Morphy C. Dumlao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Morphy C. Dumlao has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- William Alexander Donald
School of Chemistry, University of New South Wales
9 shared publications - Leigh Mervyn Schmidtke
School of Agricultural, Environmental and Veterinary Sciences, Charles Sturt University, Locked Bag 588, Wagga Wagga, NSW 2678, Australia; Gulbali Institute, Charles Sturt University, Wagga Wagga, NSW 2678, Australia; The Australian Research Council Training Centre for Innovative Wine Production, University of Adelaide (Waite Campus), 5064, Australia
6 shared publications - Christopher C. Steel
National Wine and Grape Industry Centre, Charles Sturt University, Wagga Wagga, Australia
4 shared publications - Liang Jiang
Gulbali institute Charles Sturt University Wagga Wagga New South Wales Australia
4 shared publications Daming Zhang
School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, NSW, 2052, Australia
2 shared publications- Dan Xiao
School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, NSW, Australia
2 shared publications
Latest Publications
- Open Access
Rydberg Atom-Based Sensors: Principles, Recent Advances, and Applications
Rydberg atoms are neutral atoms excited to high principal quantum number states, which endows them with exaggerated properties such as large electric dipole moments, long lifetimes, and extreme sensitivity to external electromagnetic fields. These characteristics form the foundation of Rydberg atom-based sensors, an emerging class of quantum devices capable of optically detecting electric fields across frequencies from DC to the terahertz regime. Rydberg-based electrometry operates through both Autler–Townes (AT) splitting of resonant Rydberg transitions and Stark-shift measurements for high-frequency or far-detuned fields, enabling broadband field sensing from DC to the THz regime. Using ladder-type electromagnetically induced transparency (EIT) and AT splitting, these sensors enable non-invasive, SI-traceable measurements of field amplitude, frequency, phase, and polarization. Recent developments have demonstrated broadband electric field probes, voltage calibration standards, and compact RF receivers based on thermal vapor cells and integrated photonic architectures. Furthermore, innovations in multi-photon EIT, superheterodyne readout, and multi wave mixing have expanded the dynamic range and bandwidth of Rydberg-based electrometry. Despite challenges related to environmental perturbations, linewidth broadening, and laser stabilization, ongoing advances in atomic control, hybrid photonic integration, and EIT-based readout promise scalable, chip-compatible sensors. This review summarizes the physical principles, experimental progress, and emerging applications of Rydberg atom-based sensing, emphasizing their potential for next generation quantum metrology, wireless communication, and precision field mapping.
Open AccessRydberg Atom-Based Sensors: Principles, Recent Advances, and Applications
Rydberg atoms are neutral atoms excited to high principal quantum number states, which endows them with exaggerated properties such as large electric dipole moments, long lifetimes, and extreme sensitivity to external electromagnetic fields. These characteristics form the foundation of Rydberg atom-based sensors, an emerging class of quantum devices capable of optically detecting electric fields across frequencies from DC to the terahertz regime. Rydberg-based electrometry operates through both Autler–Townes (AT) splitting of resonant Rydberg transitions and Stark-shift measurements for high-frequency or far-detuned fields, enabling broadband field sensing from DC to the THz regime. Using ladder-type electromagnetically induced transparency (EIT) and AT splitting, these sensors enable non-invasive, SI-traceable measurements of field amplitude, frequency, phase, and polarization. Recent developments have demonstrated broadband electric field probes, voltage calibration standards, and compact RF receivers based on thermal vapor cells and integrated photonic architectures. Furthermore, innovations in multi-photon EIT, superheterodyne readout, and multi wave mixing have expanded the dynamic range and bandwidth of Rydberg-based electrometry. Despite challenges related to environmental perturbations, linewidth broadening, and laser stabilization, ongoing advances in atomic control, hybrid photonic integration, and EIT-based readout promise scalable, chip-compatible sensors. This review summarizes the physical principles, experimental progress, and emerging applications of Rydberg atom-based sensing, emphasizing their potential for next generation quantum metrology, wireless communication, and precision field mapping.
