Optimization of Transvenous Coil Position for Active Can Defibrillation Thresholds
Authors:
- Michael R. GoldMGMichael R. Gold
- Paul J. DegrootPDPaul J. Degroot
- Stephen R. ShorofskySSStephen R. Shorofsky
- 1 January 2000
- journal article
- clinical trial
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 11 (1) , 25-29
Abstract
Effect of SVC Position on DFT. Introduction: Lead systems that include an active pectoral pulse generator are now standard for initial defibrillator implantations. However, the optimal transvenous lead system and coil location for such active can configurations are unknown. The purpose of this study was to evaluate the benefit and optimal position of a superior vena cava (SVC) coil on defibrillation thresholds with an active left pectoral pulse generator and right ventricular coil. Methods and Results: This prospective, randomized study was performed on 27 patients. Each subject was evaluated with three lead configurations, with the order of testing randomized. Biphasic shocks were delivered between the right ventricular coil and an active can alone (unipolar), or an active can in common with the proximal coil positioned either at the right atrial/SVC junction (low SVC) or in the left subclavian vein (high SVC). Stored energies at defibrillation threshold were higher for the single‐coil, unipolar configuration (11.2 ± 6.6 J) than for the high (8.9 ± 4.2 J) or low (8.5 ± 4.2 J) SVC configurations (P < 0.01). Moreover, 96% of subjects had low (≤ 15 J) thresholds with the SVC coil in either position compared with 81% for the single‐coil configuration. Shock impedance (P ≤ 0.001) was increased with the unipolar configuration, whereas peak current was reduced (P < 0.001). Conclusion: The addition of a proximal transvenous coil to an active can unipolar lead configuration reduces defibrillation energy requirements. The position of this coil has no significant effect on defibrillation thresholds.Keywords
This publication has 29 references indexed in Scilit:
- Long‐Term Evaluation of the Ventricular Defibrillation Energy RequirementJournal of Cardiovascular Electrophysiology, 1998
- Transvenous Defibrillation Leads: Is There an Ideal Position of the Defibrillation Anode?Pacing and Clinical Electrophysiology, 1997
- A Multicenter, Randomized Trial Comparing an Active Can Implantable Defibrillator with a Passive Can SystemPacing and Clinical Electrophysiology, 1997
- Complications associated with pectoral cardioverter-defibrillator implantation: Comparison of subcutaneous and submuscular approachesJACC, 1996
- Effects of an active pectoral-pulse generator shell on defibrillation efficacy with a transvenous lead systemThe American Journal of Cardiology, 1996
- Transvenous Defibrillation Lead SystemsJournal of Cardiovascular Electrophysiology, 1996
- Optimal electrode position for transvenous defibrillation: A prospective randomized studyJACC, 1996
- Optimal electrode configuration for pectoral transvenous intplantable defibrillator without an active canThe American Journal of Cardiology, 1995
- Clinical predictors of the defibrillation threshold with the unipolar implantable defibrillation systemJACC, 1995
- Comparison of biphasic and monophasic shocks for defibrillation using a nonthoracotomy systemThe American Journal of Cardiology, 1993