A Disposable Homemade Screen Printed Electrochemical Sensor for Vitamin B1 Determination in Multivitamin Ampoules: Potentiometric and Surface Morphology Studies
- 16 February 2017
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 29 (5) , 1426-1433
Abstract
Thiamine chloride hydrochloride (TCH) is one of the B‐complex vitamins which resemble a very biologically important group of biomolecules. The first screen‐printed graphite ion‐selective sensor for the determination of TCH was prepared and characterized. The sensor is based on TCH‐tetraphenylborate as electrode material. A number of parameters such as the type of solvent mediator, weight percent of the ion‐exchanger, test solution temperature and possible interferences were extensively studied. Moreover, the surface morphology of the prepared sensor was studied using scanning electron microscopy. The sensor shows a Nernstian slope of 30.60±0.07 mV/decade, a low LOD of 5.08×10−6 mol/L and a wide applicability range of 5.96×10−6‐1.00×10−2 mol/L. The sensing graphite ink remains usable for at least one month. Fast potentiometric response was obtained within 5 s and remains stable for at least 60 s. The sensor was applied to the analysis of TCH in pure solutions and multivitamin ampoules from the Egyptian market using the standard addition method and high recovery values of 97–102 % were obtained. Low %RSD values (0.27‐1.30) indicate high precision of the proposed sensor. Our sensor provides the advantages of disposability, simple preparation procedures, sensitivity and easy storage and transportation.Keywords
This publication has 18 references indexed in Scilit:
- A simple turn on fluorescent sensor for the selective detection of thiamine using coconut water derived luminescent carbon dotsBiosensors and Bioelectronics, 2016
- Determination of water-soluble vitamins in energy and sport drinks by micellar electrokinetic capillary chromatographyFood Control, 2016
- Recent Advances in Electroanalysis of VitaminsElectroanalysis, 2016
- Biological interaction of thiamine with lysozyme using binding capacity concept and molecular dockingJournal of Biomolecular Structure and Dynamics, 2016
- New voltammetric procedure for determination of thiamine in commercially available juices and pharmaceutical formulation using a lead film electrodeFood Chemistry, 2012
- Simultaneous determination of vitamin B1 and B2 in complex cereal foods, by reverse phase isocratic HPLC-UVJournal of Cereal Science, 2012
- Using PVC ion-selective electrodes for the potentiometric flow injection analysis of distigmine in its pharmaceutical formulation and biological fluidsJournal of Advanced Research, 2011
- SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF FOLIC ACID, PYRIDOXINE, RIBOFLAVIN, AND THIAMINE BY PARTIAL LEAST-SQUARES REGRESSIONAnalytical Letters, 2002
- Microdetermination of Vitamin B1 in the Presence of Vitamins B2, B6, and B12 by Solid-Phase UV SpectrophotometryAnalytical Chemistry, 1998
- Thiamine-reineckate liquid membrane electrode for the selective determination of thiamine (vitamin B1) in pharmaceutical preparationsThe Analyst, 1989