BLBaruch B. Lieber

Baruch B. Lieber

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Baruch B. Lieber has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Numerical Investigation of Coil Configurations That Provide Ultrahigh Packing Density of Saccular Aneurysms

    by Chander Sadasivan, Baruch B. Lieber

    The long-term outcome of endovascular coiling of cerebral aneurysms is directly related to the packing density at the time of treatment. In general, the highest packing density achievable is only about 45% due to the quasirandom distribution of currently available coils within aneurysms. We investigated whether packing densities could be maximized via more ordered coil configurations. Three different coil configurations—circular loops, planar spirals, and spherical helices—were investigated. The packing densities achievable in maximally filling the volume of an exemplar human basilar aneurysm with each coil configuration were calculated numerically. Coil packing simulations were also carried out for aneurysms idealized as spheres over diameters ranging from 2 mm to 30 mm. The packing densities with the loop, spiral, and spherical helix configurations were 82%, 60%, and 73%, respectively, for the human aneurysm model; the numbers of coils required were 693, 34, and 13, respectively. Simulations within idealized aneurysms suggest that aneurysms cannot be packed to more than 91% with coils of constant circular cross section. The spherical helix configuration provides a constant packing density (coefficient of variation of 0.4%) over the range of aneurysm diameters studied as compared to the two other configurations (coefficients of variation of 9% and 8%). Coil configurations that allow for ordered filling of cerebral aneurysms can potentially provide packing densities that are twice those currently achieved. The spherical helix configuration seems to be the most technically feasible and stable configuration of the three coil types investigated.


  • The mixability of angiographic contrast with arterial blood

    by Baruch B. Lieber, Chander Sadasivan, Qing Hao, Jaehoon Seong, Liliana Cesar

    Angiographic contrast that is routinely injected into arteries is used not only to evaluate arterial geometry but also in many cases to assess perfusion. The authors conducted two experiments to examine the dispersion of angiographic contrast injected antegradely into an artery under conditions similar to those found in selective (carotid artery) or superselective (circle of Willis) angiography in order to determine the distance from the catheter tip at which the contrast can be considered fully mixed with the blood. A third experiment investigated whether the contrast once mixed with blood will separate from the mixture under the gravitational field due to a density mismatch. Experiment I--Under high-speed angiographic acquisition, a bolus of contrast was injected through a catheter along the flow direction of a blood analog fluid flowing through a straight, long, cylindrical tube. The variation in grayscale intensity along the length of the tube was acquired and modeled as the step response to a second-order system. The distance from the catheter tip at which the contrast mixes with the working fluid, the mixing length, was determined as the length along the tube after which the step response settles to within 3% of the steady state value. Experiment II--A bolus of angiographic contrast was injected at rates varying from 0.1 to 1 cc/s through three different catheter sizes in the left common carotid artery of three rabbits. The average cross-sectional grayscale intensity over one cardiac cycle was calculated at four locations along the artery: Immediately distal to the catheter tip, at location of maximum grayscale intensity, and at 10 and 20 arterial diameters from the catheter tip. The status of mixing within 10 arterial diameters was assessed by differences between the grayscale value at this location and that at the maximum and 20 arterial diameter location. Experiment III--Angiographic contrast was premixed by agitation in three separate vials containing normal saline, canine blood, and glycerol/distilled-water mixture. The vials were then stationed vertically and angiographic images obtained every 5 min for 1 h. The average intensity of contrast along the vertical length of each vial was obtained for every time point to record any changes in the distribution of contrast over time. The first experiment shows that angiographic contrast completely mixes with steady flowing blood analog fluid within about eight tube diameters of the injection site. The second experiment shows that contrast completely mixes with blood within ten arterial diameters under appropriate injection parameters. The third experiment shows that angiographic contrast does not separate from, or settle out of, contrast-carrying fluid mixtures for a period of 1 h. The results demonstrate that under typical injection conditions in the clinical setting, contrast issuing from the catheter completely mixes with the blood within ten artery diameters downstream of the catheter tip. Once mixed, it does not separate from the blood due to gravity.


  • An Original Flow Diversion Device for the Treatment of Intracranial Aneurysms

    by Chander Sadasivan, Liliana Cesar, Jaehoon Seong, Audrey Rakian, Qing Hao, Fermin O. Tio, Ajay K. Wakhloo, Baruch B. Lieber

    Background and Purpose— The potential for successful treatment of intracranial aneurysms by flow diversion is gradually being recognized in the clinical setting; however, the devices currently available (stents) are not designed for flow diversion. We evaluate the long-term response of an appropriately designed flow diversion device in producing thrombotic occlusion of experimental aneurysms. Methods— Three different configurations of an original flow diversion device were implanted across thirty elastase-induced aneurysm models in rabbits. Ten animals per device configuration were followed-up for 3 weeks (n=3), 3 months (n=3), or 6 months (n=4), and tissue explanted postsacrifice was sent for histology. The temporal variation in angiographic contrast intensity within each aneurysm was fitted with a mathematical model to quantify the alteration in local hemodynamics caused by the implanted device. A predictive index, called the washout coefficient, was constructed to estimate long-term aneurysm occlusion probabilities immediately after treatment with any flow diversion device. Results— The device with a porosity of 70% and pore density of 18 pores/mm 2 performed better at occluding aneurysms than devices with 70% porosity, 12 pores/mm 2 and 65% porosity, 14 pores/mm 2 . A value of the washout coefficient less than 30 predicted greater than 97% angiographic aneurysm occlusion over a period of 6 months with a sensitivity of 73% and specificity of 82%. Conclusions— The flow diversion devices effected successful and stable aneurysm occlusion. Pore density, rather than porosity, may be the critical factor modulating efficacy of such devices.


