Wenxin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wenxin Zhang has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
Ping Xue
State Key Laboratory of Low‐Dimensional Quantum Physics and Department of Physics Tsinghua University Beijing China
7 shared publicationsNing Liu
College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technology) Nanjing University of Posts and Telecommunications Nanjing China
5 shared publications- Xiao Zhang
School of Medical Technology, Beijing Institute of Technology, Beijing, China
5 shared publications Bin He
State Key Laboratory of Low‐Dimensional Quantum Physics and Department of Physics Tsinghua University Beijing China
4 shared publicationsFu Zhu
College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technology) Nanjing University of Posts and Telecommunications Nanjing China
4 shared publicationsYangkang Wu
College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technology) Nanjing 210023, China
4 shared publications
Latest Publications
- Open Access
- 20 September 2026
- Published by Elsevier in SSRN Electronic Journal
Wavelength-spatial multiplexed optical coherence tomography via parallel spatial encoding for high-speed, high-precision imaging
Traditional swept-source optical coherence tomography (SS-OCT) typically rely on point-by-point scanning and complex signal synchronization mechanisms, while their imaging depth and measurement range are fundamentally constrained by the limited resampling rate of k-clock signals. To address this, we propose wavelength-spatial multiplexed OCT with parallel spatial encoding for high-speed and high-precision imaging. A diffraction grating is employed to convert conventional point-scanning measurement into line-scanning measurement by establishing a wavelength-to-space mapping, allowing the line spatial information of the target to be encoded in parallel within a single interference sweep. To recover the encoded line spatial information, an equal-frequency subdivision resampling (EFSR) method is proposed to resample the interference signal on a refined grid, thereby compensating for errors caused by the nonlinear sweep of the light source. The resampled signal is then processed using short-time Fourier transform (STFT) analysis to reconstruct depth-resolved profiles along the encoded line. Experimental results demonstrate a lateral measurement error below 0.90 μm. For axial measurements, the standard deviation across 100 repeated measurements is 117.6 nm. The system also clearly resolves multilayer interfaces in tomographic images. The proposed approach combines parallel spatial encoding with k-clock-based resampling to enable high-precision three-dimensional imaging.
- 20 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessWavelength-spatial multiplexed optical coherence tomography via parallel spatial encoding for high-speed, high-precision imaging
Traditional swept-source optical coherence tomography (SS-OCT) typically rely on point-by-point scanning and complex signal synchronization mechanisms, while their imaging depth and measurement range are fundamentally constrained by the limited resampling rate of k-clock signals. To address this, we propose wavelength-spatial multiplexed OCT with parallel spatial encoding for high-speed and high-precision imaging. A diffraction grating is employed to convert conventional point-scanning measurement into line-scanning measurement by establishing a wavelength-to-space mapping, allowing the line spatial information of the target to be encoded in parallel within a single interference sweep. To recover the encoded line spatial information, an equal-frequency subdivision resampling (EFSR) method is proposed to resample the interference signal on a refined grid, thereby compensating for errors caused by the nonlinear sweep of the light source. The resampled signal is then processed using short-time Fourier transform (STFT) analysis to reconstruct depth-resolved profiles along the encoded line. Experimental results demonstrate a lateral measurement error below 0.90 μm. For axial measurements, the standard deviation across 100 repeated measurements is 117.6 nm. The system also clearly resolves multilayer interfaces in tomographic images. The proposed approach combines parallel spatial encoding with k-clock-based resampling to enable high-precision three-dimensional imaging.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 32 (4: Adv. Bi) , 1-9
Targeted ROI Scanning Strategy for OCTA with Uniform Spatial-Temporal Sampling
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 32 (4: Adv. Bi) , 1-9
Targeted ROI Scanning Strategy for OCTA with Uniform Spatial-Temporal Sampling
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 32 (4: Adv. Bi) , 1-8
A Compact Linear-in-Wavenumber Spectrometer With a 1800 Lines/mm Grating for 4.8 mm Imaging Depth in SD-OCT
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 32 (4: Adv. Bi) , 1-8
A Compact Linear-in-Wavenumber Spectrometer With a 1800 Lines/mm Grating for 4.8 mm Imaging Depth in SD-OCT
- Open Access
- 15 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 144975-144981
Computationally Efficient Artifact Suppression for Optical Coherence Tomography Angiography
In optical coherence tomography angiography (OCTA), vessels exhibit tail artifacts beneath them in B-scan images. These superficial vessel tails cast shadows on deeper vascular layers, significantly degrading image quality. Current artifact suppression methods often require complex algorithms and extensive computation, limiting their practicality. To address this, we propose a computationally efficient image processing technique that simultaneously reduces artifacts to advance clinical OCTA applications. Our method integrates OCT structural images and OCTA images, and selectively enhances the blood-vessel wall interface, using vessel wall signals as markers for vascular positioning, achieving shorter tail artifacts with minimal processing overhead. Experiment results demonstrate that our approach requires only one-tenth of the computation time of traditional cmOCTA techniques, showing more significant speed improvements compared to other artifact suppression methods. Moreover, our method achieves effective artifact suppression comparable to conventional artifact removal methods at this high speed. Experimental validation using palm vasculature demonstrates the potential of our approach for real-time imaging and suggests that it may support clinical scenarios requiring timely feedback.
