On the improvement of indoor environmental quality, energy performance and costs for a commercial nearly zero-energy building
- 30 June 2021
- journal article
- research article
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 27 (8) , 1056-1074
Abstract
The compliance with the indoor environmental quality (IEQ) requirements should be considered when designing retrofit actions for the refurbishment of existing buildings. The research is aimed to reduce the imbalance between the visual and thermal domains through the improvement of different design parameters in compliance with the nearly zero-energy building (nZEB) requirements. The article proposes a novel approach based on the integrated lighting, thermal, and energy dynamic simulation, to evaluate the overall building performance according to energy saving, cost effectiveness, and IEQ multi-criteria. Different energy efficiency actions, in terms of insulation materials, glazing solutions, and control strategies of the solar shading devices, have been applied to an existing office building-type. The analysis shows the possibility to design the refurbishment of an existing building into a nZEB while ensuring visual and thermal comfort. However, the not negligible costs lead to an incompliance with the cost-effectiveness requirements.Keywords
This publication has 19 references indexed in Scilit:
- Optimization of the design of the primary school classrooms in terms of energy and daylight performance considering occupants’ thermal and visual comfortEnergy Reports, 2020
- Optimized Solutions For Thermal And Visual Comfort In The Design Of A Nearly Zero-Energy Building2020
- Transformation of an Office Building into a Nearly Zero Energy Building (nZEB): Implications for Thermal and Visual Comfort and Energy PerformanceEnergies, 2019
- Eco-feedback for thermal comfort and cost efficiency in a nearly zero-energy residence in Guilin, ChinaEnergy and Buildings, 2018
- NZEB, cost- and comfort-optimal retrofit solutions for an Italian Reference HotelEnergy Procedia, 2017
- Effects of louvers shading devices on visual comfort and energy demand of an office building. A case of studyEnergy Procedia, 2017
- Energy performance of windows in office buildings considering daylight integration and visual comfort in hot climatesEnergy and Buildings, 2015
- Thermal and Daylight Evaluation of Building ZonesEnergy Procedia, 2015
- The role of window glazing on daylighting and energy saving in buildingsRenewable and Sustainable Energy Reviews, 2015
- Influence of shading control patterns on the energy assessment of office spacesEnergy and Buildings, 2012