Richard N. McNeely
Research Subjects
Richard N. McNeely has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Jonathan E. Moore
Cathedral Eye Clinic, Belfast BT1 2LS, UK
2 shared publications - Salissou Moutari
School of Mathematics and Physics, Queen’s University Belfast, Belfast BT7 1NN, Northern Ireland, UK
2 shared publications - Stephen Stewart
Department of Ophthalmology, Tan Tock Seng Hospital, Singapore
2 shared publications Jonathan E Moore
Cathedral Eye Clinic, Belfast, Northern Ireland, UK
1 shared publicationJonathan E. Moore
Cathedral Eye Clinic Belfast Northern Ireland UK
1 shared publicationJonathan Moore
Cathedral Eye Clinic, Belfast, UK
1 shared publication
Latest Publications
- Open Access
- 1 May 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-14
Early Visual Performance and Subjective Experience After Bilateral Implantation of a Novel Fully Refractive Extended Depth of Focus Intraocular Lens
To outline the early postoperative visual performance and subjective quality of vision (QoV) after implantation of a new fully refractive extended depth of focus intraocular lens (IOL). The study enrolled 103 patients undergoing bilateral phacoemulsification with implantation of the Tecnis PureSee IOL (Johnson & Johnson). Refraction, uncorrected (UDVA) and best-corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, defocus curves, electronic reading desk, QoV questionnaire and a halo and glare simulator were evaluated 3 months postoperatively. Mean binocular UDVA, UIVA and UNVA were −0.06 ± 0.07, 0.05 ± 0.08 and 0.20 ± 0.08 logMAR respectively. At 3 months, 83% were within ± 0.50D and 99% within ± 1.00D of the refractive aim. Minimal dysphotopsias and overall QoV scores of 8.68 ± 1.13 for the day and 8.08 ± 1.58 at night were reported. Of all patients, 98.1% reported better vision than preoperatively and 86.4% would recommend the procedure. Spectacle independence for distance, intermediate, and near was achieved in 100%, 94.2% and 66% of patients respectively. The Tecnis PureSee IOL provided excellent distance and intermediate vision with good functional near vision. Patients reported high postoperative QoV and subjective functional vision, with minimal visual side effects.
- 1 May 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-14
Open AccessEarly Visual Performance and Subjective Experience After Bilateral Implantation of a Novel Fully Refractive Extended Depth of Focus Intraocular Lens
To outline the early postoperative visual performance and subjective quality of vision (QoV) after implantation of a new fully refractive extended depth of focus intraocular lens (IOL). The study enrolled 103 patients undergoing bilateral phacoemulsification with implantation of the Tecnis PureSee IOL (Johnson & Johnson). Refraction, uncorrected (UDVA) and best-corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, defocus curves, electronic reading desk, QoV questionnaire and a halo and glare simulator were evaluated 3 months postoperatively. Mean binocular UDVA, UIVA and UNVA were −0.06 ± 0.07, 0.05 ± 0.08 and 0.20 ± 0.08 logMAR respectively. At 3 months, 83% were within ± 0.50D and 99% within ± 1.00D of the refractive aim. Minimal dysphotopsias and overall QoV scores of 8.68 ± 1.13 for the day and 8.08 ± 1.58 at night were reported. Of all patients, 98.1% reported better vision than preoperatively and 86.4% would recommend the procedure. Spectacle independence for distance, intermediate, and near was achieved in 100%, 94.2% and 66% of patients respectively. The Tecnis PureSee IOL provided excellent distance and intermediate vision with good functional near vision. Patients reported high postoperative QoV and subjective functional vision, with minimal visual side effects.
- 4 March 2025
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 53 (5) , 558-569
Cataract Surgery in the Small Adult Eye: A Review
Modern cataract surgery continues to advance, yet intraocular lens (IOL) based surgery in the small adult eye remains challenging. Thorough preoperative assessment and surgical preparation optimise postoperative outcomes in these cases. Advances in IOL power calculation, including artificial intelligence‐driven formulas, improve accuracy; however, careful consideration of biometry and IOL power selection is still necessary because inaccuracies can produce significant errors. Limited availability of high‐powered IOLs to fully correct high refractive errors may necessitate further intervention. Surgical techniques have evolved to address the unique anatomical challenges of small eyes, improving safety and outcomes. Knowledge of the potential risks inherent in these cases can assist the surgeon in modifying the operative technique accordingly. This review discusses essential preoperative assessments, IOL power selection, surgical techniques, and potential complications, offering guidance for surgeons performing cataract surgery on small adult eyes.
- 4 March 2025
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 53 (5) , 558-569
Cataract Surgery in the Small Adult Eye: A Review
Modern cataract surgery continues to advance, yet intraocular lens (IOL) based surgery in the small adult eye remains challenging. Thorough preoperative assessment and surgical preparation optimise postoperative outcomes in these cases. Advances in IOL power calculation, including artificial intelligence‐driven formulas, improve accuracy; however, careful consideration of biometry and IOL power selection is still necessary because inaccuracies can produce significant errors. Limited availability of high‐powered IOLs to fully correct high refractive errors may necessitate further intervention. Surgical techniques have evolved to address the unique anatomical challenges of small eyes, improving safety and outcomes. Knowledge of the potential risks inherent in these cases can assist the surgeon in modifying the operative technique accordingly. This review discusses essential preoperative assessments, IOL power selection, surgical techniques, and potential complications, offering guidance for surgeons performing cataract surgery on small adult eyes.