- Open Access
- 2 July 2025
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 45 (2) , 429-452
Direct Ambient Mass Spectrometry for Food, Beverage, and Agricultural Sample Analysis and Research
Ambient and direct mass spectrometry (MS) methods are becoming increasingly used for the rapid analysis of food, beverage and agricultural samples. Novel ionization approaches combined with targeted, or untargeted workflows provide analytical outcomes within a greatly reduced time period compared to traditional separation science coupled with MS detection. This review will provide an overview of atmospheric pressure ionization MS based techniques for analysis of food, beverage and agricultural samples, with an emphasis on direct and rapid analysis including ambient ionization. The review will be completed through presentation of relevant examples of the use of ambient ionization techniques for food and beverage analysis along with the authors perspectives for future challenges relevant to the field.
- 2 July 2025
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 45 (2) , 429-452
Open AccessDirect Ambient Mass Spectrometry for Food, Beverage, and Agricultural Sample Analysis and Research
Ambient and direct mass spectrometry (MS) methods are becoming increasingly used for the rapid analysis of food, beverage and agricultural samples. Novel ionization approaches combined with targeted, or untargeted workflows provide analytical outcomes within a greatly reduced time period compared to traditional separation science coupled with MS detection. This review will provide an overview of atmospheric pressure ionization MS based techniques for analysis of food, beverage and agricultural samples, with an emphasis on direct and rapid analysis including ambient ionization. The review will be completed through presentation of relevant examples of the use of ambient ionization techniques for food and beverage analysis along with the authors perspectives for future challenges relevant to the field.
- Open Access
Three-Dimensional Zeolitic Imidazolate Framework-8 as Sorbent Integrated with Active Capillary Plasma Mass Spectrometry for Rapid Assessment of Low-Level Wine and Grape Quality-Related Volatiles
The most commonly used methods to chemically assess grape and wine quality with high sensitivity and selectivity require lengthy analysis time and can be resource intensive. Here, we developed a rapid and non-destructive method that would help in grading and decision support. In this work, we demonstrate that integrating a three-dimensional (3D) material for volatile sampling with mass spectrometry detection can be used to sample grapes for phytosanitary, quality or smoke-taint assessments at low levels of marker compounds. An efficient zeolitic imidazolate framework-8 (ZIF-8) material was synthesised in situ on nickel foam (NF), taking advantage of its ultrahigh surface area, structural diversity, and functionality as an emerging nanostructured material for preconcentrating low-level wine and grape quality-related volatiles. When used as a sorbent in thermal desorption tubes and coupled directly to active capillary mass spectrometry, the average signal across the selected analytes increased by ~50% as compared to Tenax TA, a commercially available polymer, in a measurement that takes less than two minutes. The first integration of 3D materials into mass spectrometry opens new possibilities for developing new material architecture with enhanced selectivity of next-generation multifunctional instrumentation for volatile analysis and product quality assessment.
Open AccessThree-Dimensional Zeolitic Imidazolate Framework-8 as Sorbent Integrated with Active Capillary Plasma Mass Spectrometry for Rapid Assessment of Low-Level Wine and Grape Quality-Related Volatiles
The most commonly used methods to chemically assess grape and wine quality with high sensitivity and selectivity require lengthy analysis time and can be resource intensive. Here, we developed a rapid and non-destructive method that would help in grading and decision support. In this work, we demonstrate that integrating a three-dimensional (3D) material for volatile sampling with mass spectrometry detection can be used to sample grapes for phytosanitary, quality or smoke-taint assessments at low levels of marker compounds. An efficient zeolitic imidazolate framework-8 (ZIF-8) material was synthesised in situ on nickel foam (NF), taking advantage of its ultrahigh surface area, structural diversity, and functionality as an emerging nanostructured material for preconcentrating low-level wine and grape quality-related volatiles. When used as a sorbent in thermal desorption tubes and coupled directly to active capillary mass spectrometry, the average signal across the selected analytes increased by ~50% as compared to Tenax TA, a commercially available polymer, in a measurement that takes less than two minutes. The first integration of 3D materials into mass spectrometry opens new possibilities for developing new material architecture with enhanced selectivity of next-generation multifunctional instrumentation for volatile analysis and product quality assessment.
