Sindy Kam Yan Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sindy Kam Yan Tang has a total of 178 co-authors. Here are the top co-authors by number of shared publications:
- Ya Gai
Department of Mechanical Engineering, Stanford University, Stanford, CA 94305
9 shared publications Ming Pan
Department of Mechanical Engineering Tang Research Group Stanford University Stanford CA 94305 USA
8 shared publicationsKevin S. Zhang
Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
6 shared publicationsMinkyu Kim
Department of Mechanical Engineering, Stanford University, 440 Escondido Mall, Stanford, California 94305, United States
6 shared publicationsNicolas Castaño
Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
6 shared publications- Nicolas Castaño
Department of Mechanical Engineering Stanford University Stanford CA 94305 USA
6 shared publications
Latest Publications
- Open Access
- 21 September 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1) , 325
Code-multiplexed multi-frequency impedance cytometry with a unified deep-unfolding network
- 21 September 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1) , 325
Open AccessCode-multiplexed multi-frequency impedance cytometry with a unified deep-unfolding network
Multi‐Tiered µDicer Enables Protein‐Preserving Microdissection at 10 µm Resolution
Laser capture microdissection (LCM) remains the leading technology for isolating sub‐millimeter regions of interest (ROIs) to enable downstream molecular profiling and study tissue heterogeneity. As the ROI approaches cellular dimensions (∼10 µm), laser‐induced photothermal damage and challenges in capturing microtissues in conventional LCM can compromise protein preservation and quantitative fidelity. This work introduces multi‐tiered µDicers, fabricated by two‐photon polymerization, to mechanically dissect tissue slices into uniform microtissues down to 10 µm. The hierarchical blade architecture limits instantaneous blade‐tissue engagement and lowers the cutting force relative to single‐tier designs. For benchmarking, proteomic analysis is performed on ethanol‐fixed human squamous cell carcinoma microtissues generated by µDicers and by LCM. Under identical Nanodroplet Processing in One pot for Trace Samples (nanoPOTS) and liquid chromatography‐mass spectrometry (LC‐MS) conditions, µDicers yield more peptides and proteins than LCM, with the largest gains at 10–20 µm spatial resolution. Confocal imaging shows catapult‐associated cavities in LCM‐generated microtissues. This material loss, along with membrane‐limited protein extraction, likely reduces protein coverage. In contrast, multi‐tiered µDicers enable reproducible microdissection down to 10 µm while maintaining high protein coverage. With the spatial registration of microtissues under development, µDicers have the potential to complement LCM for next‐generation spatial proteomic workflows.
Multi‐Tiered µDicer Enables Protein‐Preserving Microdissection at 10 µm Resolution
Laser capture microdissection (LCM) remains the leading technology for isolating sub‐millimeter regions of interest (ROIs) to enable downstream molecular profiling and study tissue heterogeneity. As the ROI approaches cellular dimensions (∼10 µm), laser‐induced photothermal damage and challenges in capturing microtissues in conventional LCM can compromise protein preservation and quantitative fidelity. This work introduces multi‐tiered µDicers, fabricated by two‐photon polymerization, to mechanically dissect tissue slices into uniform microtissues down to 10 µm. The hierarchical blade architecture limits instantaneous blade‐tissue engagement and lowers the cutting force relative to single‐tier designs. For benchmarking, proteomic analysis is performed on ethanol‐fixed human squamous cell carcinoma microtissues generated by µDicers and by LCM. Under identical Nanodroplet Processing in One pot for Trace Samples (nanoPOTS) and liquid chromatography‐mass spectrometry (LC‐MS) conditions, µDicers yield more peptides and proteins than LCM, with the largest gains at 10–20 µm spatial resolution. Confocal imaging shows catapult‐associated cavities in LCM‐generated microtissues. This material loss, along with membrane‐limited protein extraction, likely reduces protein coverage. In contrast, multi‐tiered µDicers enable reproducible microdissection down to 10 µm while maintaining high protein coverage. With the spatial registration of microtissues under development, µDicers have the potential to complement LCM for next‐generation spatial proteomic workflows.