  • Treatment of Rabbit Elastase-Induced Aneurysm Models by Flow Diverters: Development of Quantifiable Indexes of Device Performance Using Digital Subtraction Angiography

    by Chander Sadasivan, Liliana Cesar, Jaehoon Seong, Ajay K. Wakhloo, Baruch B. Lieber

    It has been known for more than a decade that intracranial aneurysms can be successfully treated by deploying a porous meshed tube in the parent vessel of the aneurysm. Such devices are currently called flow diverters because they promote intraneurysmal flow stasis and thrombosis by diverting blood flow away from the aneurysm sac. The objective of this study was to use angiographic data to quantify and compare the performance of flow diverters of original design in successfully occluding an experimental aneurysm model. Three different configurations of a novel flow diverter with varying porosities and pore densities were implanted in 30 rabbit elastase-induced aneurysms. Temporal variations in angiographic contrast intensity within the aneurysms were fit to a mathematical model. Optimized model parameters were supplemented by the angiographic percentage aneurysm occlusion and an angiographic measure of device flexibility to derive composite scores of performance. Angiographic quantification further suggested a parameter, which could be employed to estimate long-term aneurysm occlusion probabilities immediately after treatment. Performance scores showed that the device with a porosity of 70% and pore density of 18 pores/mm2 performed better than devices with 65% porosity, 14 pores/mm2, and 70% porosity, 12 pores/mm2 with relative efficacies of 100%, 84%, and 76%, respectively. The pore density of flow diverters, rather than porosity, may thus be a critical factor modulating device efficacy. A value of the prognostic parameter of less than 30 predicted greater than 97% angiographic aneurysm occlusion over six months with a sensitivity of 73% and specificity of 82%.


  • Correlation Between Angiographic and Particle Image Velocimetry Quantifications of Flow Diverters in an In Vitro Model of Elastase-Induced Rabbit Aneurysms

    by Asher L. Trager, Chander Sadasivan, Jaehoon Seong, Baruch B. Lieber

    The rupture of a cerebral aneurysm can result in a hemorrhagic stroke. A flow diverter, which is a porous tubular mesh, can be placed across the neck of a cerebral aneurysm to induce the cessation of flow and initiate the formation of an intra-aneurysmal thrombus. By finding a correlation between particle image velocimetry (PIV) and digital subtraction angiography, a better assessment of how well an aneurysm is excluded from the parent artery can be made in the clinical setting. A model of a rabbit elastase-induced aneurysm was connected to a mock circulation loop. The model was then placed under angiography. Recorded angiograms were analyzed so that a contrast concentration-time curve based on the average grayscale intensity inside the aneurysm could be determined. That curve was then fitted to a mathematical model that quantifies the influence of convection and diffusion on contrast transport. Optimized parameters were correlated with the intraneurysmal mean kinetic energy measured by PIV in the same aneurysm model. A strong correlation was observed between the convection and diffusion time constants and the mean kinetic energy inside the aneurysm. Analyzing the flow of angiographic contrast into and out of the aneurysm after implantation of a flow diverter allows for prediction of the efficacy of the device in excluding the aneurysm. Correlating hydrodynamic measures obtained by angiography to those obtained by detailed techniques such as PIV increases confidence in such predictions.


  • A Novel Angiographic Methodology for the Quantification of Angiogenesis

    by Matthew J. Gounis, Baruch B. Lieber, Keith A. Webster, Ajay K. Wakhloo

    The objective is to develop a method to quantify the dynamic information of contrast transport using angiography for investigating angiogenic treatments. In the rabbit hindlimb ischemia model, contrast media transport was examined for both arteries and the microvasculature. Time histories of image intensity were constructed and modeled. The differences in contrast transport quantified by the parameters of the mathematical model were statistically compared between animals treated with an adenoviral vector that expressed vascular endothelial growth factor and untreated animals. The data reveal that after one week of ischemia, treated animals have a statistical increase in the number of large vessels that convect blood more efficiently. This analysis further shows a statistically significant increase in the angiographic blush in the treated animals. A methodology is described that offers the capability of examining the number and geometry of large arteries, the dynamics of contrast transport, and the amount of angiographic blush that is related to microvascular density. In therapeutic angiogenesis, numerous techniques are used to measure variables such as the angiographic score, capillary density, and regional blood flow. The analysis presented herein can offer information of these variables, and is transferable from the laboratory to the clinical arena.


