RKRonald S. Kuzo

Ronald S. Kuzo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ronald S. Kuzo has a total of 157 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The use of artificial intelligence to improve detection of acute incidental pulmonary emboli

    by Ronald S. Kuzo, David L. Levin, Alexander K. Bratt, Lara A. Walkoff, Garima Suman, Damon E. Houghton


  • Observer Performance for Detection of Pulmonary Nodules at Chest CT over a Large Range of Radiation Dose Levels

    by Joel G. Fletcher, David L. Levin, Anne-Marie G. Sykes, Rebecca M. Lindell, Darin B. White, Ronald S. Kuzo, Vighnesh Suresh, Lifeng Yu, Shuai Leng, David R. Holmes, et al.

    For depicting indeterminate pulmonary nodules size 5 mm or greater, radiation dose levels for chest CT can be reduced to one-third of the radiation dose level used in the National Lung Cancer Scree... Background There is a wide variation in radiation dose levels that can be used with chest CT in order to detect indeterminate pulmonary nodules. Purpose To compare the performance of lower-radiatio...


  • Open Access

    Evaluation of a projection-domain lung nodule insertion technique in thoracic CT

    by Chi Ma, Baiyu Chen, Chi Wan Koo, Edwin A Takahashi, Joel G Fletcher, Cynthia H McCollough, David L Levin, Ronald S Kuzo, Lyndsay D Viers, Stephanie A Vincent Sheldon, et al.

    Task-based assessment of computed tomography (CT) image quality requires a large number of cases with ground truth. Inserting lesions into existing cases to simulate positive cases is a promising alternative approach. The aim of this study was to evaluate a recently-developed raw-data based lesion insertion technique in thoracic CT. Lung lesions were segmented from patient CT images, forward projected, and reinserted into the same patient CT projection data. In total, 32 nodules of various attenuations were segmented from 21 CT cases. Two experienced radiologists and 2 residents blinded to the process independently evaluated these inserted nodules in two sub-studies. First, the 32 inserted and the 32 original nodules were presented in a randomized order and each received a rating score from 1 to 10 (1=absolutely artificial to 10=absolutely realistic). Second, the inserted and the corresponding original lesions were presented side-by-side to each reader, who identified the inserted lesion and provided a confidence score (1=no confidence to 5=completely certain). For the randomized evaluation, discrimination of real versus artificial nodules was poor with areas under the receiver operative characteristic curves being 0.69 (95% CI: 0.58-0.78), 0.57 (95% CI: 0.46-0.68), and 0.62 (95% CI: 0.54-0.69) for the 2 radiologists, 2 residents, and all 4 readers, respectively. For the side-by-side evaluation, although all 4 readers correctly identified inserted lesions in 103/128 pairs, the confidence score was moderate (2.6). Our projection-domain based lung nodule insertion technique provides a robust method to artificially generate clinical cases that prove to be difficult to differentiate from real cases.


  • Measurement of Caval Blood Flow with MRI During Respiratory Maneuvers: Implications for Vascular Contrast Opacification on Pulmonary CT Angiographic Studies

    by Ronald S. Kuzo, Robert A. Pooley, Julia E. Crook, Michael G. Heckman, Thomas C. Gerber

    OBJECTIVE. Transient interruption of the contrast bolus has been described as a physiologic artifact that can sometimes result in poor opacification of the pulmonary arteries on pulmonary CT angiographic studies. To better understand the mechanism underlying this artifact, we used velocity-encoded cine MRI to measure flow in the inferior vena cava (IVC) and superior vena cava (SVC) during respiratory maneuvers.SUBJECTS AND METHODS. Quantitative measurements of SVC and IVC flow per R-R interval were performed on 10 healthy volunteers (six men, four women; median age, 30 years; range, 25-55 years) with a retrospectively ECG-gated velocity-encoded gradient-echo cine sequence on a 1.5-T MRI unit with axial slices at the level of the diaphragm and just below the azygous vein confluence during free breathing, continuous inspiration, breath-hold at end inspiration, Valsalva maneuver, and breath-hold at end expiration.RESULTS. Median flow during free breathing was 38.9 mL in the SVC and 74.3 mL in the IVC, during...


    • 1 January 2007
      • Vol. 34, 5-9

    Coronary computed tomographic angiography: current and future uses

    by Birgit Kantor, Ronald S. Kuzo, Thomas C. Gerber

    Coronary computed tomographic angiography (CCTA) is a direct but minimally invasive method of visualizing coronary arteries. Acceptable indications for this technique include the assessment of suspected or known coronary artery anomalies, the evaluation of chest pain syndromes in patients with non diagnostic stress tests or who are unable to exercise, and exclusion of an ischemic etiology in patients with unexplained left ventricular dysfunction. Assessment of coronary stents with a diameter of <3.0 mm and imaging of asymptomatic patients with a goal of establishing prognosis are currently not accepted indications for CCTA.