- Open Access
Rapid In-Field Volatile Sampling for Detection of Botrytis cinerea Infection in Wine Grapes
Fungal infection of grape berries (Vitis vinifera) by Botrytis cinerea frequently coincides with harvest, impacting both the yield and quality of grape and wine products. A rapid and non-destructive method for identifying B. cinerea infection in grapes at an early stage prior to harvest is critical to manage loss. In this study, zeolitic imidazolate framework-8 (ZIF-8) crystal was applied as an absorbent material for volatile extraction from B. cinerea infected and healthy grapes in a vineyard, followed by thermal desorption gas chromatography–mass spectrometry. The performance of ZIF-8 in regard to absorbing and trapping the targeted volatiles was evaluated with a standard solution of compounds and with a whole bunch of grapes enclosed in a glass container to maintain standard sampling conditions. The results from the sampling methods were then correlated to B. cinerea infection in grapes, as measured and determined by genus-specific antigen quantification. Trace levels of targeted compounds reported as markers of grape B. cinerea infection were successfully detected with in-field sampling. The peak area counts for volatiles 3-octanone, 1-octen-3-one, 3-octanol, and 1-octen-3-ol extracted using ZIF-8 were significantly higher than values achieved using Tenax®-TA from field testing and demonstrated good correlation with B. cinerea infection severities determined by B. cinerea antigen detection.
Open AccessRapid In-Field Volatile Sampling for Detection of Botrytis cinerea Infection in Wine Grapes
Fungal infection of grape berries (Vitis vinifera) by Botrytis cinerea frequently coincides with harvest, impacting both the yield and quality of grape and wine products. A rapid and non-destructive method for identifying B. cinerea infection in grapes at an early stage prior to harvest is critical to manage loss. In this study, zeolitic imidazolate framework-8 (ZIF-8) crystal was applied as an absorbent material for volatile extraction from B. cinerea infected and healthy grapes in a vineyard, followed by thermal desorption gas chromatography–mass spectrometry. The performance of ZIF-8 in regard to absorbing and trapping the targeted volatiles was evaluated with a standard solution of compounds and with a whole bunch of grapes enclosed in a glass container to maintain standard sampling conditions. The results from the sampling methods were then correlated to B. cinerea infection in grapes, as measured and determined by genus-specific antigen quantification. Trace levels of targeted compounds reported as markers of grape B. cinerea infection were successfully detected with in-field sampling. The peak area counts for volatiles 3-octanone, 1-octen-3-one, 3-octanol, and 1-octen-3-ol extracted using ZIF-8 were significantly higher than values achieved using Tenax®-TA from field testing and demonstrated good correlation with B. cinerea infection severities determined by B. cinerea antigen detection.
- Open Access
- 1 June 2023
- Published by MDPI AG in Preprints.org
Rapid In-Field Volatile Sampling for Detection and Quantification of Botrytis cinerea Infection in Wine Grapes
Fungal infection of grape berries (Vitis vinifera) by Botrytis cinerea frequently coincides with harvest, impacting both the yield and quality of grape and wine products. A rapid and non-destructive method for identifying B. cinerea infection in grapes at an early stage prior to harvest is critical to manage loss. In this study, zeolitic imidazolate framework-8 (ZIF-8) crystal was applied as an absorbent material for volatile extraction from B. cinerea-infected and healthy grapes in a vineyard followed by thermal desorption gas chromatography-mass spectrometry. The performance of ZIF-8 to absorb and trap targeted volatiles was evaluated with a standard solution of compounds and with a whole bunch of grapes enclosed in a glass container to maintain standard sampling conditions. Results from sampling methods were then correlated to B. cinerea infection in grapes as measured and determined by Genus specific antigen quantification. Trace levels of targeted compounds reported as markers of grape B. cinerea infection were successfully detected with in-field sampling. Peak area counts for volatiles 3-octanone, 1-octen-3-one, 3-octanol, and 1-octen-3-ol extracted using ZIF-8 were significantly higher than values achieved using Tenax®-TA from field testing and demonstrated good correlation with B. cinerea infection severities determined by B. cinerea antigen detection.
