GLGiovanna De Luca

Giovanna De Luca

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Giovanna De Luca has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Calibrating the Dynamic Energy Simulation Model for an Existing Building: Lessons Learned from a Collective Exercise

    by Adriana Angelotti, Livio Mazzarella, Cristina Cornaro, Francesca Frasca, Alessandro Prada, Paolo Baggio, Ilaria Ballarini, Giovanna De Luca, Vincenzo Corrado

    Calibration of the existing building simulation model is key to correctly evaluating the energy savings that are achievable through retrofit. However, calibration is a non-standard phase where different approaches can possibly lead to different models. In this study, an existing residential building is simulated in parallel by four research groups with different dynamic simulation tools. Manual/automatic methodologies and basic/detailed measurement data sets are used. The calibration is followed by a validation on two evaluation periods. Monitoring data concerning the windows opening by the occupants are used to analyze the calibration outcomes. It is found that for a good calibration of a model of a well-insulated building, the absence of data regarding the users’ behavior is more critical than uncertainty on the envelope properties. The automatic approach is more effective in managing the model complexity and reaching a better performing calibration, as the RMSE relative to indoor temperature reaches 0.3 °C compared to 0.4–0.5 °C. Yet, a calibrated model’s performance is often poor outside the calibration period (RMSE increases up to 10.8 times), and thus, the validation is crucial to discriminate among multiple solutions and to refine them, by improving the users’ behavior modeling.


  • Open Access

    Accuracy of Simplified Modelling Assumptions on External and Internal Driving Forces in the Building Energy Performance Simulation

    by Giovanna De Luca, Franz Bianco Mauthe Degerfeld, Ilaria Ballarini, Vincenzo Corrado

    The recently issued EN ISO 52016-1 technical standard provides a new simplified dynamic method for the building energy performance assessment. Since an extensive validation of the EN ISO 52016-1 hourly method is still missing, the present work investigates the effect of the main modelling assumptions—related to the heat balance on the outdoor and the indoor envelope surfaces—on the building thermal behaviour. The model validation was carried out by assessing the accuracy variation consequent to the application of the EN ISO 52016-1 modelling assumptions to a detailed dynamic calculation tool (EnergyPlus). To guarantee a general validity of the outcomes, two buildings, two levels of thermal insulation, and two Italian climatic zones were considered, for a total of eight case studies. To explore different applications of the standard method, the analysis was performed both under a free-floating condition—to evaluate the accuracy of the model in predicting the indoor operative temperatures—and to assess the annual energy needs for space heating and cooling. Results show that the assumptions related to the definition of the external convective and the shortwave (solar) radiation heat transfer lead to non-negligible inaccuracies in the EN ISO 52016-1 hourly model.


  • On the improvement of indoor environmental quality, energy performance and costs for a commercial nearly zero-energy building

    by Giovanna De Luca, Ilaria Ballarini, Argun Paragamyan, Anna Pellegrino, Vincenzo Corrado

    The compliance with the indoor environmental quality (IEQ) requirements should be considered when designing retrofit actions for the refurbishment of existing buildings. The research is aimed to reduce the imbalance between the visual and thermal domains through the improvement of different design parameters in compliance with the nearly zero-energy building (nZEB) requirements. The article proposes a novel approach based on the integrated lighting, thermal, and energy dynamic simulation, to evaluate the overall building performance according to energy saving, cost effectiveness, and IEQ multi-criteria. Different energy efficiency actions, in terms of insulation materials, glazing solutions, and control strategies of the solar shading devices, have been applied to an existing office building-type. The analysis shows the possibility to design the refurbishment of an existing building into a nZEB while ensuring visual and thermal comfort. However, the not negligible costs lead to an incompliance with the cost-effectiveness requirements.


  • Open Access

    Transformation of an Office Building into a Nearly Zero Energy Building (nZEB): Implications for Thermal and Visual Comfort and Energy Performance

    by Ilaria Ballarini, Giovanna De Luca, Argun Paragamyan, Anna Pellegrino, Vincenzo Corrado

    Directive 2010/31/EU promotes the refurbishment of existing buildings to change them into nearly zero-energy buildings (nZEBs). Within this framework, it is of crucial importance to guarantee the best trade-off between energy performance and indoor environmental quality (IEQ). The implications of a global refurbishment scenario on thermal and visual comfort are assessed in this paper pertaining to an existing office building. The retrofit actions applied to achieve the nZEB target consist of a combination of envelope and technical building systems refurbishment measures, involving both HVAC and lighting. Energy and comfort calculations were carried out through dynamic simulation using Energy Plus and DIVA, for the thermal and visual performance assessments, respectively. The results point out that energy retrofit actions on the building envelope would lead to significant improvements in the thermal performance, regarding both energy savings (−37% of the annual primary energy for heating) and thermal comfort. However, a daylighting reduction would occur with a consequent higher electricity demand for lighting (36%). The research presents a detailed approach applicable to further analyses aimed at optimizing the energy efficiency measures in order to reduce the imbalance between visual and thermal comfort and to ensure the best performance in both domains.