- Open Access
Code-Multiplexed Multi-Frequency Impedance Cytometry with a Unified Deep-Unfolding Network
Impedance flow cytometry (IFC) is a label-free, single-cell measurement technique that captures biophysical properties beyond traditional biochemical markers. Code-multiplexing allows parallelization of IFC with simple hardware but requires advanced signal processing algorithm to resolve overlaps in signals originating from different channels. Existing methods, however, rely on multiple task-specific networks with template-based linear fitting, which loses accuracy under nonlinear or unstable conditions common in microfluidic experiments. Prior studies have also been restricted to demultiplexing single-frequency impedance measurements. To this end, we develop a unified deep-unfolding network for analyzing code multiplexed, multi frequency IFC data. We unfold successive-interference cancellation (SIC) algorithm into a deep-learning network that encodes the structural priors of SIC, and enable a single multitask network to resolve overlaps while sharing information across tasks. To mitigate nonlinear signal stretching and amplification, our network recognizes events by predicting bit level intensity and duration. For multi-frequency impedance profiling, we apply least-squares fitting to the predicted single-frequency real-impedance trace to map the real and imaginary impedance traces at other frequencies. On the cell-bead mixture evaluation dataset, our pipeline resolves overlaps from singlets to triplets reliably, reconstructs impedance-intensity distributions accurately, and enables multi-frequency impedance profiling. As a demonstration of principle, we use our pipeline to perform label free quantification of basophil activation from code-multiplexed, multi-frequency IFC measurements. Consistent with previous study, impedance opacity correlates well with activation levels measured by fluorescence flow cytometry. In summary, our study demonstrates the feasibility and utility of a deep-unfolding network that extends code-multiplexed, multi-frequency IFC to label-free single-cell functional assays.
Open AccessCode-Multiplexed Multi-Frequency Impedance Cytometry with a Unified Deep-Unfolding Network
Impedance flow cytometry (IFC) is a label-free, single-cell measurement technique that captures biophysical properties beyond traditional biochemical markers. Code-multiplexing allows parallelization of IFC with simple hardware but requires advanced signal processing algorithm to resolve overlaps in signals originating from different channels. Existing methods, however, rely on multiple task-specific networks with template-based linear fitting, which loses accuracy under nonlinear or unstable conditions common in microfluidic experiments. Prior studies have also been restricted to demultiplexing single-frequency impedance measurements. To this end, we develop a unified deep-unfolding network for analyzing code multiplexed, multi frequency IFC data. We unfold successive-interference cancellation (SIC) algorithm into a deep-learning network that encodes the structural priors of SIC, and enable a single multitask network to resolve overlaps while sharing information across tasks. To mitigate nonlinear signal stretching and amplification, our network recognizes events by predicting bit level intensity and duration. For multi-frequency impedance profiling, we apply least-squares fitting to the predicted single-frequency real-impedance trace to map the real and imaginary impedance traces at other frequencies. On the cell-bead mixture evaluation dataset, our pipeline resolves overlaps from singlets to triplets reliably, reconstructs impedance-intensity distributions accurately, and enables multi-frequency impedance profiling. As a demonstration of principle, we use our pipeline to perform label free quantification of basophil activation from code-multiplexed, multi-frequency IFC measurements. Consistent with previous study, impedance opacity correlates well with activation levels measured by fluorescence flow cytometry. In summary, our study demonstrates the feasibility and utility of a deep-unfolding network that extends code-multiplexed, multi-frequency IFC to label-free single-cell functional assays.
- 29 October 2025
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 21 (42) , 8219-8230
Characterization of cellular wound resistance in the giant ciliate Stentor coeruleus
Stentor coeruleus resists wounding via cytoskeletal stiffness and cytoplasmic rheology. Cortical microtubule disruption compromises wound resistance, while shear-thinning cytoplasm enhances tolerance to hydrodynamic stress up to a critical threshold.
- 29 October 2025
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 21 (42) , 8219-8230
Characterization of cellular wound resistance in the giant ciliate Stentor coeruleus
Stentor coeruleus resists wounding via cytoskeletal stiffness and cytoplasmic rheology. Cortical microtubule disruption compromises wound resistance, while shear-thinning cytoplasm enhances tolerance to hydrodynamic stress up to a critical threshold.
