Hisayoshi Fujiwara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hisayoshi Fujiwara has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Arihiro Hattori
Department of Cardiology, Gifu University Graduate School of Medicine, 1-1 Yanagido, Gifu, 501-1194, Japan
2 shared publications - Genzou Takemura
Department of Cardiology, Gifu University Graduate School of Medicine, Gifu, Japan
2 shared publications - Kazuhiko Nishigaki
Department of Cardiology, Gifu University Graduate School of Medicine, Gifu, Japan
2 shared publications - Masanori Kawasaki
Department of Cardiovascular Medicine, Gifu Heart Center, Gifu, Japan
2 shared publications - Shinya Minatoguchi
Affiliation Department of Cardiology, Gifu Municipal Hospital, Gifu, Japan
2 shared publications - Tomoki Kubota
Department of Cardiology, Gifu University Graduate School of Medicine, 1-1 Yanagido, Gifu, 501-1194, Japan
2 shared publications
Latest Publications
- Open Access
- 6 August 2012
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 10 (1) , 33
Comparison between integrated backscatter intravascular ultrasound and 64-slice multi-detector row computed tomography for tissue characterization and volumetric assessment of coronary plaques
Background: The purpose of this study was to determine the cut-off values of Hounsfield units (HU) for the discrimination of plaque components and to evaluate the feasibility of measurement of the volume of plaque components using multi-detector row computed tomography (MDCT). Methods: Coronary lesions (125 lesions in 125 patients) were visualized by both integrated backscatter intravascular ultrasound (IB-IVUS) and 64-slice MDCT at the same site. The IB values were used as a gold standard to determine the cut off values of HU for the discrimination of plaque components. Results: Plaques were classified as lipid pool (n =50), fibrosis (n =65) or calcification (n =35) by IB-IVUS. The HU of lipid pool, fibrosis and calcification were 18 ± 18 HU (−19 to 58 HU), 95 ± 24 HU (46 to 154 HU) and 378 ± 99 HU (188 to 605 HU), respectively. Using receiver operating characteristic curve analysis, a threshold of 50 HU was the optimal cutoff values to discriminate lipid pool from fibrosis. Lipid volume measured by MDCT was correlated with that measured by IB-IVUS (r =0.66, p <0.001), whereas fibrous volume was not (r =0.21, p =0.059). Conclusion: Lipid volume measured by MDCT was moderately correlated with that measured by IB-IVUS. MDCT may be useful for volumetric assessment of the lipid volume of coronary plaques, whereas the assessment of fibrosis volume was unstable.
- 6 August 2012
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 10 (1) , 33
Open AccessComparison between integrated backscatter intravascular ultrasound and 64-slice multi-detector row computed tomography for tissue characterization and volumetric assessment of coronary plaques
Background: The purpose of this study was to determine the cut-off values of Hounsfield units (HU) for the discrimination of plaque components and to evaluate the feasibility of measurement of the volume of plaque components using multi-detector row computed tomography (MDCT). Methods: Coronary lesions (125 lesions in 125 patients) were visualized by both integrated backscatter intravascular ultrasound (IB-IVUS) and 64-slice MDCT at the same site. The IB values were used as a gold standard to determine the cut off values of HU for the discrimination of plaque components. Results: Plaques were classified as lipid pool (n =50), fibrosis (n =65) or calcification (n =35) by IB-IVUS. The HU of lipid pool, fibrosis and calcification were 18 ± 18 HU (−19 to 58 HU), 95 ± 24 HU (46 to 154 HU) and 378 ± 99 HU (188 to 605 HU), respectively. Using receiver operating characteristic curve analysis, a threshold of 50 HU was the optimal cutoff values to discriminate lipid pool from fibrosis. Lipid volume measured by MDCT was correlated with that measured by IB-IVUS (r =0.66, p <0.001), whereas fibrous volume was not (r =0.21, p =0.059). Conclusion: Lipid volume measured by MDCT was moderately correlated with that measured by IB-IVUS. MDCT may be useful for volumetric assessment of the lipid volume of coronary plaques, whereas the assessment of fibrosis volume was unstable.