  • Computed Tomographic Angiography of the Coronary Arteries: Techniques and Applications

    by Thomas C. Gerber, Jerome F. Breen, Ronald S. Kuzo, Birgit Kantor, Eric E. Williamson, Robert E. Safford, Richard L. Morin


  • Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography

    by Martin Heuschmid, Julia K. Rothfuss, Stephen Schroeder, Michael Fenchel, Norbert Stauder, Christof Burgstahler, Andreas Franow, Ronald S. Kuzo, Axel Kuettner, Stephan Miller, et al.

    To assess functional parameters using multidetector-row computed tomography (MDCT) and echocardiography and to compare the results with magnetic resonance imaging (MRI).


  • Effect of Acquisition Technique on Radiation Dose and Image Quality in Multidetector Row Computed Tomography Coronary Angiography With Submillimeter Collimation

    by Thomas C. Gerber, Brian P. Stratmann, Ronald S. Kuzo, Birgit Kantor, Richard L. Morin

    We sought to examine effects of tube voltage and current on radiation dose and image quality for minimally invasive coronary angiography with a 16-slice multidetector row computed tomography (MDCT) scanner. We scanned the phantom used in the American College of Radiology Computed Tomography Accreditation Program at tube voltages of 80 and 120 kVp at 550, 650, and 750 mAseff, with and without a reduction in radiation dose by electrocardiographically (ECG) controlled tube current modulation (ECG pulsing). Without ECG pulsing, the effective dose was 3 to 13 mSv. On average, a 50% increase in tube voltage led to increased radiation dose (215%), contrast-to-noise ratio (150%), and decreased image noise (−48%). On average, a 17% increase in mAseff led to increased radiation dose (17%) and contrast-to-noise ratio (4%) and decreased image noise (−9%). Dose reduction by ECG pulsing (simulated heart rate, 70 beats per minute) was 28%. With ECG pulsing, noise in images reconstructed during ventricular systole was double that in images reconstructed during ventricular diastole. These quantitative findings about the relationships among scan acquisition parameters, radiation dose, and image quality have practical implications for using ECG pulsing to reduce radiation doses in MDCT coronary angiography.


  • ECG-Gated 16-MDCT of the Coronary Arteries: Assessment of Image Quality and Accuracy in Detecting Stenoses

    by Martin Heuschmid, Axel Kuettner, Stephen Schroeder, Tobias Trabold, Anja Feyer, Marcus D. Seemann, Ronald Kuzo, Claus D. Claussen, Andreas F. Kopp

    OBJECTIVE. The aim of this study was to investigate image quality and diagnostic accuracy in detecting coronary artery lesions using a 16-MDCT scanner.MATERIALS AND METHODS. Thirty-seven patients (28 men, nine women) underwent unenhanced helical CT and MDCT angiography of the coronary arteries. After patients received oral β-blocker medication, CT scans were obtained during a single breath-hold with a 16-MDCT scanner using ECG-gating (0.75-mm collimation, 2.8-mm table feed/rotation, 0.42-sec rotation time). The image quality was assessed in terms of artifacts and segment visibility by two reviewers. Stenosis severity was compared with the results of conventional invasive coronary angiography.RESULTS. The data evaluation of the image quality was based on a total of 488 segments, of which 380 segments were considered to have diagnostic image quality. One hundred eight segments (22.1%) could not be sufficiently evaluated because of severe calcifications (35 segments) and motion artifacts (73 segments). The m...


  • Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography

    by Thomas C. Gerber, Ronald S. Kuzo, Richard L. Morin

    With increasing clinical use of cardiac CT imaging it is important that all health care providers referring for or administering such examinations are familiar with the concepts and values of radiation dosimetry in CT as well as with the basic principles of radiation protection. There are important technical differences pertinent to radiation dose between the CT scanner types that are currently being used for imaging of the heart and coronary arteries. As a result of these differences, the radiation dose typically is higher when a cardiac examination is performed with multidetector-row CT (MDCT) than when it is performed with electron beam CT. Several techniques have been described to reduce radiation dose of MDCT imaging by varying the X-ray tube current during a CT examination. The volume computed tomographic dose index (CTDIvol), the dose length product (DLP), and the effective dose (E) are the most useful parameters to describe and compare radiation doses received from cardiac CT examinations. When comparing radiation doses between scanning protocols and scanner types, the degree of image noise must be considered. Diagnostic, rather than aesthetic, quality of images should be the most important factor guiding the development of scanning protocols for cardiac CT imaging. Cardiac CT examinations should be ordered only by qualified health care providers, and the ordering clinicians should be aware of their responsibility of weighing risks of the radiation exposure against the expected benefits.