Modified energy settings are mandatory to minimize oesophageal injury using the novel multipolar irrigated radiofrequency ablation catheter for pulmonary vein isolation
Open Access
- 23 October 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 17 (3) , 396-402
Abstract
The multipolar irrigated radiofrequency (RF) ablation catheter (nMARQ™) is a novel tool for pulmonary vein isolation (PVI). We investigated the incidence of thermal oesophageal injury (EI) using the nMARQ™ for PVI. In the initial six patients (Group 1), RF was delivered at the posterior wall with a maximum duration of 60 s and a maximum power (maxP) of 20 W for unipolar ablation, and a maxP of 10 W for the bipolar ablation. In the latter 15 patients (Group 2), RF application was limited at the posterior wall to a maximum duration of 30 s and a maxP of 15 W for unipolar ablation a max P of 10 W for bipolar ablation. Oesophageal temperature monitoring was performed in all patients and ablation was terminated at a temperature rise >41°C. Endoscopy was carried out within 2 days post-ablation. Pulmonary vein isolation was performed during sinus rhythm and was successfully achieved in 83 of 84 PVs except the septal inferior vein in one patient. Charring was seen in 3 of 21 (14.3%) patients without any evidence of embolism. Phrenic nerve palsy occurred in one patient. Endoscopy revealed severe EI in 3 of 6 (50%) patients in Group 1 and in 1 of 15 patients (6.7%) in Group 2. Procedure times between Groups 1 and 2 were similar (228.3 ± 60.2 min vs. 221.3 ± 51.8 min; P = 0.79). An unexpectedly high incidence of thermal EI was noted following PVI using the nMARQ™ with the initial ablation protocol. However, the incidence of thermal EI can be sigificantly reduced with limited power and RF application time at the posterior left atrium.Keywords
This publication has 17 references indexed in Scilit:
- Acute Safety and Efficacy of a Novel Multipolar Irrigated Radiofrequency Ablation Catheter for Pulmonary Vein IsolationJournal of Cardiovascular Electrophysiology, 2013
- Esophago‐pericardial Fistula Complicating Atrial Fibrillation Ablation Using a Novel Irrigated Radiofrequency Multipolar Ablation CatheterJournal of Cardiovascular Electrophysiology, 2013
- Catheter Ablation of Long-Standing Persistent Atrial FibrillationJACC, 2012
- 2012 focused update of the ESC Guidelines for the management of atrial fibrillationEP Europace, 2012
- Impact of pulmonary vein anatomy assessed by cardiac magnetic resonance imaging on endoscopic pulmonary vein isolation in consecutive patientsEP Europace, 2011
- Long-Term Results of Catheter Ablation in Paroxysmal Atrial FibrillationCirculation, 2010
- Utility of Esophageal Temperature Monitoring During Pulmonary Vein Isolation for Atrial Fibrillation Using Duty-Cycled Phased Radiofrequency AblationJournal of Cardiovascular Electrophysiology, 2010
- Area Under the Real‐Time Contact Force Curve (Force–Time Integral) Predicts Radiofrequency Lesion Size in an In Vitro Contractile ModelJournal of Cardiovascular Electrophysiology, 2010
- Oesophageal temperature monitoring and incidence of oesophageal lesions after pulmonary vein isolation using a remote robotic navigation systemEP Europace, 2010
- Incidence of oesophageal wall injury post-pulmonary vein antrum isolation for treatment of patients with atrial fibrillationEP Europace, 2008