- 1 June 2023
- Published by MDPI AG in Preprints.org
Open AccessRapid In-Field Volatile Sampling for Detection and Quantification of Botrytis cinerea Infection in Wine Grapes
Fungal infection of grape berries (Vitis vinifera) by Botrytis cinerea frequently coincides with harvest, impacting both the yield and quality of grape and wine products. A rapid and non-destructive method for identifying B. cinerea infection in grapes at an early stage prior to harvest is critical to manage loss. In this study, zeolitic imidazolate framework-8 (ZIF-8) crystal was applied as an absorbent material for volatile extraction from B. cinerea-infected and healthy grapes in a vineyard followed by thermal desorption gas chromatography-mass spectrometry. The performance of ZIF-8 to absorb and trap targeted volatiles was evaluated with a standard solution of compounds and with a whole bunch of grapes enclosed in a glass container to maintain standard sampling conditions. Results from sampling methods were then correlated to B. cinerea infection in grapes as measured and determined by Genus specific antigen quantification. Trace levels of targeted compounds reported as markers of grape B. cinerea infection were successfully detected with in-field sampling. Peak area counts for volatiles 3-octanone, 1-octen-3-one, 3-octanol, and 1-octen-3-ol extracted using ZIF-8 were significantly higher than values achieved using Tenax®-TA from field testing and demonstrated good correlation with B. cinerea infection severities determined by B. cinerea antigen detection.
- Open Access
- 11 April 2023
- Published by Elsevier in Food Chemistry
- Vol. 421, 136120
Detection and prediction of Botrytis cinerea infection levels in wine grapes using volatile analysis
- 11 April 2023
- Published by Elsevier in Food Chemistry
- Vol. 421, 136120
Open AccessDetection and prediction of Botrytis cinerea infection levels in wine grapes using volatile analysis
- 21 February 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (6) , 4468-4474
Nanosecond Pulsed Dielectric Barrier Discharge Ionization Mass Spectrometry
Dielectric barrier discharge ionization (DBDI) is an emerging technique for ionizing volatile molecules directly from complex mixtures for sensitive detection by mass spectrometry (MS). In conventional DBDI, a high frequency and high voltage waveform with pulse widths of ~50 μs (and ~50 μs between pulses) is applied across a dielectric barrier and a gas to generate ‘low temperature plasma.’ Although such a source has the advantages of being compact, economical, robust and sensitive, background ions from the ambient environment can be formed in high abundances, which limits performance. Here, we demonstrate that high voltage pulse widths as narrow as 100 ns with a pulse-to-pulse delay of ~900 µs can significantly reduce background chemical noise and increase ion signal. Compared microsecond pulses, ~800 ns pulses can be used to increase the signal-to-noise and signal-to-background chemical noise ratios in DBDI-MS by up to 172% and 1300% for six analytes, including dimethyl methylphosphonate (DMMP), 3-octanone, and perfluorooctanoic acid. Using nanosecond pulses, the detection limit for DMMP and PFOA in human blood plasma can be lowered by more than a factor of two in comparison to microsecond pulses. In ‘nanopulsed’ plasma ionization, the extent of internal energy deposition is as low or lower than in electrospray ionization and micropulsed plasma ionization based on thermometer ion measurements. Overall, nanosecond high-voltage pulsing can be used to significantly improve the performance of DBDI-MS and potentially other ion sources involving high voltage waveforms.
- 21 February 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (6) , 4468-4474
Nanosecond Pulsed Dielectric Barrier Discharge Ionization Mass Spectrometry
Dielectric barrier discharge ionization (DBDI) is an emerging technique for ionizing volatile molecules directly from complex mixtures for sensitive detection by mass spectrometry (MS). In conventional DBDI, a high frequency and high voltage waveform with pulse widths of ~50 μs (and ~50 μs between pulses) is applied across a dielectric barrier and a gas to generate ‘low temperature plasma.’ Although such a source has the advantages of being compact, economical, robust and sensitive, background ions from the ambient environment can be formed in high abundances, which limits performance. Here, we demonstrate that high voltage pulse widths as narrow as 100 ns with a pulse-to-pulse delay of ~900 µs can significantly reduce background chemical noise and increase ion signal. Compared microsecond pulses, ~800 ns pulses can be used to increase the signal-to-noise and signal-to-background chemical noise ratios in DBDI-MS by up to 172% and 1300% for six analytes, including dimethyl methylphosphonate (DMMP), 3-octanone, and perfluorooctanoic acid. Using nanosecond pulses, the detection limit for DMMP and PFOA in human blood plasma can be lowered by more than a factor of two in comparison to microsecond pulses. In ‘nanopulsed’ plasma ionization, the extent of internal energy deposition is as low or lower than in electrospray ionization and micropulsed plasma ionization based on thermometer ion measurements. Overall, nanosecond high-voltage pulsing can be used to significantly improve the performance of DBDI-MS and potentially other ion sources involving high voltage waveforms.
