Oliver Beuing
Oliver Beuing has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bernhard Preim
Otto-von-Guericke-University, Magdeburg, Germany
2 shared publications - Negar Chabi
Department of Engineering Sciences, Jade Hochschule Wilhelmshaven, 26389 Wilhelmshaven, Germany
2 shared publications - Alfredo Illanes
Faculty of Computer Science and Research Campus STIMULATE, Otto-von-Guericke University, Universitätsplatz 2, 39106 Magdeburg, Germany
1 shared publication - Daniel Behme
Clinic for Neuroradiology, University Hospital of Magdeburg, Magdeburg, Germany
1 shared publication - Domenico Iuso
2imec-Vision Lab, University of Antwerp, Universiteitsplein 1, Antwerpen B-2610, Belgium
1 shared publication - Sylvia Saalfeld
Institute for Medical Informatics and Artificial Intelligence, University Hospital Schleswig-Holstein, 24105 Kiel, Germany
1 shared publication
Latest Publications
- Open Access
- 26 June 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (9) , 1-14
Semi-automatic segmentation of elongated interventional instruments for online calibration of C-arm imaging system
Purpose: The C-arm biplane imaging system, designed for cerebral angiography, detects pathologies like aneurysms using dual rotating detectors for high-precision, real-time vascular imaging. However, accuracy can be affected by source-detector trajectory deviations caused by gravitational artifacts and mechanical instabilities. This study addresses calibration challenges and suggests leveraging interventional devices with radio-opaque markers to optimize C-arm geometry. Methods: We propose an online calibration method using image-specific features derived from interventional devices like guidewires and catheters (In the remainder of this paper, the term”catheter” will refer to both catheter and guidewire). The process begins with gantry-recorded data, refined through iterative nonlinear optimization. A machine learning approach detects and segments elongated devices by identifying candidates via thresholding on a weighted sum of curvature, derivative, and high-frequency indicators. An ensemble classifier segments these regions, followed by post-processing to remove false positives, integrating vessel maps, manual correction and identification markers. An interpolation step filling gaps along the catheter. Results: Among the optimized ensemble classifiers, the one trained on the first frames achieved the best performance, with a specificity of 99.43% and precision of 86.41%. The calibration method was evaluated on three clinical datasets and four phantom angiogram pairs, reducing the mean backprojection error from 4.11 ± 2.61 to 0.15 ± 0.01 mm. Additionally, 3D accuracy analysis showed an average root mean square error of 3.47% relative to the true marker distance. Conclusions: This study explores using interventional tools with radio-opaque markers for C-arm self-calibration. The proposed method significantly reduces 2D backprojection error and 3D RMSE, enabling accurate 3D vascular reconstruction.
- 26 June 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (9) , 1-14
Open AccessSemi-automatic segmentation of elongated interventional instruments for online calibration of C-arm imaging system
Purpose: The C-arm biplane imaging system, designed for cerebral angiography, detects pathologies like aneurysms using dual rotating detectors for high-precision, real-time vascular imaging. However, accuracy can be affected by source-detector trajectory deviations caused by gravitational artifacts and mechanical instabilities. This study addresses calibration challenges and suggests leveraging interventional devices with radio-opaque markers to optimize C-arm geometry. Methods: We propose an online calibration method using image-specific features derived from interventional devices like guidewires and catheters (In the remainder of this paper, the term”catheter” will refer to both catheter and guidewire). The process begins with gantry-recorded data, refined through iterative nonlinear optimization. A machine learning approach detects and segments elongated devices by identifying candidates via thresholding on a weighted sum of curvature, derivative, and high-frequency indicators. An ensemble classifier segments these regions, followed by post-processing to remove false positives, integrating vessel maps, manual correction and identification markers. An interpolation step filling gaps along the catheter. Results: Among the optimized ensemble classifiers, the one trained on the first frames achieved the best performance, with a specificity of 99.43% and precision of 86.41%. The calibration method was evaluated on three clinical datasets and four phantom angiogram pairs, reducing the mean backprojection error from 4.11 ± 2.61 to 0.15 ± 0.01 mm. Additionally, 3D accuracy analysis showed an average root mean square error of 3.47% relative to the true marker distance. Conclusions: This study explores using interventional tools with radio-opaque markers for C-arm self-calibration. The proposed method significantly reduces 2D backprojection error and 3D RMSE, enabling accurate 3D vascular reconstruction.
- Open Access
- 12 March 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (7) , 1355-1366
Self-calibration of C-arm imaging system using interventional instruments during an intracranial biplane angiography
Purpose: To create an accurate 3D reconstruction of the vascular trees, it is necessary to know the exact geometrical parameters of the angiographic imaging system. Many previous studies used vascular structures to estimate the system’s exact geometry. However, utilizing interventional devices and their relative features may be less challenging, as they are unique in different views. We present a semi-automatic self-calibration approach considering the markers attached to the interventional instruments to estimate the accurate geometry of a biplane X-ray angiography system for neuroradiologic use. Methods: A novel approach is proposed to detect and segment the markers using machine learning classification, a combination of support vector machine and boosted tree. Then, these markers are considered as reference points to optimize the acquisition geometry iteratively. Results: The method is evaluated on four clinical datasets and three pairs of phantom angiograms. The mean and standard deviation of backprojection error for the catheter or guidewire before and after self-calibration are $$7.13\pm 6.47$$ mm and $$0.10\pm 0.06$$ mm, respectively. The mean and standard deviation of the 3D root-mean-square error (RMSE) for some markers in the phantom reduced from $$0.51\pm 0.11$$ to $$0.31\pm 0.08$$ mm. Conclusion: A semi-automatic approach to estimate the accurate geometry of the C-arm system was presented. Results show the reduction in the 2D backprojection error as well as the 3D RMSE after using our proposed self-calibration technique. This approach is essential for 3D reconstruction of the vascular trees or post-processing techniques of angiography systems that rely on accurate geometry parameters.- 12 March 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (7) , 1355-1366
Open AccessSelf-calibration of C-arm imaging system using interventional instruments during an intracranial biplane angiography
Purpose: To create an accurate 3D reconstruction of the vascular trees, it is necessary to know the exact geometrical parameters of the angiographic imaging system. Many previous studies used vascular structures to estimate the system’s exact geometry. However, utilizing interventional devices and their relative features may be less challenging, as they are unique in different views. We present a semi-automatic self-calibration approach considering the markers attached to the interventional instruments to estimate the accurate geometry of a biplane X-ray angiography system for neuroradiologic use. Methods: A novel approach is proposed to detect and segment the markers using machine learning classification, a combination of support vector machine and boosted tree. Then, these markers are considered as reference points to optimize the acquisition geometry iteratively. Results: The method is evaluated on four clinical datasets and three pairs of phantom angiograms. The mean and standard deviation of backprojection error for the catheter or guidewire before and after self-calibration are $$7.13\pm 6.47$$ mm and $$0.10\pm 0.06$$ mm, respectively. The mean and standard deviation of the 3D root-mean-square error (RMSE) for some markers in the phantom reduced from $$0.51\pm 0.11$$ to $$0.31\pm 0.08$$ mm. Conclusion: A semi-automatic approach to estimate the accurate geometry of the C-arm system was presented. Results show the reduction in the 2D backprojection error as well as the 3D RMSE after using our proposed self-calibration technique. This approach is essential for 3D reconstruction of the vascular trees or post-processing techniques of angiography systems that rely on accurate geometry parameters.