Study of the radiofrequency‐induced heating inside the human head with dental implants at 7 T
- 20 October 2023
- journal article
- research article
- Published by Wiley in Bioelectromagnetics
- Vol. 45 (2) , 82-93
Abstract
Conductive dental implants are commonly used in restorative therapy to replace missing teeth in patients. Ensuring the radiofrequency (RF) safety of these patients is crucial when performing 7 T magnetic resonance scans of their heads. This study aimed to investigate RF‐induced heating inside the human head with dental implants at 7 T. Dental implants and their attachments were fabricated and integrated into an anatomical head model, creating different measurement configurations (MCs). Numerical simulations were conducted using a 7 T transmit coil loaded with the anatomical head model, both with and without dental implants. The maximum temperatures inside the head for various MCs were computed using the maximum permissible input powers (MPIPs) obtained without dental implants and compared with published limits. Additionally, the MPIPs with dental implants were calculated for scenarios where the temperature limits were exceeded. The maximum temperatures observed inside the head ranged from 38.4°C to 39.6°C. The MPIPs in the presence of dental implants were 81.9%–97.3% of the MPIPs in the absence of dental implants for scenarios that exceeded the regulatory limit. RF‐induced heating effect of the dental implants was not significant. The safe scanning condition in terms of RF exposure was achievable for patients with dental implants. For patients with conductive dental implants of unknown configuration, it is recommended to reduce the input power by 18.1% of MPIP without dental implants to ensure RF safety.Keywords
Funding Information
- National Natural Science Foundation of China (61671229, 61929101)
This publication has 37 references indexed in Scilit:
- Management of long span partially edentulous maxilla with fixed removable denture prosthesisContemporary Clinical Dentistry, 2012
- Conductivity and permittivity imaging at 3.0 tConcepts in Magnetic Resonance Part B, 2012
- The Virtual Family—development of surface-based anatomical models of two adults and two children for dosimetric simulationsPhysics in Medicine & Biology, 2009
- Prosthetically Driven, Computer‐Guided Implant Planning for the Edentulous Maxilla: A Model StudyClinical Implant Dentistry and Related Research, 2009
- A NEUROBIOLOGICAL BASIS FOR ELF GUIDELINESHealth Physics, 2007
- Specific absorption rate and temperature elevation in a subject exposed in the far-field of radio-frequency sources operating in the 10-900-MHz rangeIEEE Transactions on Biomedical Engineering, 2003
- SAR and B1 field distributions in a heterogeneous human head model within a birdcage coilMagnetic Resonance in Medicine, 1998
- Mechanical properties of biomedical titanium alloysMaterials Science and Engineering: A, 1998
- Computation of electromagnetic fields for high-frequency magnetic resonance imaging applicationsPhysics in Medicine & Biology, 1996
- Edentulousness—an oral handicap. Patient reactions to treatment with iawbone‐anchored prosthesesJournal of Oral Rehabilitation, 1987