- Open Access
- 2 October 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (40)
Geometrical compartmentalization of trigger waves
Trigger waves, self-regenerating fronts of biochemical activity that spread without losing speed or amplitude, are widespread in cell signaling. Apoptosis is one example of a process that propagates through the cytoplasm via trigger waves. Curiously, in some contexts, like synaptic pruning, apoptotic caspase activation is confined to specific subcellular regions. We hypothesized that at junctions between a thin cytoplasmic extension, like a dendritic spine, and a thicker one, like a dendrite, trigger wave propagation may be blocked even though diffusion is not, as a result of the general properties of trigger waves and bistable systems. This hypothesis was explored theoretically through modeling studies and dimensional arguments, which confirmed that trigger wave compartmentalization was possible and that the critical channel width required for compartmentalization was likely to be biologically relevant. These predictions were then tested experimentally with undiluted Xenopus egg extracts that were induced to undergo apoptosis. We found that channels that are less than a few microns in diameter are small enough to compartmentalize apoptosis, and that the critical width is inversely proportional to trigger wave speed. Thus, cellular projections and tubules can allow for the compartmentalization of biochemical states within a spatially continuous cytoplasm, a fundamental yet previously overlooked mechanism for controlling biochemical signaling and cellular functions.
- 2 October 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (40)
Open AccessGeometrical compartmentalization of trigger waves
Trigger waves, self-regenerating fronts of biochemical activity that spread without losing speed or amplitude, are widespread in cell signaling. Apoptosis is one example of a process that propagates through the cytoplasm via trigger waves. Curiously, in some contexts, like synaptic pruning, apoptotic caspase activation is confined to specific subcellular regions. We hypothesized that at junctions between a thin cytoplasmic extension, like a dendritic spine, and a thicker one, like a dendrite, trigger wave propagation may be blocked even though diffusion is not, as a result of the general properties of trigger waves and bistable systems. This hypothesis was explored theoretically through modeling studies and dimensional arguments, which confirmed that trigger wave compartmentalization was possible and that the critical channel width required for compartmentalization was likely to be biologically relevant. These predictions were then tested experimentally with undiluted Xenopus egg extracts that were induced to undergo apoptosis. We found that channels that are less than a few microns in diameter are small enough to compartmentalize apoptosis, and that the critical width is inversely proportional to trigger wave speed. Thus, cellular projections and tubules can allow for the compartmentalization of biochemical states within a spatially continuous cytoplasm, a fundamental yet previously overlooked mechanism for controlling biochemical signaling and cellular functions.
- 25 September 2025
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 447 (Pt 2)
Label-free, machine-learning assisted impedance assessment of basophil activation
- 25 September 2025
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 447 (Pt 2)
Label-free, machine-learning assisted impedance assessment of basophil activation
- 30 July 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (18) , 4677-4691
A lung tumor-on-a-chip model recapitulates the effect of hypoxia on radiotherapy response and FDG-PET imaging
A microfluidic tumor-on-a-chip platform reveals hypoxia-induced radioresistance and metabolic shifts via integrated PET imaging.
- 30 July 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (18) , 4677-4691
A lung tumor-on-a-chip model recapitulates the effect of hypoxia on radiotherapy response and FDG-PET imaging
A microfluidic tumor-on-a-chip platform reveals hypoxia-induced radioresistance and metabolic shifts via integrated PET imaging.
- Open Access
A Lung Tumor-on-a-Chip Model Recapitulates the Effect of Hypoxia on Radiotherapy Response and FDG-PET Imaging
Most solid tumors contain regions of hypoxia that pose a significant challenge to the efficacy of radiation therapy. This study introduces a novel 3D lung tumor-on-a-chip (ToC) model designed to replicate the hypoxic tumor microenvironment in vitro while also providing a platform for clinically relevant interventions such as radiotherapy and positron emission tomography (PET) imaging. To simulate the heterogeneous oxygen distribution found in tumors, the ToC model incorporates an oxygen gradient achieved through a straightforward chemical oxygen scavenging system. A unique innovation of this device is the integration of a thin scintillator plate, which enables high-resolution radioluminescence microscopy imaging of tumor metabolism under hypoxia and normoxia conditions using clinically approved PET tracers such as fluorodeoxyglucose (FDG). The response of this hypoxic model to radiation therapy (10 Gy X-ray) demonstrated ∼4-fold higher radioresistance compared to the normoxic ToC model, as assessed by colony formation potential. Additionally, DNA damage observed in the normoxic ToC model was ∼5-fold higher than that in the hypoxic model. Furthermore, the metabolic consumption of glucose was found to mirror the localization of hypoxia, validating the use of this biomarker for planning radiation therapy. The integration of high-resolution radionuclide imaging within ToC models enables on-chip PET imaging and facilitates oncology research and discovery, offering innovative capabilities for the preclinical testing of novel cancer therapies in a clinically relevant environment.
