A dose falloff gradient study in RapidArc planning of lung stereotactic body radiation therapy
Open Access
- 1 January 2018
- journal article
- research article
- Published by Medknow in Journal of Medical Physics
- Vol. 43 (3) , 147-154
Abstract
Introduction: Radiation Therapy Oncology Group (RTOG) report #0813 and 0915 recommends using D2cmand R50%as plan quality metrics for evaluation of normal tissue sparing in stereotactic body radiation therapy (SBRT) of lung lesion. This study introduces dose falloff gradient (DFG) as a tool for analyzing the dose beyond the planning target volume (PTV) extending into normal tissue structures. In ascertaining the impact of PTV size and SBRT planning techniques in DFG, this study questions the independence of the RTOG recommended metrics. Materials and Methods: In this retrospective study, 41 RapidArc lung SBRT plans with 2 or 3 complete or partial arcs were analyzed. PTV volumes ranged between 5.3 and 113 cm3 and their geographic locations were distributed in both lungs. 6MV, 6 MV-FFF, 10 MV, or 10 MV-FFF energies were used. RTOG-0915 metrics conformity index, homogeneity index, D2cm, R50%, and HDlocwere evaluated. DFG was computed from the mean and maximum dose in seven concentric 5 mm wide rings outside the PTV. DFG was investigated against the volume of normal lung irradiated by 50% isodose volume. Treatment plans with alternate energy and couch rotations were generated. Results: The dose falloff beyond PTV was modeled using a double exponential fit and evaluated for relationship with intermediate lung dose. Photon energy and beam configuration had a minimal impact on the dose falloff outside. The product of normalized D2cmand R50%was estimated to have a slowly varying value. Conclusions: Dose falloff outside PTV has been studied as a function of radial distance and ascertained by intermediate dose to normal lung. DFG can serve as a complementary plan quality metric.Keywords
This publication has 19 references indexed in Scilit:
- Optimising Stereotactic Body Radiotherapy for Non-small Cell Lung Cancer with Volumetric Intensity-modulated Arc Therapy—A Planning StudyClinical Oncology, 2012
- Volumetric-Modulated Arc Therapy for Stereotactic Body Radiotherapy of Lung Tumors: A Comparison With Intensity-Modulated Radiotherapy TechniquesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Volumetric modulated arc planning for lung stereotactic body radiotherapy using conventional and unflattened photon beams: a dosimetric comparison with 3D techniqueRadiation Oncology, 2011
- Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT)Radiation Oncology, 2011
- Stereotactic body radiation therapy: The report of AAPM Task Group 101Medical Physics, 2010
- Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity-modulated arcsRadiotherapy and Oncology, 2009
- Recommendations for implementing stereotactic radiotherapy in peripheral stage IA non-small cell lung cancer: report from the Quality Assurance Working Party of the randomised phase III ROSEL studyRadiation Oncology, 2009
- Automated non-coplanar beam direction optimization improves IMRT in SBRT of liver metastasisRadiotherapy and Oncology, 2008
- Excessive Toxicity When Treating Central Tumors in a Phase II Study of Stereotactic Body Radiation Therapy for Medically Inoperable Early-Stage Lung CancerJournal of Clinical Oncology, 2006
- Accreditation and quality assurance for Radiation Therapy Oncology Group: Multicenter clinical trials using Stereotactic Body Radiation Therapy in lung cancerActa Oncologica, 2006