Yousry Moustafa Issa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yousry Moustafa Issa has a total of 271 co-authors. Here are the top co-authors by number of shared publications:
A. F. Shoukry
Chemistry Department, Faculty of Science, Cairo University
15 shared publicationsH. Khalifa
Chemistry Department, Faculty of Science, Cairo University, Giza, Egypt
11 shared publicationsAdel F. Shoukry
Chemistry Department, Faculty of Science, Cairo University, Giza, Egypt EG
10 shared publications- Sayed Imam Mohamed Zayed
Beni Suef University
8 shared publications Hosny Ibrahim
7 shared publicationsM. S. Rizk
7 shared publications
Latest Publications
- Open Access
- 20 September 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (10) , 778
A Core–Shell Au@TiO2 and Multi-Walled Carbon Nanotube-Based Sensor for the Electroanalytical Determination of H2O2 in Human Blood Serum and Saliva
A hydrogen peroxide (H2O2) sensor was developed based on core–shell gold@titanium dioxide nanoparticles and multi-walled carbon nanotubes modified glassy carbon electrode (Au@TiO2/MWCNTs/GCE). Core–shell Au@TiO2 material was prepared and characterized using a scanning electron microscopy and energy dispersive X-ray analysis (SEM/EDX), transmission electron microscopy (TEM), atomic force microscopy (AFM), Raman spectroscopy, X-ray diffraction (XRD) and Zeta-potential analyzer. The proposed sensor (Au@TiO2/MWCNTs/GCE) was investigated electrochemically using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The analytical performance of the sensor was evaluated towards H2O2 using differential pulse voltammetry (DPV). The proposed sensor exhibited excellent stability and sensitivity with a linear concentration range from 5 to 200 µM (R2 = 0.9973) and 200 to 6000 µM (R2 = 0.9994), and a limit of detection (LOD) of 1.4 µM achieved under physiological pH conditions. The practicality of the proposed sensor was further tested by measuring H2O2 in human serum and saliva samples. The observed response and recovery results demonstrate its potential for real-world H2O2 monitoring. Additionally, the proposed sensor and detection strategy can offer potential prospects in electrochemical sensors development, indicative oxidative stress monitoring, clinical diagnostics, general cancer biomarker measurements, paper bleaching, etc.
- 20 September 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (10) , 778
Open AccessA Core–Shell Au@TiO2 and Multi-Walled Carbon Nanotube-Based Sensor for the Electroanalytical Determination of H2O2 in Human Blood Serum and Saliva
A hydrogen peroxide (H2O2) sensor was developed based on core–shell gold@titanium dioxide nanoparticles and multi-walled carbon nanotubes modified glassy carbon electrode (Au@TiO2/MWCNTs/GCE). Core–shell Au@TiO2 material was prepared and characterized using a scanning electron microscopy and energy dispersive X-ray analysis (SEM/EDX), transmission electron microscopy (TEM), atomic force microscopy (AFM), Raman spectroscopy, X-ray diffraction (XRD) and Zeta-potential analyzer. The proposed sensor (Au@TiO2/MWCNTs/GCE) was investigated electrochemically using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The analytical performance of the sensor was evaluated towards H2O2 using differential pulse voltammetry (DPV). The proposed sensor exhibited excellent stability and sensitivity with a linear concentration range from 5 to 200 µM (R2 = 0.9973) and 200 to 6000 µM (R2 = 0.9994), and a limit of detection (LOD) of 1.4 µM achieved under physiological pH conditions. The practicality of the proposed sensor was further tested by measuring H2O2 in human serum and saliva samples. The observed response and recovery results demonstrate its potential for real-world H2O2 monitoring. Additionally, the proposed sensor and detection strategy can offer potential prospects in electrochemical sensors development, indicative oxidative stress monitoring, clinical diagnostics, general cancer biomarker measurements, paper bleaching, etc.