- Open Access
- 1 January 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 35-43
Effect of Posterior Corneal Surgically Induced Astigmatism on Toric Intraocular Lens Power Calculations
Background: To determine whether accounting for posterior corneal surgically induced astigmatism (SIA) would improve toric intraocular lens power calculation prediction error. Methods: A total of 189 eyes of 148 patients undergoing routine cataract surgery were included in the study. Standard and posterior keratometry were measured pre- and postoperatively. Centroid SIA with standard keratometry and posterior keratometry were calculated separately. Prediction errors for postoperative refractive astigmatism at 4 weeks postoperatively were compared for Barrett Toric with predicted posterior corneal astigmatism (PPCA); Barrett Toric with preoperative measured posterior corneal astigmatism (MPCA); Barrett Toric with postoperative MPCA, which accounts for posterior corneal SIA. Results: There was a significant increase in PCA magnitude postoperatively (p < 0.001), although a change of > 0.3D occurred in only 3% of eyes. There was a postoperative rotation in the steep meridian of > 10° in 32% of eyes. The Barrett Toric formula with PPCA yielded a significantly smaller refractive astigmatism prediction error compared to when a postoperative MPCA value was used (p < 0.01). Postoperative MPCA had a lower proportion of eyes within 0.50, 0.75 and 1.00D of predicted refractive astigmatism than PPCA or preoperative MPCA, although this was not statistically significant. Conclusion: This study demonstrated postoperative changes in posterior corneal astigmatism magnitude and the orientation of the steep meridian. However, accounting for posterior keratometric SIA in the Barrett Toric formula does not improve refractive astigmatism prediction accuracy.
- 1 January 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 35-43
Open AccessEffect of Posterior Corneal Surgically Induced Astigmatism on Toric Intraocular Lens Power Calculations
Background: To determine whether accounting for posterior corneal surgically induced astigmatism (SIA) would improve toric intraocular lens power calculation prediction error. Methods: A total of 189 eyes of 148 patients undergoing routine cataract surgery were included in the study. Standard and posterior keratometry were measured pre- and postoperatively. Centroid SIA with standard keratometry and posterior keratometry were calculated separately. Prediction errors for postoperative refractive astigmatism at 4 weeks postoperatively were compared for Barrett Toric with predicted posterior corneal astigmatism (PPCA); Barrett Toric with preoperative measured posterior corneal astigmatism (MPCA); Barrett Toric with postoperative MPCA, which accounts for posterior corneal SIA. Results: There was a significant increase in PCA magnitude postoperatively (p < 0.001), although a change of > 0.3D occurred in only 3% of eyes. There was a postoperative rotation in the steep meridian of > 10° in 32% of eyes. The Barrett Toric formula with PPCA yielded a significantly smaller refractive astigmatism prediction error compared to when a postoperative MPCA value was used (p < 0.01). Postoperative MPCA had a lower proportion of eyes within 0.50, 0.75 and 1.00D of predicted refractive astigmatism than PPCA or preoperative MPCA, although this was not statistically significant. Conclusion: This study demonstrated postoperative changes in posterior corneal astigmatism magnitude and the orientation of the steep meridian. However, accounting for posterior keratometric SIA in the Barrett Toric formula does not improve refractive astigmatism prediction accuracy.
- Open Access
- 1 June 2022
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 16, 1883-1891
Visual and Refractive Outcomes Following Exchange of an Opacified Multifocal Intraocular Lens
Purpose: To assess the visual and refractive outcomes following exchange of an opacified multifocal intraocular lens (IOL). Patients and Methods: A consecutive series of 37 eyes (31 patients) that underwent IOL exchange between November 2015 and May 2021 were included in this study. The indication for surgery in all cases was opacification of a multifocal IOL. Outcome measures included design and anatomical location of the secondary IOL, intraoperative and postoperative complications, visual acuity and refractive accuracy. Results: An opacified Lentis Mplus multifocal IOL was explanted from all eyes and replaced with a monofocal IOL in 21 eyes (57%) and multifocal IOL in 16 eyes (43%). Secondary IOLs were implanted in the capsular bag or sulcus or were iris-fixated. IOL exchange was performed at a mean interval of 7 years after the primary surgery. Anterior vitrectomy was required for vitreous prolapse in 9 eyes (24%). Mean corrected distance visual acuity (CDVA) postoperatively was − 0.02 ± 0.08 logMAR for eyes with a monofocal secondary IOL and 0.02 ± 0.08 logMAR for eyes with a multifocal secondary IOL. Mean refractive prediction error was − 0.57 ± 0.67 D in the multifocal-monofocal group and − 0.33 ± 0.59 D in the multifocal–multifocal group. Conclusion: An opacified multifocal IOL can be exchanged for a monofocal or multifocal IOL, depending on available capsular support and the patient’s desired refractive outcome. Vitreous prolapse requiring anterior vitrectomy is the most common intraoperative complication. An improvement in visual acuity and a low postoperative complication rate were achieved in this cohort of patients.
