Keiichiro Watanabe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Keiichiro Watanabe has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Eiji Tanaka
Department of Orthodontics and Dentofacial Orthopedics, Tokushima University Graduate School of Biomedical Sciences, Tokushima, Japan
10 shared publications - Do-Gyoon Kim
Division of Orthodontics, The Ohio State University College of Dentistry, Columbus, OH 43210, USA
3 shared publications - Toru Deguchi
Division of Orthodontics, College of Dentistry, Ohio State University, Columbus, Ohio
3 shared publications Ai Ni
Division of Biostatistics, College of Public Health, The Ohio State University, Columbus, OH, USA
2 shared publicationsBeth S. Lee
Department of Physiology and Cell Biology, College of Medicine, The Ohio State University, Columbus, OH, USA
2 shared publicationsEmiko Nakaue
2 shared publications
Latest Publications
- Open Access
- 31 August 2026
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 51 (3)
Direct composite injection molding with bilayered three-dimensional-printed clear index: a fully digital workflow case report of post-orthodontic anterior tooth wear
This case report describes post-orthodontic direct composite restorations for anterior tooth wear using bilayered, three-dimensional (3D)-printed clear indices with a fully digital workflow. A patient with moderate incisal wear affecting the six maxillary anterior teeth underwent intraoral and facial scanning, followed by the creation of two digital wax-ups. Two sets of bilayered indices were fabricated, consisting of a rigid transparent outer shell for structural stability and a flexible inner liner for precise adaptation. Restoration was performed in two phases: alternate teeth were restored with the skipping-teeth first index, followed by restoration of the remaining teeth using the full-contour second index. The index design facilitated stable seating and controlled composite injection (Clearfil Majesty ES Flow Universal; Kuraray Noritake), which minimized material excess and simplified the finishing process while maintaining the planned morphology. The patient reported high satisfaction with comfort and treatment efficiency. At 15-month follow-up, all restorations remained intact with excellent marginal adaptation, surface quality, and esthetics. Within the limitations of this report, the use of bilayered 3D-printed clear indices suggests a feasible and conservative approach for managing anterior tooth wear.
- 31 August 2026
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 51 (3)
Open AccessDirect composite injection molding with bilayered three-dimensional-printed clear index: a fully digital workflow case report of post-orthodontic anterior tooth wear
This case report describes post-orthodontic direct composite restorations for anterior tooth wear using bilayered, three-dimensional (3D)-printed clear indices with a fully digital workflow. A patient with moderate incisal wear affecting the six maxillary anterior teeth underwent intraoral and facial scanning, followed by the creation of two digital wax-ups. Two sets of bilayered indices were fabricated, consisting of a rigid transparent outer shell for structural stability and a flexible inner liner for precise adaptation. Restoration was performed in two phases: alternate teeth were restored with the skipping-teeth first index, followed by restoration of the remaining teeth using the full-contour second index. The index design facilitated stable seating and controlled composite injection (Clearfil Majesty ES Flow Universal; Kuraray Noritake), which minimized material excess and simplified the finishing process while maintaining the planned morphology. The patient reported high satisfaction with comfort and treatment efficiency. At 15-month follow-up, all restorations remained intact with excellent marginal adaptation, surface quality, and esthetics. Within the limitations of this report, the use of bilayered 3D-printed clear indices suggests a feasible and conservative approach for managing anterior tooth wear.
- Open Access
- 27 September 2025
- Published by Elsevier in JADA Foundational Science
- Vol. 4
Presurgical orthodontic treatment with ultraearly application of premaxilla-guiding nasoalveolar molding in feeding neonates
- 27 September 2025
- Published by Elsevier in JADA Foundational Science
- Vol. 4
Open AccessPresurgical orthodontic treatment with ultraearly application of premaxilla-guiding nasoalveolar molding in feeding neonates
- 6 June 2025
- Published by Elsevier in AJO-DO Clinical Companion
- Vol. 5 (4) , 405-419
Anterior open bite treatment with mandibular counterclockwise rotation by miniscrew-anchored molar intrusion
- 6 June 2025
- Published by Elsevier in AJO-DO Clinical Companion
- Vol. 5 (4) , 405-419
Anterior open bite treatment with mandibular counterclockwise rotation by miniscrew-anchored molar intrusion
- Open Access
- 1 May 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 169, 107036
Multiscale characterization of jawbone treated with osteoporosis therapeutic agents
- 1 May 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 169, 107036
Open AccessMultiscale characterization of jawbone treated with osteoporosis therapeutic agents
- 21 October 2024
- Published by Elsevier in AJO-DO Clinical Companion
- Vol. 5 (1) , 82-92
Scissor bite correction with miniscrew-anchored uprighting: A case report
- 21 October 2024
- Published by Elsevier in AJO-DO Clinical Companion
- Vol. 5 (1) , 82-92
Scissor bite correction with miniscrew-anchored uprighting: A case report
- 14 February 2023
- Published by Elsevier in AJO-DO Clinical Companion
- Vol. 3 (2) , 149-162
A patient with unilateral posterior crossbite treated with modified unilateral surgically-assisted rapid maxillary expansion
- 14 February 2023
- Published by Elsevier in AJO-DO Clinical Companion
- Vol. 3 (2) , 149-162
A patient with unilateral posterior crossbite treated with modified unilateral surgically-assisted rapid maxillary expansion
- Open Access
- 20 July 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-11
Thread shape, cortical bone thickness, and magnitude and distribution of stress caused by the loading of orthodontic miniscrews: finite element analysis
Cortical bone thickness is assumed to be a major factor regulating miniscrew stability. We investigated stress distribution in two miniscrews with different thread shapes (type A and B) and in cortical bone of three different thicknesses using three-dimensional (3D) finite element (FE) models. More specifically, 3D FE models of two different miniscrews were created and placed obliquely or vertically into a cylindrical bone model representing different cortical bone thicknesses. When force was applied to the miniscrew, the stress distribution on the screw surface and in the peri-implant bone was assessed using FE methodology. Miniscrew safety was evaluated using a modified Soderberg safety factor. Screw head displacement increased with a decrease in cortical bone thickness, irrespective of screw type. The smallest minimum principal stresses on the screw surfaces remained constant in type A miniscrews on changes in cortical bone thickness. Minimum principal stresses also appeared on the cortical bone surface. Lower absolute values of minimum principal stresses were seen in type A miniscrews when placed vertically and with upward traction in obliquely placed type B miniscrews. Both miniscrews had acceptable safety factor values. Taken together, orthodontists should select and use the suitable miniscrew for each patient in consideration of bone properties.
