  • Luminescence imaging of water irradiated by protons under FLASH radiation therapy conditions

    by Katsunori Yogo, Satoshi Kodaira, Tamon Kusumoto, Hisashi Kitamura, Toshiyuki Toshito, Hiromitsu Iwata, Masumi Umezawa, Masashi Yamada, Takuto Miyoshi, Masataka Komori, et al.

    Objective. FLASH radiation therapy with ultrahigh dose rates (UHDR) has the potential to reduce damage to normal tissue while maintaining anti-tumor efficacy. However, rapid and precise dose distribution measurements remain difficult for FLASH radiation therapy with proton beams. To solve this problem, we performed luminescence imaging of water following irradiation by a UHDR proton beam captured using a charge-coupled device camera. Approach. We used 60 MeV proton beams with dose rates of 0.03–837 Gy s−1 from a cyclotron. Therapeutic 139.3 MeV proton beams with dose rates of 0.45–4320 Gy s−1 delivered by a synchrotron-based proton therapy system were also tested. The luminescent light intensity induced by the UHDR beams was compared with that produced by conventional beams to compare the dose rate dependency of the light intensity and its profile. Main results. Luminescence images of water were clearly visualized under UHDR conditions, with significantly shorter exposure times than those with conventional beams. The light intensity was linearly proportional to the delivered dose, which is similar to that of conventional beams. No significant dose-rate dependency was observed for 0.03–837 Gy s−1. The light-intensity profiles of the UHDR beams agreed with those of conventional beams. The results did not differ between accelerators (synchrotron or cyclotron) and beam energies. Significance. Luminescence imaging of water is achievable with UHDR proton beams as well as with conventional beams. The proposed method should be suitable for rapid and easy quality assurance investigations for proton FLASH therapy, because it facilitates real-time, filmless measurements of dose distributions, and is useful for rapid feedback.


  • Development of an x-ray-opaque-marker system for quantitative phantom positioning in patient-specific quality assurance

    by Kentaro Suzuki, Takeshi Kamomae, Hiroshi Oguchi, Fumitaka Kawabata, Kazuma Sugita, Kuniyasu Okudaira, Masaki Mori, Shinji Abe, Masataka Komori, Mariko Kawamura, et al.


  • Open Access

    Radioluminescence by synchrotron radiation with lower energy than the Cherenkov light threshold in water

    by Yoshiyuki Hirano, Masataka Komori, Daichi Onoda, Takayuki Nagae, Seiichi Yamamoto

    Radioluminescence by protons and carbon ions of energy lower than the Cherenkov threshold (∼260 keV) in water has been observed. However, the origin of the luminescence has not been investigated well. In the present work, we imaged radioluminescence in water using synchrotron radiation that was of sufficiently lower energy (11 keV) than the Cherenkov threshold and we measured its spectrum using a high-sensitivity cooled CCD camera and optical longpass filters having 5 different thresholds. In addition, to determine effects of impurities in water, the water target was changed from ultrapure water to tap water. Monte Carlo simulation (Geant4) was also performed to compare its results with the experimentally obtained radioluminescence distribution. In the simulation, photons were generated in proportion to the energy deposition in water. As a result, the beam trajectory was clearly imaged by the radioluminescence in water. The spectrum was proportional to λ −3.4±0.4 under an assumption of no peaks. In the spectrum and distribution, no differences were observed between ultrapure water and tap water. TOC (total organic carbon) contents of ultrapure water and tap water as an impurity were measured and these were 0.26 mg l−1 and 2.3 mg l−1, respectively. The radioluminescence seemed to be attributable to water molecules not impurities. The radioluminescence distribution of the simulation was consistent with the experimental distribution and this suggested that radioluminescence was proportional to dose, which is expected to allow use for dose measurement.