  • In Vitro Evaluation of Flow Divertors in an Elastase-Induced Saccular Aneurysm Model in Rabbit

    by Jaehoon Seong, Ajay K. Wakhloo, Baruch B. Lieber

    Endovascular coiling is an acceptable treatment of intracranial aneurysms, yet long term follow-ups suggest that endovascular coiling fails to achieve complete aneurysm occlusions particularly in wide-neck and giant aneurysms. Placing of a stentlike device across the aneurysm neck may be sufficient to occlude the aneurysm by promoting intra-aneurysmal thrombosis; however, conclusive evidence of its efficacy is still lacking. In this study, we investigate in vitro the efficacy of custom designed flow divertors that will be subsequently implanted in a large cohort of animals. The aim of this study is to provide a detailed database against which in vivo results can be analyzed. Six custom designed flow divertors were fabricated and tested in vitro. The design matrix included three different porosities (75%, 70%, and 65%). For each porosity, there were two divertors with one having a nominal pore density double than that of the other. To quantify efficacy, the divertors were implanted in a compliant elastomeric model of an elastase-induced aneurysm model in rabbit and intra-aneurysmal flow changes were evaluated by particle image velocimetry (PIV). PIV results indicate a marked reduction in intra-aneurysmal flow activity after divertor implantation in the innominate artery across the aneurysm neck. The mean hydrodynamic circulation after divertor implantation was reduced to 14% or less of the mean circulation in the control and the mean intra-aneurysmal kinetic energy was reduced to 29% or less of its value in the control. The intra-aneurysmal wall shear rate in this model is low and implantation of the flow divertor did not change the wall shear rate magnitude appreciably. This in vitro experiment evaluates the characteristics of local flow phenomena such as hydrodynamic circulation, kinetic energy, wall shear rate, perforator flow, and changes of these parameters as a result of implantation of stentlike flow divertors in an elastomeric replica of elastase-induced saccular aneurysm model in rabbit. These initial findings offer a database for evaluation of in vivo implantations of such devices in the animal model and help in further development of cerebral aneurysm bypass devices.


  • Angiographic Assessment of the Performance of Flow Divertors to Treat Cerebral Aneurysms

    by Chander Sadasivan, Baruch B. Lieber, Liliana Cesar, Laszlo Miskolczi, Jaehoon Seong, Ajay K. Wakhloo

    Past clinical and experimental evidence suggests that cerebral aneurysms can be successfully excluded from the circulation solely by the endovascular placement of a flow diverting device across the aneurysm neck. These devices promote intraaneurysmal flow stasis and concomitant thrombosis by redirecting flow away from the aneurysm. To comprehensively test the efficacy of such flow divertors, we are implanting devices with three different porosities in a large cohort of elastase-induced aneurysms in rabbits. Treatment efficacy is quantified by a mathematical model that is fit to aneurysmal angiographic contrast washout curves. Results from three animals implanted with different device porosities are presented here. The model competently captures the behavior of the aneurysmal washout curves and provides reliable indices of device efficacy. Preliminary analysis indicates that immediately after implantation, the device with medium porosity performs better than the devices with lower and higher porosities


  • Angiographic Assessment of the Performance of Flow Divertors to Treat Cerebral Aneurysms

    by Chander Sadasivan, Baruch B. Lieber, Liliana Cesar, Laszlo Miskolczi, Jaehoon Seong, Ajay K. Wakhloo

    Past clinical and experimental evidence suggests that cerebral aneurysms can be successfully excluded from the circulation solely by the endovascular placement of a flow diverting device across the aneurysm neck. These devices promote intraaneurysmal flow stasis and concomitant thrombosis by redirecting flow away from the aneurysm. To comprehensively test the efficacy of such flow divertors, we are implanting devices with three different porosities in a large cohort of elastase-induced aneurysms in rabbits. Treatment efficacy is quantified by a mathematical model that is fit to aneurysmal angiographic contrast washout curves. Results from three animals implanted with different device porosities are presented here. The model competently captures the behavior of the aneurysmal washout curves and provides reliable indices of device efficacy. Preliminary analysis indicates that immediately after implantation, the device with medium porosity performs better than the devices with lower and higher porosities

  • Correlation of Hemodynamic Events with Clinical and Pathological Observations

    by Baruch B. Lieber, Maria Siebes, Takami Yamaguchi

    The correlation of hemodynamic events with clinical or pathological observations is represented by a variety of applications reflecting the broad range of this theme. The position paper describes several cases in which benefits of combining imaging information with transport models of contrast material, can cause a gain in hemodynamic information. What appears to be lack of cohesiveness among the cases illustrates the variety in the application of hemodynamic research to the practice of medicine. Some of the contributions presented at the symposium do not directly apply to clinical medicine, but instead described mathematical models or applications to animal physiology or technical advancements in measuring blood rheology. Although related to this theme topic they fall somewhat outside the main scope. The topics summarized below demonstrate four examples in which translation of the research to the clinical arena can be realized in a short period of time. Overall recommendations for priority objectives related to this topic are provided at the end of this position paper.