- 15 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 144975-144981
Open AccessComputationally Efficient Artifact Suppression for Optical Coherence Tomography Angiography
In optical coherence tomography angiography (OCTA), vessels exhibit tail artifacts beneath them in B-scan images. These superficial vessel tails cast shadows on deeper vascular layers, significantly degrading image quality. Current artifact suppression methods often require complex algorithms and extensive computation, limiting their practicality. To address this, we propose a computationally efficient image processing technique that simultaneously reduces artifacts to advance clinical OCTA applications. Our method integrates OCT structural images and OCTA images, and selectively enhances the blood-vessel wall interface, using vessel wall signals as markers for vascular positioning, achieving shorter tail artifacts with minimal processing overhead. Experiment results demonstrate that our approach requires only one-tenth of the computation time of traditional cmOCTA techniques, showing more significant speed improvements compared to other artifact suppression methods. Moreover, our method achieves effective artifact suppression comparable to conventional artifact removal methods at this high speed. Experimental validation using palm vasculature demonstrates the potential of our approach for real-time imaging and suggests that it may support clinical scenarios requiring timely feedback.
- 4 October 2023
- Published by Wiley in Journal of Biophotonics
- Vol. 17 (1) , e202300259
Size correction and deep image optimization in optical coherence tomography angiography with structural image‐assisted common parts extraction method
Tail artifact elimination is essential in optical coherence tomography angiography (OCTA) for the artifacts will prevent the reconstruction of the 3D vessel image. The tail artifacts of superficial vessels obscure the deep vascular signals and cause the signals at different depths to mix with each other. Most tail artifact elimination methods can shorten the tails but have difficulty in determining the lower boundary of the vessels. In this letter, we introduce a technique to extract vascular signals with more accurate vascular boundaries. With the help of structural image, our method can reconstruct the 3D image of the vascular network more precisely and perform better in deep areas. The images of vessels of palm are used to compare our new technique with previous common parts extraction method experimentally. The results show that our method removes the tail artifacts more thoroughly and has a significant advantage in imaging deep vessels.
- 4 October 2023
- Published by Wiley in Journal of Biophotonics
- Vol. 17 (1) , e202300259
Size correction and deep image optimization in optical coherence tomography angiography with structural image‐assisted common parts extraction method
Tail artifact elimination is essential in optical coherence tomography angiography (OCTA) for the artifacts will prevent the reconstruction of the 3D vessel image. The tail artifacts of superficial vessels obscure the deep vascular signals and cause the signals at different depths to mix with each other. Most tail artifact elimination methods can shorten the tails but have difficulty in determining the lower boundary of the vessels. In this letter, we introduce a technique to extract vascular signals with more accurate vascular boundaries. With the help of structural image, our method can reconstruct the 3D image of the vascular network more precisely and perform better in deep areas. The images of vessels of palm are used to compare our new technique with previous common parts extraction method experimentally. The results show that our method removes the tail artifacts more thoroughly and has a significant advantage in imaging deep vessels.
