Application of Cortical Bone Plate Allografts Combined with Less Invasive Stabilization System (LISS) Plates in Fixation of Comminuted Distal Femur Fractures
Open Access
Abstract
Background and Objectives: At present, the management of comminuted distal femur fractures remains challenging for orthopedic surgeons. The aim of this study is to report a surgical treatment for comminuted distal femur fractures using supplementary medial cortical bone plate allografts in conjunction with the lateral less invasive stabilization system (LISS) plates. Materials and Methods: From January 2009 to January 2014, the records of thirty-three patients who underwent supplementary medial cortical bone plate allografts combined with lateral LISS plates fixation were reviewed. Clinical and radiographic data were collected during regular postoperative follow-up visits. Functional outcomes were determined according to the special surgery knee rating scale (HSS) used at the hospital. Results: Thirty patients were followed for 13 to 73 months after surgery, with an average follow-up time of 31.3 months. The mean time to bone union was 5.4 months (range of 3–12 months) and the mean range of knee flexion was 105.6° (range of 80–130°). Of the remaining patients, 10 had a score of “Excellent”, while 10 had a score of “Good”. Three patients had superficial or deep infections, one patient had nonunion that required bone grafting, and one patient had post-traumatic knee arthritis. Conclusions: Based on these promising results, we propose that supplementary medial cortical bone plate allografts combined with lateral LISS plate fixation may be a good treatment option for comminuted distal femur fractures. This treatment choice not only resulted in markedly improved stability on the medial side of the femur, but also satisfactory outcomes for distal femoral fractures.Keywords
Funding Information
- General Program of PLA Nanjing Military Area Command (20XLS21)
This publication has 28 references indexed in Scilit:
- Are Locking Constructs in Distal Femoral Fractures Always Best? A Prospective Multicenter Randomized Controlled Trial Comparing the Less Invasive Stabilization System With the Minimally Invasive Dynamic Condylar Screw SystemJournal of Orthopaedic Trauma, 2016
- Bone Marrow Aspirate Concentrate in Animal Long Bone HealingJournal of Orthopaedic Trauma, 2016
- Biomechanical analysis of distal femoral fracture fixation: dynamic condylar screw versus locked compression plateJournal of Orthopaedic Science, 2014
- Highly unstable complex C3-type distal femur fracture: can double plating via a modified Olerud extensile approach be a standby solution?Journal of Orthopaedics and Traumatology, 2012
- Antegrade Interlocking Nailing for Distal Femoral FracturesJournal of Orthopaedic Surgery, 2012
- Lower limb malrotation following MIPO technique of distal femoral and proximal tibial fracturesInjury, 2011
- The clinical and radiological outcomes of the LISS plate for distal femoral fractures: A systematic reviewInjury, 2009
- Fracture and Dislocation Classification Compendium - 2007Journal of Orthopaedic Trauma, 2007
- Epidemiology of adult fractures: A reviewInjury, 2006
- RETROGRADE NAILING VERSUS FIXED‐ANGLE BLADE PLATING FOR SUPRACONDYLAR FEMORAL FRACTURES: A RANDOMIZED CONTROLLED TRIALAnz Journal of Surgery, 2006