Internal Energy Deposition in Dielectric Barrier Discharge Ionization is Significantly Lower than in Direct Analysis in Real-Time Mass Spectrometry*
Open Access
- 12 September 2017
- journal article
- research article
- Published by CSIRO Publishing in Australian Journal of Chemistry
- Vol. 70 (11) , 1219-1226
Abstract
The extent of internal energy deposition using three different plasma-based ionization mass spectrometry (MS) methods, atmospheric pressure chemical ionization (APCI), direct analysis in real time (DART), and active capillary dielectric barrier discharge ionization (DBDI), was investigated using benzylammonium ‘thermometer’ ions. Ions formed by DBDI were activated significantly less than those that were formed by DART and APCI under these conditions. Thermal ion activation by DART can be reduced slightly by positioning the DART source further from the capillary entrance to the MS and reducing the heat that is applied to metastable atoms exiting the DART source. For example, the average ion internal energy distribution decreased by less than 10 % (166.9 ± 0.3 to 152.2 ± 1.0 kJ mol-1) when the distance between the DART source and the MS was increased by 250 % (10 to 25 mm). By lowering the DART temperature from 350 to 150°C, the internal energy distributions of the thermometer ions decreased by ~15 % (169.93 ± 0.83 to 150.21 ± 0.52 kJ mol-1). Positioning the DART source nozzle more than 25 mm from the entrance to the MS and decreasing the DART temperature further resulted in a significant decrease in ion signal. Thus, varying the major DART ion source parameters had minimal impact on the ‘softness’ of the DART ion source under these conditions. Overall, these data indicate that DBDI can be a significantly ‘softer’ ion source than two of the most widely used plasma-based ion sources that are commercially available.Keywords
This publication has 47 references indexed in Scilit:
- Ambient Characterization of Synthetic Fibers by Laser Ablation Electrospray Ionization Mass SpectrometryAnalytical Chemistry, 2017
- Medical Swab Analysis Using Desorption Electrospray Ionization Mass Spectrometry: A Noninvasive Approach for Mucosal DiagnosticsAnalytical Chemistry, 2017
- Differential Lipid Profiles of Normal Human Brain Matter and Gliomas by Positive and Negative Mode Desorption Electrospray Ionization – Mass Spectrometry ImagingPLOS ONE, 2016
- Direct Analysis in Real Time (DART) and a portable mass spectrometer for rapid identification of common and designer drugs on-siteForensic Chemistry, 2016
- Infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging analysis of biospecimensThe Analyst, 2016
- Combined use of direct analysis in real-time/Orbitrap mass spectrometry and micro-Raman spectroscopy for the comprehensive characterization of real explosive samplesAnalytical and Bioanalytical Chemistry, 2016
- Solid-phase microextraction low temperature plasma mass spectrometry for the direct and rapid analysis of chemical warfare simulants in complex mixturesThe Analyst, 2016
- Direct analysis in real time – High resolution mass spectrometry as a valuable tool for the pharmaceutical drug developmentTalanta, 2014
- Real-time detection of chemical warfare agent simulants in forensic samples using active capillary plasma ionization with benchtop and field-deployable mass spectrometersAnalytical Methods, 2014
- Desorption electrospray ionization mass spectrometric analysis of organophosphorus chemical warfare agents using ion mobility and tandem mass spectrometryRapid Communications in Mass Spectrometry, 2010