- 7 December 2020
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 45 (3) , 1482-1499
The synthesis, spectroscopic characterization, DFT/TD-DFT/PCM calculations of the molecular structure and NBO of the novel charge-transfer complexes of pyrazine Schiff base derivatives with aromatic nitro compounds
The novel charge-transfer (CT) solid complexes of pyrazine Schiff bases, derived from 2-aminopyrazine and substituted benzaldehydes (N-benzylidenepyrazin-2-amine, (NBPA)) and N-(((4-dimethylamino)benzylidene)pyrazin-2-amine) (NDMABPA) with some aromatic nitro compounds have been synthesized and characterized experimentally using ultraviolet-visible (UV-Vis) absorption, infrared spectra and proton nuclear magnetic resonance (1HNMR) spectroscopy. Complexes were formed in a molar ratio of 1 : 1 with good indications for the existence of charge-transfer in its molecular structure. Theoretical studies were done on donors and acceptors, elucidating their structures and active sites where the charge-transfer occurs. The experimental work was done in ethanol. Solution characterizations included the determination of the molecular structure of formed CT complexes, verifying the 1 : 1 (donor:acceptor) ratio in ethanol. The quantum mechanical calculations of geometries and energies were attained using the density functional theory with Becke's three parameter exchange functional method. The Lee–Yang–Parr correlation functional approach (B3LYP/DFT) combined with the 6-31G(d,p) basis set has been consecutively carried out in solution using ethanol as a solvent to compliment measured results, and to justify CT within donors and acceptors. The optimized energy, complexation energy, geometrical parameters, natural atomic charges, as well as the 3D-plots of the molecular electrostatic potential maps (MEP) were computed and elucidated. They agreed with the experimental results, wherein complex stabilities are attributed to the occurence of charge-transfer. The electronic spectra were computed and executed using time dependent-density functional theory (TD-DFT) via the addition of polarizable continuum solvation method PCM, PCM-TD-DFT. The allowed singlet transitions are positioned, and their highest occupied molecular orbital (HOMO) and lowest unoccupied molecular orbital (LUMO) involvement is represented. The descriptions of frontier HOMO and LUMO molecular orbitals attributed to the first four singlet transitions, are shown. For all formed solid complexes, the main relationship between donor and acceptor molecules is through the π–π* interaction. A secondary n–π* transition was noticed in some complexes. The vibrational wavenumbers were also determined using B3LYP/6-31G(d,p), and the results match with the experiment. The small energy gap between HOMO and LUMO energies indicate that CT occurs within donors and acceptors. The hyperconjugative interactions, molecular stability, bond strength and intramolecular CT have been investigated applying natural bond orbital (NBO) analysis. The mean polarizability, total static dipole moment, anisotropy of polarizability, and mean first-order hyperpolarizability have also been attained. The obtained values show that CT complexes are accomplished candidates to non-linear optical (NLO) materials.
- 7 December 2020
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 45 (3) , 1482-1499
The synthesis, spectroscopic characterization, DFT/TD-DFT/PCM calculations of the molecular structure and NBO of the novel charge-transfer complexes of pyrazine Schiff base derivatives with aromatic nitro compounds
The novel charge-transfer (CT) solid complexes of pyrazine Schiff bases, derived from 2-aminopyrazine and substituted benzaldehydes (N-benzylidenepyrazin-2-amine, (NBPA)) and N-(((4-dimethylamino)benzylidene)pyrazin-2-amine) (NDMABPA) with some aromatic nitro compounds have been synthesized and characterized experimentally using ultraviolet-visible (UV-Vis) absorption, infrared spectra and proton nuclear magnetic resonance (1HNMR) spectroscopy. Complexes were formed in a molar ratio of 1 : 1 with good indications for the existence of charge-transfer in its molecular structure. Theoretical studies were done on donors and acceptors, elucidating their structures and active sites where the charge-transfer occurs. The experimental work was done in ethanol. Solution characterizations included the determination of the molecular structure of formed CT complexes, verifying the 1 : 1 (donor:acceptor) ratio in ethanol. The quantum mechanical calculations of geometries and energies were attained using the density functional theory with Becke's three parameter exchange functional method. The Lee–Yang–Parr correlation functional approach (B3LYP/DFT) combined with the 6-31G(d,p) basis set has been consecutively carried out in solution using ethanol as a solvent to compliment measured results, and to justify CT within donors and acceptors. The optimized energy, complexation energy, geometrical parameters, natural atomic charges, as well as the 3D-plots of the molecular electrostatic potential maps (MEP) were computed and elucidated. They agreed with the experimental results, wherein complex stabilities are attributed to the occurence of charge-transfer. The electronic spectra were computed and executed using time dependent-density functional theory (TD-DFT) via the addition of polarizable continuum solvation method PCM, PCM-TD-DFT. The allowed singlet transitions are positioned, and their highest occupied molecular orbital (HOMO) and lowest unoccupied molecular orbital (LUMO) involvement is represented. The descriptions of frontier HOMO and LUMO molecular orbitals attributed to the first four singlet transitions, are shown. For all formed solid complexes, the main relationship between donor and acceptor molecules is through the π–π* interaction. A secondary n–π* transition was noticed in some complexes. The vibrational wavenumbers were also determined using B3LYP/6-31G(d,p), and the results match with the experiment. The small energy gap between HOMO and LUMO energies indicate that CT occurs within donors and acceptors. The hyperconjugative interactions, molecular stability, bond strength and intramolecular CT have been investigated applying natural bond orbital (NBO) analysis. The mean polarizability, total static dipole moment, anisotropy of polarizability, and mean first-order hyperpolarizability have also been attained. The obtained values show that CT complexes are accomplished candidates to non-linear optical (NLO) materials.