- Open Access
- 12 September 2017
- Published by CSIRO Publishing in Australian Journal of Chemistry
- Vol. 70 (11) , 1219-1226
Internal Energy Deposition in Dielectric Barrier Discharge Ionization is Significantly Lower than in Direct Analysis in Real-Time Mass Spectrometry*
The extent of internal energy deposition using three different plasma-based ionization mass spectrometry (MS) methods, atmospheric pressure chemical ionization (APCI), direct analysis in real time (DART), and active capillary dielectric barrier discharge ionization (DBDI), was investigated using benzylammonium ‘thermometer’ ions. Ions formed by DBDI were activated significantly less than those that were formed by DART and APCI under these conditions. Thermal ion activation by DART can be reduced slightly by positioning the DART source further from the capillary entrance to the MS and reducing the heat that is applied to metastable atoms exiting the DART source. For example, the average ion internal energy distribution decreased by less than 10 % (166.9 ± 0.3 to 152.2 ± 1.0 kJ mol-1) when the distance between the DART source and the MS was increased by 250 % (10 to 25 mm). By lowering the DART temperature from 350 to 150°C, the internal energy distributions of the thermometer ions decreased by ~15 % (169.93 ± 0.83 to 150.21 ± 0.52 kJ mol-1). Positioning the DART source nozzle more than 25 mm from the entrance to the MS and decreasing the DART temperature further resulted in a significant decrease in ion signal. Thus, varying the major DART ion source parameters had minimal impact on the ‘softness’ of the DART ion source under these conditions. Overall, these data indicate that DBDI can be a significantly ‘softer’ ion source than two of the most widely used plasma-based ion sources that are commercially available.
- 12 September 2017
- Published by CSIRO Publishing in Australian Journal of Chemistry
- Vol. 70 (11) , 1219-1226
Open AccessInternal Energy Deposition in Dielectric Barrier Discharge Ionization is Significantly Lower than in Direct Analysis in Real-Time Mass Spectrometry*
The extent of internal energy deposition using three different plasma-based ionization mass spectrometry (MS) methods, atmospheric pressure chemical ionization (APCI), direct analysis in real time (DART), and active capillary dielectric barrier discharge ionization (DBDI), was investigated using benzylammonium ‘thermometer’ ions. Ions formed by DBDI were activated significantly less than those that were formed by DART and APCI under these conditions. Thermal ion activation by DART can be reduced slightly by positioning the DART source further from the capillary entrance to the MS and reducing the heat that is applied to metastable atoms exiting the DART source. For example, the average ion internal energy distribution decreased by less than 10 % (166.9 ± 0.3 to 152.2 ± 1.0 kJ mol-1) when the distance between the DART source and the MS was increased by 250 % (10 to 25 mm). By lowering the DART temperature from 350 to 150°C, the internal energy distributions of the thermometer ions decreased by ~15 % (169.93 ± 0.83 to 150.21 ± 0.52 kJ mol-1). Positioning the DART source nozzle more than 25 mm from the entrance to the MS and decreasing the DART temperature further resulted in a significant decrease in ion signal. Thus, varying the major DART ion source parameters had minimal impact on the ‘softness’ of the DART ion source under these conditions. Overall, these data indicate that DBDI can be a significantly ‘softer’ ion source than two of the most widely used plasma-based ion sources that are commercially available.
- 9 November 2016
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 28 (4) , 575-578
Effects of Different Waveforms on the Performance of Active Capillary Dielectric Barrier Discharge Ionization Mass Spectrometry
Active capillary dielectric barrier discharge ionization (DBDI) is emerging as a compact, low-cost, and robust method to form intact ions of small molecules for detection in near real time by porta...
