Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography
- 1 February 2005
- journal article
- review article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 21 (1) , 165-176
Abstract
With increasing clinical use of cardiac CT imaging it is important that all health care providers referring for or administering such examinations are familiar with the concepts and values of radiation dosimetry in CT as well as with the basic principles of radiation protection. There are important technical differences pertinent to radiation dose between the CT scanner types that are currently being used for imaging of the heart and coronary arteries. As a result of these differences, the radiation dose typically is higher when a cardiac examination is performed with multidetector-row CT (MDCT) than when it is performed with electron beam CT. Several techniques have been described to reduce radiation dose of MDCT imaging by varying the X-ray tube current during a CT examination. The volume computed tomographic dose index (CTDIvol), the dose length product (DLP), and the effective dose (E) are the most useful parameters to describe and compare radiation doses received from cardiac CT examinations. When comparing radiation doses between scanning protocols and scanner types, the degree of image noise must be considered. Diagnostic, rather than aesthetic, quality of images should be the most important factor guiding the development of scanning protocols for cardiac CT imaging. Cardiac CT examinations should be ordered only by qualified health care providers, and the ordering clinicians should be aware of their responsibility of weighing risks of the radiation exposure against the expected benefits.Keywords
This publication has 24 references indexed in Scilit:
- Posterior mitral valve leaflet prolapse diagnosed with multislice spiral computed tomographyHeart, 2005
- Imaging of Congenital Coronary Anomalies With Multislice Computed TomographyMayo Clinic Proceedings, 2004
- Estimation of Radiation Exposure in 16-Detector Row Computed Tomography of the Heart with Retrospective ECG-gatingRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Patient Dose in Cardiac Computed TomographyHerz, 2003
- Radiation Exposure during Cardiac CT: Effective Doses at Multi–Detector Row CT and Electron-Beam CTRadiology, 2003
- Current Results and New Developments of Coronary Angiography With Use of Contrast-Enhanced Computed Tomography of the HeartMayo Clinic Proceedings, 2002
- Calculation of effective doseMedical Physics, 2000
- Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadaversEuropean Radiology, 1999
- Quantities used in radiological protectionAnnals of the ICRP, 1991
- Thermoluminescent Radiation Dosimetry Utilizing LiFHealth Physics, 1964