Magnetic resonance phase velocity mapping through NiTi stents in a flow phantom model
Open Access
- 20 December 2004
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 21 (1) , 59-65
Abstract
Purpose: To assess constant and pulsatile flow velocity within the lumen of a peripheral NiTi stent using phase velocity mapping for comparison with independent assessments of flow velocity in a phantom model.Materials and Methods: A 9 × 20‐mm stent installed in flexible tubing was placed in a phantom filled with stationary fluid. Constant and pulsatile flow (produced by a pump programmed to produce a simulation of the carotid artery flow) was assessed using phase velocity mapping at 4.1 T (for constant flow) and at 1.5 T (for pulsatile flow). In all cases 256 × 256 gradient echo phase velocity maps were acquired. For the pulsatile flow condition, cine images with acquisition gated to the pump cycle were acquired with 40 msec temporal resolution across the simulated cardiac cycle. Computed flow volume rates were compared with fluid volume collection for the constant flow model, and with ultrasonic Doppler flow meter measurements for the pulsatile model.Results: The data showed that volume flow rate assessments by phase velocity mapping agreed with independent measurements within 10% to 15%.Conclusion: Phase velocity mapping of the lumen of peripheral size NiTi stents is possible in an in vitro model. J. Magn. Reson. Imaging 2005;21:59–65.Keywords
This publication has 30 references indexed in Scilit:
- Magnetic resonance angiography minimizes need for arteriography after inadequate carotid duplex ultrasound scanningJournal of Vascular Surgery, 2003
- Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine modelBiomaterials, 2002
- Effect of acquisition parameters on the accuracy of velocity encoded cine magnetic resonance imaging blood flow measurementsJournal of Magnetic Resonance Imaging, 2002
- Morphologic and functional evaluation of coronary artery bypass conduitsJournal of Magnetic Resonance Imaging, 1999
- Error assessment due to coronary stents in flow-encoded phase contrast MR angiography: a phantom studyJournal of Magnetic Resonance Imaging, 1999
- Evaluation of coronary artery bypass grafts by magnetic resonance imagingJournal of Magnetic Resonance Imaging, 1999
- Fast magnetic resonance imaging of the heartEuropean Journal of Radiology, 1999
- Intraluminal signal intensity of iliac artery stents investigated by contrast-enhanced three-dimensional MR angiographyComputerized Medical Imaging and Graphics, 1998
- Combined analysis of spatial and velocity displacement artifacts in phase contrast measurements of complex flowsJournal of Magnetic Resonance Imaging, 1997
- Three-dimensional numerical analysis of pulsatile flow and wall shear stress in the carotid artery bifurcationJournal of Biomechanics, 1991