- Open Access
- 30 July 2012
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 10 (1) , 32
Relationship among coronary plaque compliance, coronary risk factors and tissue characteristics evaluated by integrated backscatter intravascular ultrasound
Background: The purpose of the present study was to evaluate the mechanical properties of coronary plaques and plaque behavior, and to elucidate the relationship among tissue characteristics of coronary plaques, mechanical properties and coronary risk factors using integrated backscatter intravascular ultrasound (IB-IVUS). Methods: Non-targeted plaques with moderate stenosis (plaque burden at the minimal lumen site: 50-70%) located proximal to the site of the percutaneous coronary intervention target lesions were evaluated by IB-IVUS. Thirty-six plaques (less calcified group: an arc of calcification ≤10°) in 36 patients and 22 plaques (moderately calcified group: 10° < an arc of calcification ≤60°) in 22 patients were evaluated. External elastic membrane volume (EEMV) compliance, lumen volume (LV) compliance, plaque volume (PV) response (difference between PV in systole and diastole), EEM area stiffness index were measured at the minimal lumen site. Relative lipid volume (lipid volume/internal elastic membrane volume) was calculated by IB-IVUS. Results: In the less calcified group, there was a significant correlation between EEMV compliance and the relative lipid volume (r = 0.456, p = 0.005). There was a significant inverse correlation between EEM area stiffness index and the relative lipid volume (p = 0.032, r = −0.358). The LV compliance and EEM area stiffness index were significantly different in the diabetes mellitus (DM) group than in the non-DM group (1.32 ± 1.49 vs. 2.47 ± 1.79%/10 mmHg, p =0.014 and 28.3 ± 26.0 vs. 15.7 ± 17.2, p =0.020). The EEMV compliance and EEM area stiffness index were significantly different in the hypertension (HTN) group than in the non-HTN group (0.77 ± 0.68 vs. 1.57 ± 0.95%/10 mmHg, p =0.012 and 26.5 ± 24.3 vs. 13.0 ± 16.7, p =0.020). These relationships were not seen in the moderately calcified group. Conclusion: The present study provided new findings that there was a significant correlation between mechanical properties and tissue characteristics of coronary arteries. In addition, our results suggested that the EEMV compliance and the LV compliance were independent and the compliance was significantly impaired in the patients with DM and/or HTN. Assessment of coronary mechanical properties during PCI may provide us with useful information regarding the risk stratification of patients with coronary heart disease.
- 30 July 2012
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 10 (1) , 32
Open AccessRelationship among coronary plaque compliance, coronary risk factors and tissue characteristics evaluated by integrated backscatter intravascular ultrasound
Background: The purpose of the present study was to evaluate the mechanical properties of coronary plaques and plaque behavior, and to elucidate the relationship among tissue characteristics of coronary plaques, mechanical properties and coronary risk factors using integrated backscatter intravascular ultrasound (IB-IVUS). Methods: Non-targeted plaques with moderate stenosis (plaque burden at the minimal lumen site: 50-70%) located proximal to the site of the percutaneous coronary intervention target lesions were evaluated by IB-IVUS. Thirty-six plaques (less calcified group: an arc of calcification ≤10°) in 36 patients and 22 plaques (moderately calcified group: 10° < an arc of calcification ≤60°) in 22 patients were evaluated. External elastic membrane volume (EEMV) compliance, lumen volume (LV) compliance, plaque volume (PV) response (difference between PV in systole and diastole), EEM area stiffness index were measured at the minimal lumen site. Relative lipid volume (lipid volume/internal elastic membrane volume) was calculated by IB-IVUS. Results: In the less calcified group, there was a significant correlation between EEMV compliance and the relative lipid volume (r = 0.456, p = 0.005). There was a significant inverse correlation between EEM area stiffness index and the relative lipid volume (p = 0.032, r = −0.358). The LV compliance and EEM area stiffness index were significantly different in the diabetes mellitus (DM) group than in the non-DM group (1.32 ± 1.49 vs. 2.47 ± 1.79%/10 mmHg, p =0.014 and 28.3 ± 26.0 vs. 15.7 ± 17.2, p =0.020). The EEMV compliance and EEM area stiffness index were significantly different in the hypertension (HTN) group than in the non-HTN group (0.77 ± 0.68 vs. 1.57 ± 0.95%/10 mmHg, p =0.012 and 26.5 ± 24.3 vs. 13.0 ± 16.7, p =0.020). These relationships were not seen in the moderately calcified group. Conclusion: The present study provided new findings that there was a significant correlation between mechanical properties and tissue characteristics of coronary arteries. In addition, our results suggested that the EEMV compliance and the LV compliance were independent and the compliance was significantly impaired in the patients with DM and/or HTN. Assessment of coronary mechanical properties during PCI may provide us with useful information regarding the risk stratification of patients with coronary heart disease.