- Open Access
- 1 September 2017
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 10 (6) , 751-760
Potentiometric and surface topography studies of new carbon-paste sensors for determination of thiamine in Egyptian multivitamin ampoules
We report here for the first time two potentiometric carbon-paste sensors for determination of thiamine chloride hydrochloride in aqueous solutions. The proposed sensors use the ion-pair of thiamine with tetraphenylborate as an electro-active species and dibutyl phthalate (sensor I) or o-nitrophenyloctyl ether (sensor II) as solvent mediators. The effect of solvent mediator was studied using dibutyl phthalate, o-nitrophenyloctyl ether, ethylhexyl adipate, dioctyl phthalate, tricresyl phosphate and paraffin oil. The slopes of the calibration graphs are 29.49 ± 0.24 and 29.60 ± 0.15 mV/decade for sensors (I) and (II), respectively. The sensors are able to detect down to 5.25 × 10−6 and 3.57 × 10−6 for (I) and (II), respectively. Both sensors show reasonable thermal stability and fast response time. The selectivity coefficients obtained from the matched potential method indicate high selectivity of the proposed sensors toward thiamine over commonly interfering cations. Sensor (I) has a lifetime of only 1–2 days; however, sensor (II) remains usable for up to one month. Analytical applications to pure solutions and Egyptian multivitamin ampoules show excellent recovery values ranging from 97.92 to 103.72% and 97.21 to 102.19% for sensors (I) and (II), respectively. Moreover, the precision and reproducibility of the sensors are indicated from the low values of %RSD of five replicate measurements. In addition, the surface topography of the sensors was studied using scanning electron microscopy to investigate the effect of chemical modification on the surface structure
- 1 September 2017
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 10 (6) , 751-760
Open AccessPotentiometric and surface topography studies of new carbon-paste sensors for determination of thiamine in Egyptian multivitamin ampoules
We report here for the first time two potentiometric carbon-paste sensors for determination of thiamine chloride hydrochloride in aqueous solutions. The proposed sensors use the ion-pair of thiamine with tetraphenylborate as an electro-active species and dibutyl phthalate (sensor I) or o-nitrophenyloctyl ether (sensor II) as solvent mediators. The effect of solvent mediator was studied using dibutyl phthalate, o-nitrophenyloctyl ether, ethylhexyl adipate, dioctyl phthalate, tricresyl phosphate and paraffin oil. The slopes of the calibration graphs are 29.49 ± 0.24 and 29.60 ± 0.15 mV/decade for sensors (I) and (II), respectively. The sensors are able to detect down to 5.25 × 10−6 and 3.57 × 10−6 for (I) and (II), respectively. Both sensors show reasonable thermal stability and fast response time. The selectivity coefficients obtained from the matched potential method indicate high selectivity of the proposed sensors toward thiamine over commonly interfering cations. Sensor (I) has a lifetime of only 1–2 days; however, sensor (II) remains usable for up to one month. Analytical applications to pure solutions and Egyptian multivitamin ampoules show excellent recovery values ranging from 97.92 to 103.72% and 97.21 to 102.19% for sensors (I) and (II), respectively. Moreover, the precision and reproducibility of the sensors are indicated from the low values of %RSD of five replicate measurements. In addition, the surface topography of the sensors was studied using scanning electron microscopy to investigate the effect of chemical modification on the surface structure
- 17 August 2017
- Published by Wiley in Electroanalysis
- Vol. 29 (11) , 2541-2550
Tellurite Carbon Paste Sensors: Microscopic Analysis Provides New Insights on the Nature of the Interaction Between the Ionophore and Analytical Species
In this work, scanning electron microscopy (SEM) was used for the characterization of chemically modified carbon paste sensors (CMCPSs), with the aim of understanding their chemical and electrochemical properties. The work also provides a microscopic study on the role of the binder, type of carbon, amount and nature of modifier, composition of the carbon paste and its impact on the electrochemical performance of the sensor. In addition, energy dispersive X‐ray spectroscopy (EDX) was utilized for the direct observation of the interaction between the chemical modifier and the carbon paste. This has enabled the fabrication of new sensitive and selective chemically modified carbon paste sensors that were successfully applied for the detection of tellurite ions in pure solutions, environmental and biological samples. This work provides new insights on the rational design and integration of carbon paste sensors for a variety of applications.
