Wavelength-spatial multiplexed optical coherence tomography via parallel spatial encoding for high-speed, high-precision imaging
Authors:
- Jihui ZhengJZJihui Zheng
- Xinlu ZhaiXZXinlu Zhai
- Hongyi ChenHCHongyi Chen
- Mengyang ZhaoMZMengyang Zhao
- Haize HeHHHaize He
- Xiyu ZhuXZXiyu Zhu
- Longjun ZhengLZLongjun Zheng
- Zhengrui WuZWZhengrui Wu
- Wenxin ZhangWZWenxin Zhang
- Zuxing ZhangZuxing Zhang
Preprint
- 20 September 2026
- preprint
- Published by Elsevier in SSRN Electronic Journal
Abstract
Traditional swept-source optical coherence tomography (SS-OCT) typically rely on point-by-point scanning and complex signal synchronization mechanisms, while their imaging depth and measurement range are fundamentally constrained by the limited resampling rate of k-clock signals. To address this, we propose wavelength-spatial multiplexed OCT with parallel spatial encoding for high-speed and high-precision imaging. A diffraction grating is employed to convert conventional point-scanning measurement into line-scanning measurement by establishing a wavelength-to-space mapping, allowing the line spatial information of the target to be encoded in parallel within a single interference sweep. To recover the encoded line spatial information, an equal-frequency subdivision resampling (EFSR) method is proposed to resample the interference signal on a refined grid, thereby compensating for errors caused by the nonlinear sweep of the light source. The resampled signal is then processed using short-time Fourier transform (STFT) analysis to reconstruct depth-resolved profiles along the encoded line. Experimental results demonstrate a lateral measurement error below 0.90 μm. For axial measurements, the standard deviation across 100 repeated measurements is 117.6 nm. The system also clearly resolves multilayer interfaces in tomographic images. The proposed approach combines parallel spatial encoding with k-clock-based resampling to enable high-precision three-dimensional imaging.Keywords
This publication has 18 references indexed in Scilit:
- Rapid Multipoint Gas Sensing Using a Silicon-Photonic-Integrated Widely-Tunable Narrow-Linewidth Laser by FMCW InterferometryJournal of Lightwave Technology, 2026
- High-precision 3D imaging using spectral encoding based on the mode-locked optical frequency combApplied Optics, 2024
- High-speed, long-range and wide-field OCT for in vivo 3D imaging of the oral cavity achieved by a 600 kHz swept source laserBiomedical Optics Express, 2024
- Converting non-confocal measurements into semi-confocal ones with timing-accuracy improving for non-line-of-sight imagingOptics and Lasers in Engineering, 2024
- Clinical applications of anterior segment swept-source optical coherence tomography: A systematic reviewPhotodiagnosis and Photodynamic Therapy, 2023
- Surgical microscope integrated MHz SS-OCT with live volumetric visualizationBiomedical Optics Express, 2023
- High-Precision Silicon-Integrated Frequency-Modulated Continuous Wave LiDAR Calibrated Using a MicroresonatorACS Photonics, 2022
- Video-rate high-precision time-frequency multiplexed 3D coherent rangingNature Communications, 2022
- Retinal applications of swept source optical coherence tomography (OCT) and optical coherence tomography angiography (OCTA)Progress in Retinal and Eye Research, 2021
- Simple and robust calibration procedure for k-linearization and dispersion compensation in optical coherence tomographyJournal of Biomedical Optics, 2019