Feasibility of asymmetric flow field-flow fractionation coupled to ICP-MS for the characterization of wear metal particles and metalloproteins in biofluids from hip replacement patients
- 15 April 2015
- journal article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (16) , 4541-4554
Abstract
Hip replacements are used to improve the quality of life of people with orthopaedic conditions, but the use of metal-on-metal (MoM) arthroplasty has led to poor outcomes for some patients. These problems are related to the generation of micro- to nanosized metal wear particles containing Cr, Co or other elements, but the current analytical methods used to investigate the processes involved do not provide sufficient information to understand the size or composition of the wear particles generated in vivo. In this qualitative feasibility study, asymmetric flow field-flow fractionation (AF4) coupled with inductively coupled plasma mass spectrometry (ICP-MS) was used to investigate metal protein binding and the size and composition of wear metal particles present in serum and hip aspirates from MoM hip replacement patients. A well-established HPLC anion exchange chromatography (AEC) separation system coupled to ICP-MS was used to confirm the metal–protein associations in the serum samples. Off-line single particle ICP-MS (spICP-MS) analysis was used to confirm the approximate size distribution indicated by AF4 of the wear particles in hip aspirates. In the serum samples, AF4 –ICP-MS suggested that Cr was associated with transferrin (Tf) and Co with albumin (Alb) and an unidentified species; AEC–ICP-MS confirmed these associations and also indicated an association of Cr with Alb. In the hip aspirate sample, AF4–ICP-MS suggested that Cr was associated with Alb and Tf and that Co was associated with Alb and two unidentified compounds; AEC analysis confirmed the Cr results and the association of Co with Alb and a second compound. Enzymatic digestion of the hip aspirate sample, followed by separation using AF4 with detection by UV absorption (280 nm), multi-angle light scattering and ICP-MS, suggested that the sizes of the Cr-, Co- and Mo-containing wear particles in a hip aspirate sample were in the range 40–150 nm. Off-line spICP-MS was used to confirm these findings for the Co- and Cr-containing nanoparticles. Whilst limited in scope, the results are sufficient to show the interaction of ions with transport proteins and give an indication of particle size, providing useful pathological indices. As such, the methods indicate a new way forward for in vivo investigation of the processes which lead to tissue necrosis and hip loosening in patients with MoM hip replacements.Keywords
This publication has 18 references indexed in Scilit:
- Detection and characterization of silver nanoparticles in chicken meat by asymmetric flow field flow fractionation with detection by conventional or single particle ICP-MSAnalytical and Bioanalytical Chemistry, 2013
- Metal release from hip prostheses: cobalt and chromium toxicity and the role of the clinical laboratoryClinical Chemistry and Laboratory Medicine (CCLM), 2012
- Chemical speciation of nanoparticles surrounding metal-on-metal hipsChemical Communications, 2012
- Clinical usefulness of blood metal measurements to assess the failure of metal-on-metal hip implantsAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2012
- Diagnosing and investigating adverse reactions in metal on metal hip implantsBMJ, 2011
- Comparative assessment of implantable hip devices with different bearing surfaces: systematic appraisal of evidenceBMJ, 2011
- Separation and characterization of nanoparticles in complex food and environmental samples by field-flow fractionationTrAC Trends in Analytical Chemistry, 2011
- The chemical form of metallic debris in tissues surrounding metal-on-metal hips with unexplained failureActa Biomaterialia, 2010
- Metal release in patients with total hip arthroplasty by DF-ICP-MS and their association to serum proteinsJournal of Analytical Atomic Spectrometry, 2009
- Orthopaedic metals and their potential toxicity in the arthroplasty patientThe Journal of Bone and Joint Surgery. British volume, 2007