Imaging of fragment particles in water by nuclear spallation during carbon-ion irradiation
- 1 July 2019
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (13) , 13NT01
Abstract
Recently we found that the luminescence imaging of water during carbon-ion irradiation was possible using a cooled charge-coupled device (CCD) camera and the method could be used for range estimation of the beam. In the luminescence image, we found luminescence from the fragment particles produced by the nuclear spallation reaction of carbon ions. The luminescence may be used for the estimation of the distribution of the fragment particles by the nuclear spallation. For this purpose, we irradiated carbon ions of 241.5 MeV u −1 to a water phantom and measured the luminescence image of water using a CCD camera. Then, we carefully observed the luminescence distribution after the Bragg peak to find the luminescence from the nuclear spallation reaction. In the luminescence image, we could clearly observe the luminescence from the fragment particles produced by the nuclear spallation reaction during irradiation of carbon ions. The beam widths of the luminescence image of the nuclear spallation were compared with those measured by the ionization chamber. The relative difference of the beam width at FWHM between luminescence image and ionization chamber was 23%. With these results, we conclude that the luminescence image of water during carbon-ion irradiation has a potential to be a new and efficient method for the width estimation of the fragment particles by the nuclear spallation reaction.Keywords
Funding Information
- Japan Society for the Promotion of Science (JP16H03908, JP25253077)
This publication has 11 references indexed in Scilit:
- Addition of luminescence process in Monte Carlo simulation to precisely estimate the light emitted from water during proton and carbon-ion irradiationPhysics in Medicine & Biology, 2018
- Estimation of the optical errors on the luminescence imaging of water for proton beamNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2018
- Scintillation imaging of air during proton and carbon-ion beam irradiationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Nuclear physics in particle therapy: a reviewReports on Progress in Physics, 2016
- Luminescence imaging of water during carbon-ion irradiation for range estimationMedical Physics, 2016
- Luminescence imaging of water during proton‐beam irradiation for range estimationMedical Physics, 2015
- Implementation of a triple Gaussian beam model with subdivision and redefinition against density heterogeneities in treatment planning for scanned carbon-ion radiotherapyPhysics in Medicine & Biology, 2014
- Field‐size effect of physical doses in carbon‐ion scanning using range shifter platesMedical Physics, 2009
- Dose contributions from large-angle scattered particles in therapeutic carbon beamsMedical Physics, 2006
- Spatial fragment distribution from a therapeutic pencil-like carbon beam in waterPhysics in Medicine & Biology, 2005