Open AccessA Lung Tumor-on-a-Chip Model Recapitulates the Effect of Hypoxia on Radiotherapy Response and FDG-PET Imaging
Most solid tumors contain regions of hypoxia that pose a significant challenge to the efficacy of radiation therapy. This study introduces a novel 3D lung tumor-on-a-chip (ToC) model designed to replicate the hypoxic tumor microenvironment in vitro while also providing a platform for clinically relevant interventions such as radiotherapy and positron emission tomography (PET) imaging. To simulate the heterogeneous oxygen distribution found in tumors, the ToC model incorporates an oxygen gradient achieved through a straightforward chemical oxygen scavenging system. A unique innovation of this device is the integration of a thin scintillator plate, which enables high-resolution radioluminescence microscopy imaging of tumor metabolism under hypoxia and normoxia conditions using clinically approved PET tracers such as fluorodeoxyglucose (FDG). The response of this hypoxic model to radiation therapy (10 Gy X-ray) demonstrated ∼4-fold higher radioresistance compared to the normoxic ToC model, as assessed by colony formation potential. Additionally, DNA damage observed in the normoxic ToC model was ∼5-fold higher than that in the hypoxic model. Furthermore, the metabolic consumption of glucose was found to mirror the localization of hypoxia, validating the use of this biomarker for planning radiation therapy. The integration of high-resolution radionuclide imaging within ToC models enables on-chip PET imaging and facilitates oncology research and discovery, offering innovative capabilities for the preclinical testing of novel cancer therapies in a clinically relevant environment.
- 27 June 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (15) , 3779-3791
A hand-operated microfluidic sample preparation-to-analysis workflow for simplifying the basophil activation test
Access to the basophil activation test (BAT) has been hindered by the requirement for fresh blood analysis, specialized laboratory equipment, and advanced technical expertise. To address these issues, we have developed a hand-operated microfluidic sample preparation “μF-prep” device to perform the most time sensitive steps of the assay and stabilize the sample, effectively extending the time window before flow cytometry analysis. The μF-prep device performs concurrent basophil stimulation and staining for eight conditions in parallel. Barcoded staining of basophils allows the pooling of all conditions into one lyse/fix buffer tube for sample stabilization. After flow cytometry analysis, an XGBoost-enabled analysis pipeline unpools the eight conditions and generates basophil counts and activation levels directly from raw flow cytometry data. To characterize the μF-prep device, we stimulate whole blood samples from peanut-allergic and non-allergic donors. We compare μF-prep with a conventional BAT sample preparation protocol (“conv-prep”), and assess the stability of stimulated samples stored in the lyse/fix buffer. The μF-prep device performs sample preparation with −1, maximum activation levels, area under the dose response curve, and EC50 values. Activation levels of basophils from anonymous and presumed non-allergic donors in samples stored in the lyse/fix buffer for up to 7 days at 4 °C are similar to those analyzed on day 0. In summary, we demonstrate the potential of μF-prep to facilitate access to the BAT by simplifying sample preparation, stabilizing samples to remove the need for overnight blood shipping for flow cytometry analysis, and automating the data analysis pipeline.