  • Measurements of temporal response of luminescence of water at lower energy than Cerenkov-light threshold during carbon-ion irradiation

    by Seiichi Yamamoto, Takashi Akagi, Yoshiyuki Hirano, Masataka Komori

    Although the luminescence of water at lower energy than the Cerenkov-light threshold during carbon-ion irradiation was found and imaging was possible, the temporal response has not been measured, and so the difference from Cerenkov-light remains unclear. To clarify this point, we measured the temporal response of the luminescence of water at lower energy than the Cerenkov-light threshold and compared it with that of Cerenkov-light. We used silicon photomultiplier (Si-PM) modules to measure the temporal response at the Bragg peak area of a water phantom during irradiation of the carbon ion where the Cerenkov-light was not included. We also measured the temporal response at the shallow depth of the water phantom where the Cerenkov-light was included. In both areas, we measured the temporal waveforms of the light produced by the irradiation of the carbon ions in which the ripples of spills were clearly observed. We found no difference in the waveforms between the Bragg peak and the shallow depths of water. Our results do not contradict the hypothesis that the luminescence of water and Cerenkov-light are produced by the same mechanism.


  • Imaging of fragment particles in water by nuclear spallation during carbon-ion irradiation

    by Takuya Yabe, Masataka Komori, Takashi Akagi, Tomohiro Yamashita, Seiichi Yamamoto

    Recently we found that the luminescence imaging of water during carbon-ion irradiation was possible using a cooled charge-coupled device (CCD) camera and the method could be used for range estimation of the beam. In the luminescence image, we found luminescence from the fragment particles produced by the nuclear spallation reaction of carbon ions. The luminescence may be used for the estimation of the distribution of the fragment particles by the nuclear spallation. For this purpose, we irradiated carbon ions of 241.5 MeV u −1 to a water phantom and measured the luminescence image of water using a CCD camera. Then, we carefully observed the luminescence distribution after the Bragg peak to find the luminescence from the nuclear spallation reaction. In the luminescence image, we could clearly observe the luminescence from the fragment particles produced by the nuclear spallation reaction during irradiation of carbon ions. The beam widths of the luminescence image of the nuclear spallation were compared with those measured by the ionization chamber. The relative difference of the beam width at FWHM between luminescence image and ionization chamber was 23%. With these results, we conclude that the luminescence image of water during carbon-ion irradiation has a potential to be a new and efficient method for the width estimation of the fragment particles by the nuclear spallation reaction.


  • Three-dimensional (3D) dose distribution measurements of proton beam using a glass plate

    by Ryo Horita, Seiichi Yamamoto, Katsunori Yogo, Masataka Komori, Toshiyuki Toshito

    The measurements of the three-dimensional (3D) dose distribution of proton beams in water are critical for proton therapy for quality assessment (QA). Although ionization chambers are commonly used for this purpose, such measurements take a long time to calculate precise 3D dose distribution. To solve this problem, we measured 3D dose distributions using a glass plate. We placed a 1-mm thick float glass plate on the upper inside of a black box with a water tank set above the float glass plate outside the black box and irradiated the proton beam to the water tank from the upper side. The attenuated proton beam by water in the tank was detected by the float glass plate and a scintillation image was formed in the plate. The image was reflected by a first-surface mirror set below the float glass plate and detected by a cooled charge-coupled device (CCD) camera from the side. We changed the water depths in the tank and measured the scintillation images at each depth. Then we calculated the 3D scintillation images from the measured images by stacking them in the depth direction. Measurements were made for 71.2- and 100-MeV proton pencil beams and a spread-out Bragg peak (SOBP) using the imaging system. From the images, we successfully formed 3D scintillation images without quenching. The depth profiles measured from the scintillation images showed almost identical distribution with those measured by the ionization chamber within a maximum difference less than 5%. The lateral profiles were also almost identical within width differences less than 2 mm. We conclude that our proposed method is promising for the 3D dose distribution measurements of proton beams.


