Influence of insertion depth on stress distribution in orthodontic miniscrew and the surrounding bone by finite element analysis
Open Access
- 25 September 2021
- journal article
- research article
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 40 (5) , 1270-1276
Abstract
We aimed to elucidate stress distribution in miniscrews and the surrounding bone when miniscrews inserted at different depths were implanted vertically or obliquely. The distributions of the equivalent stress on the screw surface and the minimum principal stress in the surrounding bone were calculated using finite element models. When the miniscrews were inserted vertically and obliquely, screw head displacement, greatest equivalent stress on the miniscrew surface, and absolute value of minimum principal stresses in the surrounding bone decreased with increasing insertion depth. Stresses in the obliquely inserted miniscrew with upward traction were smaller than in other insertion conditions, irrespective of insertion depth. With the application of orthodontic force, stress distribution around the miniscrew and surrounding bone is closely related to the insertion depth and insertion angle, which mutually affect each other. In particular, the obliquely inserted miniscrew with upward traction might be the most secure against screw failure and fracture.Keywords
This publication has 25 references indexed in Scilit:
- Factors affecting stresses in cortical bone around miniscrew implantsThe Angle Orthodontist, 2012
- Fracture resistance of orthodontic mini-implants: a biomechanical in vitro studyEuropean Journal of Orthodontics, 2011
- Three-dimensional modeling and finite element analysis in treatment planning for orthodontic tooth movementAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2011
- Soft Tissue Thickness for Placement of an Orthodontic Miniscrew Using an Ultrasonic DeviceThe Angle Orthodontist, 2008
- Treatment of Class II Protrusion with Severe Crowding Using Indirect Miniscrew AnchorageThe Angle Orthodontist, 2007
- Clinical use of miniscrew implants as orthodontic anchorage: Success rates and postoperative discomfortAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2007
- Soft-tissue and cortical-bone thickness at orthodontic implant sitesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006
- Factors affecting the clinical success of screw implants used as orthodontic anchorageAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006
- Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorageAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2003
- The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem.Clinical Oral Implants Research, 1996