- 27 June 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (15) , 3779-3791
A hand-operated microfluidic sample preparation-to-analysis workflow for simplifying the basophil activation test
Access to the basophil activation test (BAT) has been hindered by the requirement for fresh blood analysis, specialized laboratory equipment, and advanced technical expertise. To address these issues, we have developed a hand-operated microfluidic sample preparation “μF-prep” device to perform the most time sensitive steps of the assay and stabilize the sample, effectively extending the time window before flow cytometry analysis. The μF-prep device performs concurrent basophil stimulation and staining for eight conditions in parallel. Barcoded staining of basophils allows the pooling of all conditions into one lyse/fix buffer tube for sample stabilization. After flow cytometry analysis, an XGBoost-enabled analysis pipeline unpools the eight conditions and generates basophil counts and activation levels directly from raw flow cytometry data. To characterize the μF-prep device, we stimulate whole blood samples from peanut-allergic and non-allergic donors. We compare μF-prep with a conventional BAT sample preparation protocol (“conv-prep”), and assess the stability of stimulated samples stored in the lyse/fix buffer. The μF-prep device performs sample preparation with −1, maximum activation levels, area under the dose response curve, and EC50 values. Activation levels of basophils from anonymous and presumed non-allergic donors in samples stored in the lyse/fix buffer for up to 7 days at 4 °C are similar to those analyzed on day 0. In summary, we demonstrate the potential of μF-prep to facilitate access to the BAT by simplifying sample preparation, stabilizing samples to remove the need for overnight blood shipping for flow cytometry analysis, and automating the data analysis pipeline.
- Open Access
Characterization of cellular wound resistance in the giant ciliate Stentor coeruleus
Resistance to mechanical stress is essential for cells to prevent wounding and maintain structural integrity. This capability is especially critical for free-living single-celled organisms, which routinely encounter mechanical stress from their natural habitats. We investigated Stentor coeruleus , a single-celled ciliate known for its remarkable wound repair capacity, as a model for studying mechanical wound resistance. While previous work focused on wound repair in Stentor , the structures that enable it to resist wounding remain poorly understood. We characterized how Stentor resisted mechanical stress during transit through a microfluidic constriction. Using high- speed imaging, we tracked the transit dynamics of the cells and linked them to wounding outcomes. Larger cells experienced longer transit times in the constriction and were more prone to rupture, often failing to recover shape due to membrane rupture and loss of cytoplasm. To elucidate the role of the Stentor cytoskeleton, we performed drug-mediated disruption of KM fibers, which are microtubule bundles in the Stentor cytoskeleton. Drug-treated cells exhibited an increased likelihood of membrane rupture at the constriction, implicating KM fibers in wound resistance. To investigate the resistance of Stentor cells to hydrodynamic stress, we injected the cells at increasing flow rates through the constriction. Interestingly, cells were more resistant to larger hydrodynamic stresses up to a threshold, potentially due to shear-thinning of the cytoplasm. Together, these results suggest that Stentor relies on both cytoskeletal architecture and cytoplasmic rheology to withstand mechanical stress, offering insights into cellular strategies for wound resistance in the absence of rigid extracellular structures.
Open AccessCharacterization of cellular wound resistance in the giant ciliate Stentor coeruleus
Resistance to mechanical stress is essential for cells to prevent wounding and maintain structural integrity. This capability is especially critical for free-living single-celled organisms, which routinely encounter mechanical stress from their natural habitats. We investigated Stentor coeruleus , a single-celled ciliate known for its remarkable wound repair capacity, as a model for studying mechanical wound resistance. While previous work focused on wound repair in Stentor , the structures that enable it to resist wounding remain poorly understood. We characterized how Stentor resisted mechanical stress during transit through a microfluidic constriction. Using high- speed imaging, we tracked the transit dynamics of the cells and linked them to wounding outcomes. Larger cells experienced longer transit times in the constriction and were more prone to rupture, often failing to recover shape due to membrane rupture and loss of cytoplasm. To elucidate the role of the Stentor cytoskeleton, we performed drug-mediated disruption of KM fibers, which are microtubule bundles in the Stentor cytoskeleton. Drug-treated cells exhibited an increased likelihood of membrane rupture at the constriction, implicating KM fibers in wound resistance. To investigate the resistance of Stentor cells to hydrodynamic stress, we injected the cells at increasing flow rates through the constriction. Interestingly, cells were more resistant to larger hydrodynamic stresses up to a threshold, potentially due to shear-thinning of the cytoplasm. Together, these results suggest that Stentor relies on both cytoskeletal architecture and cytoplasmic rheology to withstand mechanical stress, offering insights into cellular strategies for wound resistance in the absence of rigid extracellular structures.