- 17 August 2017
- Published by Wiley in Electroanalysis
- Vol. 29 (11) , 2541-2550
Tellurite Carbon Paste Sensors: Microscopic Analysis Provides New Insights on the Nature of the Interaction Between the Ionophore and Analytical Species
In this work, scanning electron microscopy (SEM) was used for the characterization of chemically modified carbon paste sensors (CMCPSs), with the aim of understanding their chemical and electrochemical properties. The work also provides a microscopic study on the role of the binder, type of carbon, amount and nature of modifier, composition of the carbon paste and its impact on the electrochemical performance of the sensor. In addition, energy dispersive X‐ray spectroscopy (EDX) was utilized for the direct observation of the interaction between the chemical modifier and the carbon paste. This has enabled the fabrication of new sensitive and selective chemically modified carbon paste sensors that were successfully applied for the detection of tellurite ions in pure solutions, environmental and biological samples. This work provides new insights on the rational design and integration of carbon paste sensors for a variety of applications.
- 15 May 2017
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 14 (9) , 1993-2005
Novel potentiometric sensors for pyrilamine maleate
- 15 May 2017
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 14 (9) , 1993-2005
Novel potentiometric sensors for pyrilamine maleate
- Open Access
- 1 April 2017
- Published by Elsevier in The Egyptian Journal of Remote Sensing and Space Sciences
- Vol. 20, S39-S48
Evaluation of Mariut Lake water quality using Hyperspectral Remote Sensing and laboratory works
- 1 April 2017
- Published by Elsevier in The Egyptian Journal of Remote Sensing and Space Sciences
- Vol. 20, S39-S48
Open AccessEvaluation of Mariut Lake water quality using Hyperspectral Remote Sensing and laboratory works
- Open Access
- 1 March 2017
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 10 (3) , 336-343
Solubilities and solubility products of clomipramine hydrochloride ion-associates with tetraphenylborate and silicotungstate
The solubility and solubility product of the two ion-associates clomipraminium tetraphenylborate (CLP-TPB) and silicotungstate ((CLP)4-ST) were determined using conductimetric and potentiometric measurements applying the standard addition method. The obtained values from both conductimetric measurements and standard addition method are close to each other. Thermodynamic parameters ΔG, ΔH and ΔS have been determined. Sodium tetraphenylborate has been used for the determination of CLP.Cl in model solution and pharmaceutical preparation by conductimetric titrations. The proposed method allowed the determination of CLP.Cl within the range of 0.17–35.15mg. The accuracy of the method is indicated by the excellent recovery 99.95–101.23%, and the precision is supported by the low relative standard deviation 0.50–1.21%. The ruggedness and robustness of the proposed method were also studied
- 1 March 2017
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 10 (3) , 336-343
Open AccessSolubilities and solubility products of clomipramine hydrochloride ion-associates with tetraphenylborate and silicotungstate
The solubility and solubility product of the two ion-associates clomipraminium tetraphenylborate (CLP-TPB) and silicotungstate ((CLP)4-ST) were determined using conductimetric and potentiometric measurements applying the standard addition method. The obtained values from both conductimetric measurements and standard addition method are close to each other. Thermodynamic parameters ΔG, ΔH and ΔS have been determined. Sodium tetraphenylborate has been used for the determination of CLP.Cl in model solution and pharmaceutical preparation by conductimetric titrations. The proposed method allowed the determination of CLP.Cl within the range of 0.17–35.15mg. The accuracy of the method is indicated by the excellent recovery 99.95–101.23%, and the precision is supported by the low relative standard deviation 0.50–1.21%. The ruggedness and robustness of the proposed method were also studied
