Abstract
The long-term outcome of endovascular coiling of cerebral aneurysms is directly related to the packing density at the time of treatment. In general, the highest packing density achievable is only about 45% due to the quasirandom distribution of currently available coils within aneurysms. We investigated whether packing densities could be maximized via more ordered coil configurations. Three different coil configurations—circular loops, planar spirals, and spherical helices—were investigated. The packing densities achievable in maximally filling the volume of an exemplar human basilar aneurysm with each coil configuration were calculated numerically. Coil packing simulations were also carried out for aneurysms idealized as spheres over diameters ranging from 2 mm to 30 mm. The packing densities with the loop, spiral, and spherical helix configurations were 82%, 60%, and 73%, respectively, for the human aneurysm model; the numbers of coils required were 693, 34, and 13, respectively. Simulations within idealized aneurysms suggest that aneurysms cannot be packed to more than 91% with coils of constant circular cross section. The spherical helix configuration provides a constant packing density (coefficient of variation of 0.4%) over the range of aneurysm diameters studied as compared to the two other configurations (coefficients of variation of 9% and 8%). Coil configurations that allow for ordered filling of cerebral aneurysms can potentially provide packing densities that are twice those currently achieved. The spherical helix configuration seems to be the most technically feasible and stable configuration of the three coil types investigated.Keywords
This publication has 12 references indexed in Scilit:
- Endovascular Treatment of Large and Giant AneurysmsAmerican Journal of Neuroradiology, 2008
- THE EFFECT OF VASCULAR RECONSTRUCTION DEVICE-ASSISTED COILING ON PACKING DENSITY, EFFECTIVE NECK COVERAGE, AND ANGIOGRAPHIC OUTCOMENeurosurgery, 2007
- Complex-Shaped Platinum Coils for Brain Aneurysms: Higher Packing Density, Improved Biomechanical Stability, and Midterm Angiographic OutcomeAmerican Journal of Neuroradiology, 2007
- Packing Performance of GDC 360° Coils in Intracranial Aneurysms: A Comparison with Complex Orbit Coils and Helical GDC 10 Coils2007
- Influence of coil thickness on packing, re-opening and retreatment of intracranial aneurysms: a comparative study between two types of coilsNeurological Research, 2005
- Unruptured intracranial aneurysms treated by three-dimensional coil embolization: evaluation of the postoperative aneurysm occlusion volumeNeuroradiology, 2005
- Evaluation of Aneurysm Stability After Endovascular Embolization With Guglielmi Detachable Coils: Correlation Between Long-Term Stability and Volume Embolization RatioNeurologia medico-chirurgica, 2005
- A general advancing front technique for filling space with arbitrary objectsInternational Journal for Numerical Methods in Engineering, 2004
- Relation between Aneurysm Volume, Packing, and Compaction in 145 Cerebral Aneurysms Treated with CoilsRadiology, 2004
- Long-Term Angiographic Recurrences After Selective Endovascular Treatment of Aneurysms With Detachable CoilsStroke, 2003