Early Visual Performance and Subjective Experience After Bilateral Implantation of a Novel Fully Refractive Extended Depth of Focus Intraocular Lens
Authors:
- Richard McNeelyRMRichard McNeely
- Stephen StewartSSStephen Stewart
- Niraj MandalNMNiraj Mandal
- Jonathan MooreJMJonathan Moore
Open Access
- 1 May 2026
- journal article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-14
Abstract
To outline the early postoperative visual performance and subjective quality of vision (QoV) after implantation of a new fully refractive extended depth of focus intraocular lens (IOL). The study enrolled 103 patients undergoing bilateral phacoemulsification with implantation of the Tecnis PureSee IOL (Johnson & Johnson). Refraction, uncorrected (UDVA) and best-corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, defocus curves, electronic reading desk, QoV questionnaire and a halo and glare simulator were evaluated 3 months postoperatively. Mean binocular UDVA, UIVA and UNVA were −0.06 ± 0.07, 0.05 ± 0.08 and 0.20 ± 0.08 logMAR respectively. At 3 months, 83% were within ± 0.50D and 99% within ± 1.00D of the refractive aim. Minimal dysphotopsias and overall QoV scores of 8.68 ± 1.13 for the day and 8.08 ± 1.58 at night were reported. Of all patients, 98.1% reported better vision than preoperatively and 86.4% would recommend the procedure. Spectacle independence for distance, intermediate, and near was achieved in 100%, 94.2% and 66% of patients respectively. The Tecnis PureSee IOL provided excellent distance and intermediate vision with good functional near vision. Patients reported high postoperative QoV and subjective functional vision, with minimal visual side effects.Keywords
This publication has 31 references indexed in Scilit:
- A comparative evaluation of visual, refractive, and patient-reported outcomes of four premium intraocular lensesInternational Ophthalmology, 2025
- Evaluation of Clareon Vivity and PureSee intraocular lenses: optical quality, depth of focus and misalignment effectsScientific Reports, 2025
- Two novel extended depth-of-focus intraocular lenses targeted for mini-monovision: A prospective randomized controlled trialAmerican Journal of Ophthalmology, 2025
- Functional outcomes and quality of life after AcrySof IQ Vivity intraocular lens implantation in a real-world studyScientific Reports, 2024
- Tolerance to refractive error with a new extended depth of focus intraocular lensEye, 2024
- Quality of vision clinical outcomes for a new fully-refractive extended depth of focus Intraocular LensEye, 2024
- Optical and clinical simulated performance of a new refractive extended depth of focus intraocular lensEye, 2024
- Rate of Complete Spectacle Independence with a Trifocal Intraocular Lens: A Systematic Literature Review and Meta-AnalysisOphthalmology and Therapy, 2023
- Extended Depth of Focus Versus Trifocal for Intraocular Lens Implantation: An Updated Systematic Review and Meta-AnalysisAmerican Journal of Ophthalmology, 2023
- The estimation of approximate sample size requirements necessary for clinical and epidemiological studies in vision sciencesEye, 2009