- 16 February 2017
- Published by Wiley in Electroanalysis
- Vol. 29 (5) , 1426-1433
A Disposable Homemade Screen Printed Electrochemical Sensor for Vitamin B1 Determination in Multivitamin Ampoules: Potentiometric and Surface Morphology Studies
Thiamine chloride hydrochloride (TCH) is one of the B‐complex vitamins which resemble a very biologically important group of biomolecules. The first screen‐printed graphite ion‐selective sensor for the determination of TCH was prepared and characterized. The sensor is based on TCH‐tetraphenylborate as electrode material. A number of parameters such as the type of solvent mediator, weight percent of the ion‐exchanger, test solution temperature and possible interferences were extensively studied. Moreover, the surface morphology of the prepared sensor was studied using scanning electron microscopy. The sensor shows a Nernstian slope of 30.60±0.07 mV/decade, a low LOD of 5.08×10−6 mol/L and a wide applicability range of 5.96×10−6‐1.00×10−2 mol/L. The sensing graphite ink remains usable for at least one month. Fast potentiometric response was obtained within 5 s and remains stable for at least 60 s. The sensor was applied to the analysis of TCH in pure solutions and multivitamin ampoules from the Egyptian market using the standard addition method and high recovery values of 97–102 % were obtained. Low %RSD values (0.27‐1.30) indicate high precision of the proposed sensor. Our sensor provides the advantages of disposability, simple preparation procedures, sensitivity and easy storage and transportation.
- 16 February 2017
- Published by Wiley in Electroanalysis
- Vol. 29 (5) , 1426-1433
A Disposable Homemade Screen Printed Electrochemical Sensor for Vitamin B1 Determination in Multivitamin Ampoules: Potentiometric and Surface Morphology Studies
Thiamine chloride hydrochloride (TCH) is one of the B‐complex vitamins which resemble a very biologically important group of biomolecules. The first screen‐printed graphite ion‐selective sensor for the determination of TCH was prepared and characterized. The sensor is based on TCH‐tetraphenylborate as electrode material. A number of parameters such as the type of solvent mediator, weight percent of the ion‐exchanger, test solution temperature and possible interferences were extensively studied. Moreover, the surface morphology of the prepared sensor was studied using scanning electron microscopy. The sensor shows a Nernstian slope of 30.60±0.07 mV/decade, a low LOD of 5.08×10−6 mol/L and a wide applicability range of 5.96×10−6‐1.00×10−2 mol/L. The sensing graphite ink remains usable for at least one month. Fast potentiometric response was obtained within 5 s and remains stable for at least 60 s. The sensor was applied to the analysis of TCH in pure solutions and multivitamin ampoules from the Egyptian market using the standard addition method and high recovery values of 97–102 % were obtained. Low %RSD values (0.27‐1.30) indicate high precision of the proposed sensor. Our sensor provides the advantages of disposability, simple preparation procedures, sensitivity and easy storage and transportation.
- Open Access
- 1 September 2016
- Published by Elsevier in International Journal of Electrochemical Science
- Vol. 11 (9) , 7475-7498
Determination and Speciation of Tellurium Hazardous Species in Real and Environmental Samples
- 1 September 2016
- Published by Elsevier in International Journal of Electrochemical Science
- Vol. 11 (9) , 7475-7498
Open AccessDetermination and Speciation of Tellurium Hazardous Species in Real and Environmental Samples
- 1 September 2016
- Published by Elsevier in Measurement
- Vol. 91, 210-220
Implementation of spectroscopic techniques for characterization of icons of Deir El Sankoria, El Minia, Egypt
- 1 September 2016
- Published by Elsevier in Measurement
- Vol. 91, 210-220
Implementation of spectroscopic techniques for characterization of icons of Deir El Sankoria, El Minia, Egypt