-trained) CNN models and 5 pre-trained models and their performances in detecting COVID-19 under various parameters like validation accuracy, training accuracy, validation loss, training loss, prediction accuracy, sensitivity and the training time required, with CT and X-Ray images separately. Results: Xception provided the highest validation accuracy (88%) when trained with the dataset containing the X- ray images while VGG19 provided the highest validation accuracy (81.2%) when CT images are used for training. Conclusions: The model, VGG16, showed the most consistent performance, with a validation accuracy of 76.6% for CT images and 87.76% for X-ray images. When comparing the results between the modalities, models trained with the X-ray dataset showed better performances than the same models trained with CT images. Hence, it can be concluded that X-ray images provide a higher accuracy in detecting COVID-19 making it an effective method for detecting COVID-19 in real life.