- 9 November 2016
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 28 (4) , 575-578
Effects of Different Waveforms on the Performance of Active Capillary Dielectric Barrier Discharge Ionization Mass Spectrometry
Active capillary dielectric barrier discharge ionization (DBDI) is emerging as a compact, low-cost, and robust method to form intact ions of small molecules for detection in near real time by porta...
- Open Access
- 14 March 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (12) , 3714-3721
Solid-phase microextraction low temperature plasma mass spectrometry for the direct and rapid analysis of chemical warfare simulants in complex mixtures
Solid-phase microextraction (SPME) is directly integrated with low temperature plasma ionisation mass spectrometry to rapidly detect organophosphate chemical warfare agent simulants and their hydrolysis products in chemical mixtures, including urine. In this sampling and ionization method, the fibre serves: (i) to extract molecules from their native environment, and (ii) as the ionization electrode that is used to desorb and ionize molecules directly from the SPME surface. By use of a custom fabricated SPME fibre consisting of a stainless steel needle coated with a Linde Type A (LTA) zeolitic microporous material and low temperature plasma mass spectrometry, protonated dimethyl methylphosphonate (DMMP), diethyl ethylphosphonate (DEEP) and pinacolyl methylphosphonic acid (PinMPA) can be detected at less than 100 ppb directly in water and urine. Organophosphates were not readily detected by this approach using an uncoated needle in negative control experiments. The use of the LTA coating significantly outperformed the use of a high alumina Zeolite Socony Mobil-5 (ZSM-5) coating of comparable thickness that is significantly less polar than LTA. By conditioning the LTA probe by immersion in an aqueous CuSO4 solution, the ion abundance for protonated DMMP increased by more than 300% compared to that obtained without any conditioning. Sample recovery values were between 96 and 100% for each analyte. The detection of chemical warfare agent analogues and hydrolysis products required less than 2 min per sample. A key advantage of this sampling and ionization method is that analyte ions can be directly and rapidly sampled from chemical mixtures, such as urine and seawater, without sample preparation or chromatography for sensitive detection by mass spectrometry. This ion source should prove beneficial for portable mass spectrometry applications because relatively low detection limits can be obtained without the use of compressed gases, fluid pumps, and lasers. Moreover, the ion source is compact, can be powered with a 10 V battery, and is tolerant of complex mixtures.
- 14 March 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (12) , 3714-3721
Open AccessSolid-phase microextraction low temperature plasma mass spectrometry for the direct and rapid analysis of chemical warfare simulants in complex mixtures
Solid-phase microextraction (SPME) is directly integrated with low temperature plasma ionisation mass spectrometry to rapidly detect organophosphate chemical warfare agent simulants and their hydrolysis products in chemical mixtures, including urine. In this sampling and ionization method, the fibre serves: (i) to extract molecules from their native environment, and (ii) as the ionization electrode that is used to desorb and ionize molecules directly from the SPME surface. By use of a custom fabricated SPME fibre consisting of a stainless steel needle coated with a Linde Type A (LTA) zeolitic microporous material and low temperature plasma mass spectrometry, protonated dimethyl methylphosphonate (DMMP), diethyl ethylphosphonate (DEEP) and pinacolyl methylphosphonic acid (PinMPA) can be detected at less than 100 ppb directly in water and urine. Organophosphates were not readily detected by this approach using an uncoated needle in negative control experiments. The use of the LTA coating significantly outperformed the use of a high alumina Zeolite Socony Mobil-5 (ZSM-5) coating of comparable thickness that is significantly less polar than LTA. By conditioning the LTA probe by immersion in an aqueous CuSO4 solution, the ion abundance for protonated DMMP increased by more than 300% compared to that obtained without any conditioning. Sample recovery values were between 96 and 100% for each analyte. The detection of chemical warfare agent analogues and hydrolysis products required less than 2 min per sample. A key advantage of this sampling and ionization method is that analyte ions can be directly and rapidly sampled from chemical mixtures, such as urine and seawater, without sample preparation or chromatography for sensitive detection by mass spectrometry. This ion source should prove beneficial for portable mass spectrometry applications because relatively low detection limits can be obtained without the use of compressed gases, fluid pumps, and lasers. Moreover, the ion source is compact, can be powered with a 10 V battery, and is tolerant of complex mixtures.