A hand-operated microfluidic sample preparation-to-analysis workflow for simplifying the basophil activation test
- 27 June 2025
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (15) , 3779-3791
Abstract
Access to the basophil activation test (BAT) has been hindered by the requirement for fresh blood analysis, specialized laboratory equipment, and advanced technical expertise. To address these issues, we have developed a hand-operated microfluidic sample preparation “μF-prep” device to perform the most time sensitive steps of the assay and stabilize the sample, effectively extending the time window before flow cytometry analysis. The μF-prep device performs concurrent basophil stimulation and staining for eight conditions in parallel. Barcoded staining of basophils allows the pooling of all conditions into one lyse/fix buffer tube for sample stabilization. After flow cytometry analysis, an XGBoost-enabled analysis pipeline unpools the eight conditions and generates basophil counts and activation levels directly from raw flow cytometry data. To characterize the μF-prep device, we stimulate whole blood samples from peanut-allergic and non-allergic donors. We compare μF-prep with a conventional BAT sample preparation protocol (“conv-prep”), and assess the stability of stimulated samples stored in the lyse/fix buffer. The μF-prep device performs sample preparation with −1, maximum activation levels, area under the dose response curve, and EC50 values. Activation levels of basophils from anonymous and presumed non-allergic donors in samples stored in the lyse/fix buffer for up to 7 days at 4 °C are similar to those analyzed on day 0. In summary, we demonstrate the potential of μF-prep to facilitate access to the BAT by simplifying sample preparation, stabilizing samples to remove the need for overnight blood shipping for flow cytometry analysis, and automating the data analysis pipeline.Keywords
Funding Information
- National Institute of Allergy and Infectious Diseases (R21AI149277)
- National Institute of Allergy and Infectious Diseases (Project 4 U19AI104209)
- National Institute of Biomedical Imaging and Bioengineering (R21EB030643)
- Stanford Bio-X (R10-24)
- Stanford SystemX Alliance
- Wallace H. Coulter Foundation
- Stanford Byers Center for Biodesign
This publication has 68 references indexed in Scilit:
- Validation of inducible basophil biomarkers: Time, temperature and transportationCytometry Part B: Clinical Cytometry, 2021
- Diagnosis and Differential Diagnosis of Food Allergy2020
- CytoNorm: A Normalization Algorithm for Cytometry DataCytometry Part A, 2019
- Prevalence and Severity of Food Allergies Among US AdultsJAMA Network Open, 2019
- Basophil Activation Test: Old and New Applications in AllergyCurrent Allergy and Asthma Reports, 2018
- Data‐driven programmatic approach to analysis of basophil activation testsCytometry Part B: Clinical Cytometry, 2017
- Diagnosis of Food Allergy: Epicutaneous Skin Tests, In Vitro Tests, and Oral Food ChallengeCurrent Allergy and Asthma Reports, 2010
- CD203c‐based basophil activation test in allergy diagnosis: Characteristics and differences to CD63 upregulationCytometry Part B: Clinical Cytometry, 2010
- Basophil activation test by flow cytometry: Present and future applications in allergologyCytometry Part B: Clinical Cytometry, 2008
- Monitoring human basophil activation via CD63 monoclonal antibody 435Journal of Allergy and Clinical Immunology, 1991