Relationship among coronary plaque compliance, coronary risk factors and tissue characteristics evaluated by integrated backscatter intravascular ultrasound
Authors:
- Yoshiyuki IshiharaYIYoshiyuki Ishihara
- Masanori KawasakiMKMasanori Kawasaki
- Arihiro HattoriAHArihiro Hattori
- Hajime ImaiHIHajime Imai
- Shigekiyo TakahashiSTShigekiyo Takahashi
- Hironobu SatoHSHironobu Sato
- Tomoki KubotaTKTomoki Kubota
- Munenori OkuboMOMunenori Okubo
- Shinsuke OjioSOShinsuke Ojio
- Kazuhiko NishigakiKNKazuhiko Nishigaki
- Genzou TakemuraGTGenzou Takemura
- Hisayoshi FujiwaraHFHisayoshi Fujiwara
Open Access
- 30 July 2012
- journal article
- research article
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 10 (1) , 32
Abstract
Background: The purpose of the present study was to evaluate the mechanical properties of coronary plaques and plaque behavior, and to elucidate the relationship among tissue characteristics of coronary plaques, mechanical properties and coronary risk factors using integrated backscatter intravascular ultrasound (IB-IVUS). Methods: Non-targeted plaques with moderate stenosis (plaque burden at the minimal lumen site: 50-70%) located proximal to the site of the percutaneous coronary intervention target lesions were evaluated by IB-IVUS. Thirty-six plaques (less calcified group: an arc of calcification ≤10°) in 36 patients and 22 plaques (moderately calcified group: 10° < an arc of calcification ≤60°) in 22 patients were evaluated. External elastic membrane volume (EEMV) compliance, lumen volume (LV) compliance, plaque volume (PV) response (difference between PV in systole and diastole), EEM area stiffness index were measured at the minimal lumen site. Relative lipid volume (lipid volume/internal elastic membrane volume) was calculated by IB-IVUS. Results: In the less calcified group, there was a significant correlation between EEMV compliance and the relative lipid volume (r = 0.456, p = 0.005). There was a significant inverse correlation between EEM area stiffness index and the relative lipid volume (p = 0.032, r = −0.358). The LV compliance and EEM area stiffness index were significantly different in the diabetes mellitus (DM) group than in the non-DM group (1.32 ± 1.49 vs. 2.47 ± 1.79%/10 mmHg, p =0.014 and 28.3 ± 26.0 vs. 15.7 ± 17.2, p =0.020). The EEMV compliance and EEM area stiffness index were significantly different in the hypertension (HTN) group than in the non-HTN group (0.77 ± 0.68 vs. 1.57 ± 0.95%/10 mmHg, p =0.012 and 26.5 ± 24.3 vs. 13.0 ± 16.7, p =0.020). These relationships were not seen in the moderately calcified group. Conclusion: The present study provided new findings that there was a significant correlation between mechanical properties and tissue characteristics of coronary arteries. In addition, our results suggested that the EEMV compliance and the LV compliance were independent and the compliance was significantly impaired in the patients with DM and/or HTN. Assessment of coronary mechanical properties during PCI may provide us with useful information regarding the risk stratification of patients with coronary heart disease.Keywords
This publication has 28 references indexed in Scilit:
- Tissue Characterization of Coronary Plaques and Assessment of Thickness of Fibrous Cap Using Integrated Backscatter Intravascular Ultrasound - Comparison With Histology and Optical Coherence Tomography -Circulation Journal, 2010
- Tissue Characterization of Coronary Plaques Comparison of Integrated Backscatter Intravascular Ultrasound With Virtual Histology Intravascular UltrasoundCirculation Journal, 2008
- Volumetric Quantitative Analysis of Tissue Characteristics of Coronary Plaques After Statin Therapy Using Three-Dimensional Integrated Backscatter Intravascular UltrasoundJACC, 2005
- Assessment of arterial medial characteristics in human carotid arteries using integrated backscatter ultrasound and its histological implicationsAtherosclerosis, 2005
- Characterizing Vulnerable Plaque Features With Intravascular ElastographyCirculation, 2003
- In Vivo Quantitative Tissue Characterization of Human Coronary Arterial Plaques by Use of Integrated Backscatter Intravascular Ultrasound and Comparison With Angioscopic FindingsCirculation, 2002
- Dynamic expansion of the coronary arteries: Implications for intravascular ultrasound measurementsAmerican Heart Journal, 1995
- Determinants of coronary compliance in patients with coronary artery disease: An intravascular ultrasound studyJACC, 1994
- Measurement by intracoronary ultrasound of in vivo arterial distensibility within atherosclerotic lesionsThe American Journal of Cardiology, 1993
- Stiffness and elastic behavior of human intracranial and extracranial arteriesJournal of Biomechanics, 1980