  • OPTIMIZATION OF AN ADDITIONAL COLLIMATOR IN A BEAM DELIVERY SYSTEM FOR REDUCTION OF THE SECONDARY NEUTRON EXPOSURE IN PASSIVE CARBON-ION THERAPY

    by Masataka Komori, Akihiko Takeuchi, Maiko Niwa, Takaomi Harada, Hiroshi Oguchi

    The aim of this work is to optimize an additional collimator in a beam delivery system to reduce neutron exposure to patients in passive carbon-ion therapy. All studies were performed by Monte Carlo simulation assuming the beam delivery system at Heavy-Ion Medical Accelerator in Chiba. We calculated the neutron ambient dose equivalent at patient positions with an additional collimator, and optimized the position, aperture size and material of the collimator to reduce the neutron ambient dose equivalent. The collimator located 125 and 470 cm upstream from the isocenter could reduce the dose equivalent near the isocenter by 35%, while the collimator located 813 cm upstream from the isocenter was ineffective. As for the material of the collimator, iron and nickel could conduct reduction slightly better than aluminum and polymethyl methacrylate. The additional collimator is an effective method for the reduction of the neutron ambient dose equivalent near the isocenter.


  • Addition of luminescence process in Monte Carlo simulation to precisely estimate the light emitted from water during proton and carbon-ion irradiation

    by Takuya Yabe, Makoto Sasano, Yoshiyuki Hirano, Toshiyuki Toshito, Takashi Akagi, Tomohiro Yamashita, Masateru Hayashi, Tetsushi Azuma, Yusuku Sakamoto, Masataka Komori, et al.

    Although luminescence of water lower in energy than the Cerenkov-light threshold during proton and carbon-ion irradiation has been found, the phenomenon has not yet been implemented for Monte Carlo simulations. The results provided by the simulations lead to misunderstandings of the physical phenomenon in optical imaging of water during proton and carbon-ion irradiation. To solve the problems, as well as to clarify the light production of the luminescence of water, we modified a Monte Carlo simulation code to include the light production from the luminescence of water and compared them with the experimental results of luminescence imaging of water. We used GEANT4 for the simulation of emitted light from water during proton and carbon-ion irradiation. We used the light production from the luminescence of water using the scintillation process in GEANT4 while those of Cerenkov light from the secondary electrons and prompt gamma photons in water were also included in the simulation. The modified simulation results showed similar depth profiles to those of the measured data for both proton and carbon-ion. When the light production of 0.1 photons/MeV was used for the luminescence of water in the simulation, the simulated depth profiles showed the best match to those of the measured results for both the proton and carbon-ion compared with those used for smaller and larger numbers of photons/MeV. We could successively obtain the simulated depth profiles that were basically the same as the experimental data by using GEANT4 when we assumed the light production by the luminescence of water. Our results confirmed that the inclusion of the luminescence of water in Monte Carlo simulation is indispensable to calculate the precise light distribution in water during irradiation of proton and carbon-ion.


  • Open Access

    Source of luminescence of water lower energy than the Cerenkov-light threshold during irradiation of carbon-ion

    by Seiichi Yamamoto, Takashi Akagi, Tomohiro Yamashita, Juha Toivonen, Mitsutaka Yamaguchi, Masataka Komori, Naoki Kawachi

    Although luminescence of water during irradiations of proton and carbon-ion lower energy than the Cerenkov-light threshold were found recently, the sources of the luminescence were not yet obvious. To estimate the sources of the luminescence, we measured the light spectrum of the luminescence of water during carbon-ion irradiations and estimated the sources of the luminescence. Using an ultraviolet (UV) light sensitive charge coupled device (CCD) camera, we measured the luminescence images of water during carbon-ion beam irradiations by changing optical filters, derived the light spectra of the luminescence of water and compared with the calculated results. The intensity of the measured light spectrum of the luminescence of water at the Bragg peak region was decreased as the wavelength of light proportional to ~λ −2.0 where λ is the wavelength of the light, indicating the source of the luminescence of water can be electromagnetic pulse produced by the dipole displacement inside the water molecules. In the shallow part of the water prior to the Bragg peak, where the Cerenkov-light is included, the spectrum showed steeper curve that is proportional to ~λ −2.6, which was similar to the calculated spectrum of Cerenkov-light including the refractive index changes of water with the wavelength of light. From these results, the luminescence of water is thought to be mainly come from electromagnetic pulse produced by the dipole displacement inside the water molecules.