Bronchoscopy-related outbreaks and pseudo-outbreaks: A systematic review
- 15 December 2023
- journal article
- review article
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 45 (4) , 509-519
Abstract
Objective: To identify and report the pathogens and sources of contamination associated with bronchoscopy-related outbreaks and pseudo-outbreaks.Design: Systematic review.Setting: Inpatient and outpatient outbreaks and pseudo-outbreaks after bronchoscopy.Methods: PubMed/Medline databases were searched according to Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines, using the search terms “bronchoscopy,” “outbreak,” and “pseudo-outbreak” from inception until December 31, 2022. From eligible publications, data were extracted regarding the type of event, pathogen involved, and source of contamination. Pearson correlation was used to identify correlations between variables.Results: In total, 74 studies describing 23 outbreaks and 52 pseudo-outbreaks were included in this review. The major pathogens identified in these studies were Pseudomonas aeruginosa, Mycobacterium tuberculosis, nontuberculous mycobacteria (NTM), Klebsiella pneumoniae, Serratia marcescens, Stenotrophomonas maltophilia, Legionella pneumophila, and fungi. The primary sources of contamination were the use of contaminated water or contaminated topical anesthetics, dysfunction and contamination of bronchoscopes or automatic endoscope reprocessors, and inadequate disinfection of the bronchoscopes following procedures. Correlations were identified between primary bronchoscope defects and the identification of P. aeruginosa (r = 0.351; P = .002) and K. pneumoniae (r = 0.346; P = .002), and between the presence of a contaminated water source and NTM (r = 0.331; P = .004) or L. pneumophila (r = 0.280; P = .015).Conclusions: Continued vigilance in bronchoscopy disinfection practices remains essential because outbreaks and pseudo-outbreaks continue to pose a significant risk to patient care, emphasizing the importance of stringent disinfection and quality control measures.Keywords
This publication has 86 references indexed in Scilit:
- Caveat Emptor: The Role of Suboptimal Bronchoscope Repair Practices by a Third-Party Vendor in a Pseudo-Outbreak ofPseudomonasin Bronchoalveolar Lavage SpecimensInfection Control & Hospital Epidemiology, 2012
- Cluster of Pseudoinfections withBurkholderia cepaciaAssociated with a Contaminated Washer-Disinfector in a Bronchoscopy UnitInfection Control & Hospital Epidemiology, 2010
- Outbreak of Pseudomonas aeruginosa Infection Associated With Contamination of a Flexible BronchoscopeInfection Control & Hospital Epidemiology, 2009
- Pseudo-Outbreak ofLegionella pneumophilaSerogroup 8 Infection Associated With a Contaminated Ice Machine in a Bronchoscopy SuiteInfection Control & Hospital Epidemiology, 2009
- Epidemiologic, Clinical, and Economic Evaluation of an Outbreak of Clonal Multidrug-ResistantAcinetobacter baumanniiInfection in a Surgical Intensive Care UnitInfection Control & Hospital Epidemiology, 2007
- Dear Los Angeles TimesGastroenterology Nursing, 2004
- Pseudomonas aeruginosa and Serratia marcescens contamination associated with a manufacturing defect in bronchoscopes.Journal of Bronchology, 2003
- An outbreak of multidrug-resistant Pseudomonas aeruginosa infection associated with contamination of bronchoscopes and an endoscope washer-disinfectorJournal of Hospital Infection, 2000
- A pseudo-outbreak ofMethylobacterium mesophilica isolated from patients undergoing bronchoscopyEuropean Journal of Clinical Microbiology & Infectious Diseases, 1992
- Mycobacterial cross-contamination of bronchoscopy specimensJournal of Hospital Infection, 1988