TLTina Lin

Tina Lin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tina Lin has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • P-wave morphology and electrical activity of the isolated left atrial appendage on 12-lead ECG in patients with recurrent atrial tachyarrhythmias after pulmonary vein isolation

    by Tina Lin, Andreas Rillig, Andreas Metzner, Shibu Mathew, Christian Heeger, Peter Wohlmuth, Roland Tilz, Karl-Heinz Kuck, Feifan Ouyang

    Left atrial appendage isolation(LAAI) may occur during catheter ablation of complex atrial tachyarrhythmias(aTa). We compare P-waves before and after LAAI and characterize LAA activity on the 12-lead ECG after LAAI. Twenty-five patients were analyzed after LAAI. P-wave amplitude, duration, and morphology before and after LAAI were analyzed. Automaticity in the isolated LAA was identified, and magnified 12-lead surface ECGs were analyzed for LAA activity, amplitude, duration, and morphology. The isolated LAA area was measured using a 3D mapping system. P-wave amplitude and duration during sinus rhythm was 0.09 mV and 103.57 ms before LAAI and 0.09 mV and 102.25 ms after LAAI, respectively. Precordial leads, I, II, III, and aVF were positive. Lead aVR was negative. Lead aVL was −/+. There were no significant differences in P-wave morphology before and after LAAI. Twenty-one of 25 (84%) patients had LAA automaticity after LAAI. Twelve of 21 (57%) patients had automaticity associated with visible LAA activity on the surface ECG. The average LAA activity amplitude and duration was 0.02 mV and 67.7 ms, respectively. Precordial leads, I, II, III, and aVF were positive. Lead aVR was negative/isoelectric. Lead aVL was positive/isoelectric. The mean isolated LAA area was 29.1 cm2. The mean percentage area of isolated LAA vs total LA area was 22.6%. LAA activity can be visible on 12-lead ECG in 57% of patients after LAAI. They have smaller amplitudes and shorter durations compared to P-waves.


  • Cover Image, Volume 28, Issue 4

    by Roland Richard Tilz, Tina Lin, Andreas Rillig, Christian‐H. Heeger, Leonie Scholz, Peter Wohlmuth, Tudor Bucur, Andreas Metzner, Shibu Mathew, Erik Wissner, et al.

  • Focal impulse and rotor modulation using the novel 64-electrode basket catheter: electrogram characteristics of human rotors

    by Tina Lin, Andreas Rillig, Tudor Bucur, Andreas Metzner, Shibu Mathew, Erik Wissner, Peter Wohlmuth, Karl-Heinz Kuck, Feifan Ouyang, Roland Richard Tilz

    Aims Ablation of fractionated electrograms (EGMs) has been performed to eliminate areas of slow conduction in atrial fibrillation (AF). The rotor hypothesis suggests that rapidly activating spiral waves perpetuate and maintain AF. This study describes the EGM characteristics of AF rotors, using the novel 64-electrode basket catheter. Methods and results Twenty-five patients (male n = 16) with AF (paroxysmal n = 10) underwent focal impulse and rotor modulation. A 3.5 mm irrigated-tip ablation catheter was placed at the identified rotor core and EGMs were analysed for amplitude, characteristics (single-EGM, fractionated-EGM, and continuous-EGM), and cycle length over 10 s. A total of 72 rotors were identified [right atrium (RA) = 13, left atrium (LA) = 59]. Seven rotors were excluded from EGM analysis due to location in the pulmonary veins. Single-EGMs were more frequent in the RA compared with the LA (8 (61.5) vs. 12 (23.1); P < 0.01) and EGM amplitudes were smaller in LA rotors when compared with RA rotors (0.14 (0.08–0.17) mV vs. 0.19 (0.15–0.29) mV; P = 0.029). In patients with persistent AF, single-EGMs were observed more often in the right-sided rotors compared with left-sided rotors (4 (57.1) vs. 5 (14.3); P = 0.012), and EGM amplitudes were smaller in patients with persistent AF compared with paroxysmal atrial fibrillation (PAF) patients (0.15 (0.09–0.19) mV vs. 0.22 (0.17–0.47) mV; P = 0.03). Furthermore, the prevalence of fractionated- EGMs was higher in patients with persistent AF compared with PAF patients (31/42 (73.8) vs. 9/23 (39.1); P = 0.03). Conclusion There are no characteristic rotor-EGM potentials. Rotor-EGM characteristics are different between the RA and LA. Although rotors are not associated with abnormal EGMs, rotor-EGMs in persistent AF were more fractionated with lower amplitudes compared with that in PAF.


  • Open Access

    Modified energy settings are mandatory to minimize oesophageal injury using the novel multipolar irrigated radiofrequency ablation catheter for pulmonary vein isolation

    by Andreas Rillig, Tina Lin, Andre Burchard, Masashi Kamioka, Christian Heeger, Hisaki Makimoto, Andreas Metzner, Erik Wissner, Peter Wohlmuth, Feifan Ouyang, et al.

    The multipolar irrigated radiofrequency (RF) ablation catheter (nMARQ™) is a novel tool for pulmonary vein isolation (PVI). We investigated the incidence of thermal oesophageal injury (EI) using the nMARQ™ for PVI. In the initial six patients (Group 1), RF was delivered at the posterior wall with a maximum duration of 60 s and a maximum power (maxP) of 20 W for unipolar ablation, and a maxP of 10 W for the bipolar ablation. In the latter 15 patients (Group 2), RF application was limited at the posterior wall to a maximum duration of 30 s and a maxP of 15 W for unipolar ablation a max P of 10 W for bipolar ablation. Oesophageal temperature monitoring was performed in all patients and ablation was terminated at a temperature rise >41°C. Endoscopy was carried out within 2 days post-ablation. Pulmonary vein isolation was performed during sinus rhythm and was successfully achieved in 83 of 84 PVs except the septal inferior vein in one patient. Charring was seen in 3 of 21 (14.3%) patients without any evidence of embolism. Phrenic nerve palsy occurred in one patient. Endoscopy revealed severe EI in 3 of 6 (50%) patients in Group 1 and in 1 of 15 patients (6.7%) in Group 2. Procedure times between Groups 1 and 2 were similar (228.3 ± 60.2 min vs. 221.3 ± 51.8 min; P = 0.79). An unexpectedly high incidence of thermal EI was noted following PVI using the nMARQ™ with the initial ablation protocol. However, the incidence of thermal EI can be sigificantly reduced with limited power and RF application time at the posterior left atrium.