Semi-automatic segmentation of elongated interventional instruments for online calibration of C-arm imaging system
Open Access
- 26 June 2025
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (9) , 1-14
Abstract
Purpose: The C-arm biplane imaging system, designed for cerebral angiography, detects pathologies like aneurysms using dual rotating detectors for high-precision, real-time vascular imaging. However, accuracy can be affected by source-detector trajectory deviations caused by gravitational artifacts and mechanical instabilities. This study addresses calibration challenges and suggests leveraging interventional devices with radio-opaque markers to optimize C-arm geometry. Methods: We propose an online calibration method using image-specific features derived from interventional devices like guidewires and catheters (In the remainder of this paper, the term”catheter” will refer to both catheter and guidewire). The process begins with gantry-recorded data, refined through iterative nonlinear optimization. A machine learning approach detects and segments elongated devices by identifying candidates via thresholding on a weighted sum of curvature, derivative, and high-frequency indicators. An ensemble classifier segments these regions, followed by post-processing to remove false positives, integrating vessel maps, manual correction and identification markers. An interpolation step filling gaps along the catheter. Results: Among the optimized ensemble classifiers, the one trained on the first frames achieved the best performance, with a specificity of 99.43% and precision of 86.41%. The calibration method was evaluated on three clinical datasets and four phantom angiogram pairs, reducing the mean backprojection error from 4.11 ± 2.61 to 0.15 ± 0.01 mm. Additionally, 3D accuracy analysis showed an average root mean square error of 3.47% relative to the true marker distance. Conclusions: This study explores using interventional tools with radio-opaque markers for C-arm self-calibration. The proposed method significantly reduces 2D backprojection error and 3D RMSE, enabling accurate 3D vascular reconstruction.Keywords
This publication has 23 references indexed in Scilit:
- Self-calibration of C-arm imaging system using interventional instruments during an intracranial biplane angiographyInternational Journal of Computer Assisted Radiology and Surgery, 2022
- The optimization of parameters and matching point pairs in the 3D reconstruction of coronary arteryBiomedical Signal Processing and Control, 2021
- Fully Automatic and Real-Time Catheter Segmentation in X-Ray Fluoroscopy2017
- Geometry calibration method for a cone‐beam CT systemMedical Physics, 2017
- Automatic Guide-Wire Detection for Neurointerventions Using Low-Rank Sparse Matrix Decomposition and Denoising2015
- Guide-Wire Extraction through Perceptual Organization of Local Segments in Fluoroscopic Images2010
- Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysmsEuropean Radiology, 2000
- Multiscale vessel enhancement filtering1998
- New algorithm for QT interval analysis in 24-hour Holter ECG: performance and applicationsMedical & Biological Engineering & Computing, 1990
- The Levenberg-Marquardt algorithm: Implementation and theory1978