- 20 July 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-11
Open AccessThread shape, cortical bone thickness, and magnitude and distribution of stress caused by the loading of orthodontic miniscrews: finite element analysis
Cortical bone thickness is assumed to be a major factor regulating miniscrew stability. We investigated stress distribution in two miniscrews with different thread shapes (type A and B) and in cortical bone of three different thicknesses using three-dimensional (3D) finite element (FE) models. More specifically, 3D FE models of two different miniscrews were created and placed obliquely or vertically into a cylindrical bone model representing different cortical bone thicknesses. When force was applied to the miniscrew, the stress distribution on the screw surface and in the peri-implant bone was assessed using FE methodology. Miniscrew safety was evaluated using a modified Soderberg safety factor. Screw head displacement increased with a decrease in cortical bone thickness, irrespective of screw type. The smallest minimum principal stresses on the screw surfaces remained constant in type A miniscrews on changes in cortical bone thickness. Minimum principal stresses also appeared on the cortical bone surface. Lower absolute values of minimum principal stresses were seen in type A miniscrews when placed vertically and with upward traction in obliquely placed type B miniscrews. Both miniscrews had acceptable safety factor values. Taken together, orthodontists should select and use the suitable miniscrew for each patient in consideration of bone properties.
- Open Access
- 9 June 2022
- Published by Elsevier in Journal of Dental Sciences
- Vol. 20 (2) , 1236-1241
Identification of key determinant for predicting feasible mandibular molars distalization
- 9 June 2022
- Published by Elsevier in Journal of Dental Sciences
- Vol. 20 (2) , 1236-1241
Open AccessIdentification of key determinant for predicting feasible mandibular molars distalization
- Open Access
- 11 December 2021
- Published by Elsevier in Journal of Dental Sciences
- Vol. 17 (3) , 1244-1252
Mechanical stability of orthodontic miniscrew depends on a thread shape
- 11 December 2021
- Published by Elsevier in Journal of Dental Sciences
- Vol. 17 (3) , 1244-1252
Open AccessMechanical stability of orthodontic miniscrew depends on a thread shape
- Open Access
- 25 September 2021
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 40 (5) , 1270-1276
Influence of insertion depth on stress distribution in orthodontic miniscrew and the surrounding bone by finite element analysis
We aimed to elucidate stress distribution in miniscrews and the surrounding bone when miniscrews inserted at different depths were implanted vertically or obliquely. The distributions of the equivalent stress on the screw surface and the minimum principal stress in the surrounding bone were calculated using finite element models. When the miniscrews were inserted vertically and obliquely, screw head displacement, greatest equivalent stress on the miniscrew surface, and absolute value of minimum principal stresses in the surrounding bone decreased with increasing insertion depth. Stresses in the obliquely inserted miniscrew with upward traction were smaller than in other insertion conditions, irrespective of insertion depth. With the application of orthodontic force, stress distribution around the miniscrew and surrounding bone is closely related to the insertion depth and insertion angle, which mutually affect each other. In particular, the obliquely inserted miniscrew with upward traction might be the most secure against screw failure and fracture.
- 25 September 2021
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 40 (5) , 1270-1276
Open AccessInfluence of insertion depth on stress distribution in orthodontic miniscrew and the surrounding bone by finite element analysis
We aimed to elucidate stress distribution in miniscrews and the surrounding bone when miniscrews inserted at different depths were implanted vertically or obliquely. The distributions of the equivalent stress on the screw surface and the minimum principal stress in the surrounding bone were calculated using finite element models. When the miniscrews were inserted vertically and obliquely, screw head displacement, greatest equivalent stress on the miniscrew surface, and absolute value of minimum principal stresses in the surrounding bone decreased with increasing insertion depth. Stresses in the obliquely inserted miniscrew with upward traction were smaller than in other insertion conditions, irrespective of insertion depth. With the application of orthodontic force, stress distribution around the miniscrew and surrounding bone is closely related to the insertion depth and insertion angle, which mutually affect each other. In particular, the obliquely inserted miniscrew with upward traction might be the most secure against screw failure and fracture.