- 25 April 2023
- Published by Wiley in Journal of Biophotonics
- Vol. 16 (5)
Front Cover
OCTA can provide in‐vivo 3D microvasculature of bio‐tissue but faces challenges with motion sensitivity and time constraints. Our adaptive, efficient scanning protocol and motion compensation algorithms address these issues. Employing a high‐resolution spectral‐domain OCT system, our innovative OCTA method enhances vascular imaging performance and reconstructs human skin's relative blood speed imaging.Further details can be found in the article by Bin He, Yuxin Zhang, Zhe Meng, Zhijun He, Chengming Wang, Zhenyu Chen, Zichen Yin, Zhangwei Hu, Yejiong Shi, Ning Zhang, Wenxin Zhang, Guihuai Wang, and Ping Xue (e202200340) image
- 25 April 2023
- Published by Wiley in Journal of Biophotonics
- Vol. 16 (5)
Front Cover
OCTA can provide in‐vivo 3D microvasculature of bio‐tissue but faces challenges with motion sensitivity and time constraints. Our adaptive, efficient scanning protocol and motion compensation algorithms address these issues. Employing a high‐resolution spectral‐domain OCT system, our innovative OCTA method enhances vascular imaging performance and reconstructs human skin's relative blood speed imaging.Further details can be found in the article by Bin He, Yuxin Zhang, Zhe Meng, Zhijun He, Chengming Wang, Zhenyu Chen, Zichen Yin, Zhangwei Hu, Yejiong Shi, Ning Zhang, Wenxin Zhang, Guihuai Wang, and Ping Xue (e202200340) image
- 14 January 2023
- Published by Wiley in Journal of Biophotonics
- Vol. 16 (5) , e202200340
Optical coherence tomography angiography with adaptive multi‐time interval
Optical coherence tomography angiography (OCTA) can provide in vivo three‐dimensional microvasculature information of bio‐tissues, but it is sensitive to motion and time‐consuming. To overcome these limitations, we propose an adaptive multiple time interval correlation mapping OCTA with a time‐efficient scanning protocol and motion compensation algorithms. A spectral‐domain OCT with a center wavelength of 850 nm, A‐scan rate of 120 kHz and spatial resolution of 4.1 μm (axial) × 6.9 μm (lateral) is built to reconstruct the microvascular networks in the human arm. By adaptive optimization of the weights of different time interval B‐scan angiograms, our novel OCTA technique achieves better performance with a visible vascular density increase of ~67% and a signal‐to‐noise ratio enhancement of ~11.6%.
- 14 January 2023
- Published by Wiley in Journal of Biophotonics
- Vol. 16 (5) , e202200340
Optical coherence tomography angiography with adaptive multi‐time interval
Optical coherence tomography angiography (OCTA) can provide in vivo three‐dimensional microvasculature information of bio‐tissues, but it is sensitive to motion and time‐consuming. To overcome these limitations, we propose an adaptive multiple time interval correlation mapping OCTA with a time‐efficient scanning protocol and motion compensation algorithms. A spectral‐domain OCT with a center wavelength of 850 nm, A‐scan rate of 120 kHz and spatial resolution of 4.1 μm (axial) × 6.9 μm (lateral) is built to reconstruct the microvascular networks in the human arm. By adaptive optimization of the weights of different time interval B‐scan angiograms, our novel OCTA technique achieves better performance with a visible vascular density increase of ~67% and a signal‐to‐noise ratio enhancement of ~11.6%.
- 1 January 2023
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 21 (1) , 011102
Vibration measurement with frequency modulation single-pixel imaging
Single-pixel imaging can reconstruct the image of the object when the light traveling from the object to the detector is scattered or distorted. Most single-pixel imaging methods only obtain distribution of transmittance or reflectivity of the object. Some methods can obtain extra information, such as color and polarization information. However, there is no method that can get the vibration information when the object is vibrating during the measurement. Vibration information is very important, because unexpected vibration often means the occurrence of abnormal conditions. In this Letter, we introduce a method to obtain vibration information with the frequency modulation single-pixel imaging method. This method uses a light source with a special pattern to illuminate the object and analyzes the frequency of the total light intensity signal transmitted or reflected by the object. Compared to other single-pixel imaging methods, frequency modulation single-pixel imaging can obtain vibration information and maintain high signal-to-noise ratio and has potential on finding out hidden facilities under construction or instruments in work.