- 1 June 2022
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 16, 1883-1891
Open AccessVisual and Refractive Outcomes Following Exchange of an Opacified Multifocal Intraocular Lens
Purpose: To assess the visual and refractive outcomes following exchange of an opacified multifocal intraocular lens (IOL). Patients and Methods: A consecutive series of 37 eyes (31 patients) that underwent IOL exchange between November 2015 and May 2021 were included in this study. The indication for surgery in all cases was opacification of a multifocal IOL. Outcome measures included design and anatomical location of the secondary IOL, intraoperative and postoperative complications, visual acuity and refractive accuracy. Results: An opacified Lentis Mplus multifocal IOL was explanted from all eyes and replaced with a monofocal IOL in 21 eyes (57%) and multifocal IOL in 16 eyes (43%). Secondary IOLs were implanted in the capsular bag or sulcus or were iris-fixated. IOL exchange was performed at a mean interval of 7 years after the primary surgery. Anterior vitrectomy was required for vitreous prolapse in 9 eyes (24%). Mean corrected distance visual acuity (CDVA) postoperatively was − 0.02 ± 0.08 logMAR for eyes with a monofocal secondary IOL and 0.02 ± 0.08 logMAR for eyes with a multifocal secondary IOL. Mean refractive prediction error was − 0.57 ± 0.67 D in the multifocal-monofocal group and − 0.33 ± 0.59 D in the multifocal–multifocal group. Conclusion: An opacified multifocal IOL can be exchanged for a monofocal or multifocal IOL, depending on available capsular support and the patient’s desired refractive outcome. Vitreous prolapse requiring anterior vitrectomy is the most common intraoperative complication. An improvement in visual acuity and a low postoperative complication rate were achieved in this cohort of patients.
- Open Access
- 21 June 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (6) , e0197503
An alternative application of Rasch analysis to assess data from ophthalmic patient-reported outcome instruments
To highlight the potential shortcomings associated with the current use Rasch analysis for validation of ophthalmic questionnaires, and to present an alternative application of Rasch analysis to derive insights specific to the cohort of patients under investigation. An alternative application of Rasch analysis was used to investigate the quality of vision (QoV) for a cohort of 481 patients. Patients received multifocal intraocular lenses and completed a QoV questionnaire one and twelve months post-operatively. The rating scale variant of the polytomous Rasch model was utilized. The parameters of the model were estimated using the joint maximum likelihood estimation. Analysis was performed on data at both post-operative assessments, and the outcomes were compared. The distribution of the location of symptoms altered between assessments with the most annoyed patients completely differing. One month post-operatively, the most prevalent symptom was starbursts compared to glare at twelve months. The visual discomfort from the most annoyed patients is substantially higher at twelve months. The current most advocated approach for validating questionnaires using Rasch analysis found that the questionnaire was “Rasch-valid” one month post-operatively and “Rasch-invalid” twelve months post-operatively. The proposed alternative application of Rasch analysis to questionnaires can be used as an effective decision support tool at population and individual level. At population level, this new approach enables one to investigate the prevalence of symptoms across different cohorts of patients. At individual level, the new approach enables one to identify patients with poor QoV over time. This study highlights some of the potential shortcomings associated with the current use of Rasch analysis to validate questionnaires.
- 21 June 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (6) , e0197503
Open AccessAn alternative application of Rasch analysis to assess data from ophthalmic patient-reported outcome instruments
To highlight the potential shortcomings associated with the current use Rasch analysis for validation of ophthalmic questionnaires, and to present an alternative application of Rasch analysis to derive insights specific to the cohort of patients under investigation. An alternative application of Rasch analysis was used to investigate the quality of vision (QoV) for a cohort of 481 patients. Patients received multifocal intraocular lenses and completed a QoV questionnaire one and twelve months post-operatively. The rating scale variant of the polytomous Rasch model was utilized. The parameters of the model were estimated using the joint maximum likelihood estimation. Analysis was performed on data at both post-operative assessments, and the outcomes were compared. The distribution of the location of symptoms altered between assessments with the most annoyed patients completely differing. One month post-operatively, the most prevalent symptom was starbursts compared to glare at twelve months. The visual discomfort from the most annoyed patients is substantially higher at twelve months. The current most advocated approach for validating questionnaires using Rasch analysis found that the questionnaire was “Rasch-valid” one month post-operatively and “Rasch-invalid” twelve months post-operatively. The proposed alternative application of Rasch analysis to questionnaires can be used as an effective decision support tool at population and individual level. At population level, this new approach enables one to investigate the prevalence of symptoms across different cohorts of patients. At individual level, the new approach enables one to identify patients with poor QoV over time. This study highlights some of the potential shortcomings associated with the current use of Rasch analysis to validate questionnaires.