Determining ideal electrode insertion depth in paediatric cochlear implantation
- 19 July 2026
- journal article
- research article
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 283 (10) , 6413-6424
Abstract
Background Speech and language outcomes following early cochlear implantation vary widely among patients. Identifying modifiable, device-specific surgical parameters contributing to this variability is essential to optimise therapeutic outcomes. Objective This study investigates the association between electrode angular depth of insertion (aDOI) and speech perception outcomes in a homogeneous cohort of children implanted with a single lateral wall electrode design. Methods A cohort of 25 prelingually deaf children, aged 4 to 5 years at implantation, received unilateral Oticon Neuro ZTI cochlear implants at Mohammed VI University Hospital in Marrakech. All subjects had idiopathic deafness, completed at least two years of speech therapy, and demonstrated successful electrode activation. Postoperative modified Stenvers-view radiographs were used to calculate angular depth of insertion (aDOI). Auditory outcomes were assessed using APCEI and CAP scores. Response surface regression modelling was employed to explore the non-linear relationship between aDOI and auditory performance and to estimate the device-specific angular depth associated with peak predicted outcomes. Results The mean angular depth of insertion was 275°. APCEI scores ranged from 11 to 21, and CAP scores from 3 to 7. Non-linear modelling identified a predicted peak in auditory performance at approximately 340°, corresponding to an APCEI score of 17.67 and CAP score of 5.98. This value represents the model-derived optimum within the observed insertion range for the Oticon Neuro ZTI electrode platform. Conclusion Within this homogeneous cohort implanted with a single lateral wall electrode design, auditory outcomes demonstrated a non-linear association with angular depth of insertion, with peak predicted performance near 340°. These findings highlight the importance of device-specific insertion strategies and careful surgical planning. The results should not be generalized to other electrode designs without dedicated validation.Keywords
This publication has 29 references indexed in Scilit:
- A novel therapeutic pathway to the human cochlear nerveScientific Reports, 2024
- Impact of Cochlear Implant Electrode Array Design on Post‐Op Speech PerceptionOtolaryngology–Head and Neck Surgery, 2024
- Dependability of Electrode to Modiolus Distance in Patients Specific Electrode Selection: A Cadaveric Model StudyThe Laryngoscope, 2024
- Umfassender Literaturüberblick über die Anwendung der otologisch-chirurgischen Planungssoftware OTOPLAN® bei der CochleaimplantationHNO, 2024
- Comparison of depth of electrode insertion between cochleostomy and round window approach: a cadaveric studyEuropean Archives of Oto-Rhino-Laryngology, 2024
- Frequency‐to‐Place Mismatch Impacts Cochlear Implant Quality of Life, But Not Speech RecognitionThe Laryngoscope, 2024
- Auditory performance after cochlear reimplantationEuropean Annals of Otorhinolaryngology, Head and Neck Diseases, 2022
- Synchrotron Radiation-Based Reconstruction of the Human Spiral Ganglion: Implications for Cochlear ImplantationEar & Hearing, 2019
- Deeper insertion of electrode array result in better rehabilitation outcomes – Do we have evidence?International Journal of Pediatric Otorhinolaryngology, 2016
- Potential Benefits From Deeply Inserted Cochlear Implant ElectrodesEar & Hearing, 2011