- 1 January 2023
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 21 (1) , 011102
Vibration measurement with frequency modulation single-pixel imaging
Single-pixel imaging can reconstruct the image of the object when the light traveling from the object to the detector is scattered or distorted. Most single-pixel imaging methods only obtain distribution of transmittance or reflectivity of the object. Some methods can obtain extra information, such as color and polarization information. However, there is no method that can get the vibration information when the object is vibrating during the measurement. Vibration information is very important, because unexpected vibration often means the occurrence of abnormal conditions. In this Letter, we introduce a method to obtain vibration information with the frequency modulation single-pixel imaging method. This method uses a light source with a special pattern to illuminate the object and analyzes the frequency of the total light intensity signal transmitted or reflected by the object. Compared to other single-pixel imaging methods, frequency modulation single-pixel imaging can obtain vibration information and maintain high signal-to-noise ratio and has potential on finding out hidden facilities under construction or instruments in work.
- 3 November 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (11)
Inside Cover
Optical coherence tomography angiography (OCTA) can visualize the blood vessels. However, tail artifacts of blood vessels make it difficult to reconstruct the 3‐D image of the vessels. A method is here proposed to remove tail artifacts in OCTA image and reconstruct the 3‐D blood vessel imaging by extracting the common parts of adjacent B‐Scan OCTA images. A clean 3‐D blood vessel image of palm is obtained.Further details can be found in the article by Wenxin Zhang, Bin He, Yangkang Wu, Yuxiu Tao, Fu Zhu, Wenchao Cai, Ning Liu, Qiang Zhao, and Ping Xue (e202200155). image
- 3 November 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (11)
Inside Cover
Optical coherence tomography angiography (OCTA) can visualize the blood vessels. However, tail artifacts of blood vessels make it difficult to reconstruct the 3‐D image of the vessels. A method is here proposed to remove tail artifacts in OCTA image and reconstruct the 3‐D blood vessel imaging by extracting the common parts of adjacent B‐Scan OCTA images. A clean 3‐D blood vessel image of palm is obtained.Further details can be found in the article by Wenxin Zhang, Bin He, Yangkang Wu, Yuxiu Tao, Fu Zhu, Wenchao Cai, Ning Liu, Qiang Zhao, and Ping Xue (e202200155). image
- 18 August 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (11) , e202200155
Tail artifacts removal of three‐dimensional optical coherence tomography angiography with common parts extraction method
In optical coherence tomography angiography (OCTA), each blood vessel has a tail artifact. These tails of superficial vessels will shadow underlying the deep vascular images and make it difficult to reconstruct the three‐dimensional (3D) image of the vessels. As 3D structure can provide much more information than two‐dimensional (2D) images, it is important to develop a method to remove the artifacts. In this letter, we introduce an image processing technique based on common parts extraction to remove the artifacts. With the help of subtraction operation and erode operation, our method can reconstruct the 3D image of vascular network by extracting the common parts of adjacent B‐Scan OCTA images. Vessels of palm are used as samples to experimentally demonstrate our technique. In the 3D image, we can see the interesting phenomenon that the ends of the blood vessels which close to the surface of the skin point toward the surface.
- 18 August 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (11) , e202200155
Tail artifacts removal of three‐dimensional optical coherence tomography angiography with common parts extraction method
In optical coherence tomography angiography (OCTA), each blood vessel has a tail artifact. These tails of superficial vessels will shadow underlying the deep vascular images and make it difficult to reconstruct the three‐dimensional (3D) image of the vessels. As 3D structure can provide much more information than two‐dimensional (2D) images, it is important to develop a method to remove the artifacts. In this letter, we introduce an image processing technique based on common parts extraction to remove the artifacts. With the help of subtraction operation and erode operation, our method can reconstruct the 3D image of vascular network by extracting the common parts of adjacent B‐Scan OCTA images. Vessels of palm are used as samples to experimentally demonstrate our technique. In the 3D image, we can see the interesting phenomenon that the ends of the blood vessels which close to the surface of the skin point toward the surface.