Sherman Xuegang Xin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sherman Xuegang Xin has a total of 125 co-authors. Here are the top co-authors by number of shared publications:
Tianqi Liu
School of Medicine, South China University of Technology
5 shared publications- Feng Liu
University of Queensland
4 shared publications Ruiting Zhao
School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, Guangdong, China
3 shared publicationsShengnan Tang
School of Medicine, South China University of Technology, Guangdong, People’s Republic of China
3 shared publicationsSong Duan
Department of Radiation Oncology Sun Yat‐sen Memorial Hospital of Sun Yat‐sen University Guangzhou China
3 shared publicationsXinhua Wei
Department of Radiology, Guangzhou First People's Hospital, South China University of Technology, Guangzhou 510180, Guangdong, China
3 shared publications
Latest Publications
- Open Access
- 22 April 2026
- Published by Springer Nature in Cellular and Molecular Bioengineering
- Vol. 19 (2) , 1
Publisher Correction: Multiscale ECM Stiffness Characterization and Quantitative Single-Cell Analysis Reveal ITGA3-Mediated Stiffness-Responsive Subpopulation Dynamics in Papillary Thyroid Carcinoma
- 22 April 2026
- Published by Springer Nature in Cellular and Molecular Bioengineering
- Vol. 19 (2) , 1
Open AccessPublisher Correction: Multiscale ECM Stiffness Characterization and Quantitative Single-Cell Analysis Reveal ITGA3-Mediated Stiffness-Responsive Subpopulation Dynamics in Papillary Thyroid Carcinoma
- 9 March 2026
- Published by Springer Nature in Cellular and Molecular Bioengineering
- Vol. 19 (2) , 191-203
Multiscale ECM Stiffness Characterization and Quantitative Single-Cell Analysis Reveal ITGA3-Mediated Stiffness-Responsive Subpopulation Dynamics in Papillary Thyroid Carcinoma
Extracellular matrix (ECM) stiffening is a defining feature of papillary thyroid carcinoma (PTC) and influences the emergence of cancer cell subpopulations with distinct behaviors. While tissue-scale measurements provide important insights, they do not capture the local stiffness at the cellular scale, which defines the microenvironment that guides subpopulation organization through integrin-dependent mechanotransduction. This study aimed to quantitatively assess ECM stiffness across tissue and cellular scales and investigate how it shapes PTC subpopulation composition, focusing on integrin α3 (ITGA3) as a key mediator of stiffness-responsive cellular remodeling. Human PTC tissues were examined to assess ECM stiffness at multiple scales and to evaluate ITGA3 expression. A stiffness-mimicking hydrogel system was used to investigate how modulation of ITGA3 influences cellular responses to matrix rigidity. Single-cell imaging and computational analyses were applied to resolve stiffness-responsive cell-state patterns, and additional experiments were performed to further examine adhesion-associated functional effects. ECM stiffness was elevated at both tissue and cellular scales in human PTC. Experimental models reproducing these stiffness conditions revealed that ITGA3 is required for cells to properly respond to a stiff mechanical environment. Single-cell analyses identified distinct stiffness-responsive subpopulations, and loss of ITGA3 disrupted their redistribution across different mechanical conditions. Additional perturbation experiments further supported a central role for ITGA3 in stiffness-responsive remodeling of cell states. This study integrates multi-scale stiffness measurements with single-cell analysis to reveal how ECM mechanics influence phenotypic heterogeneity in PTC. By identifying ITGA3 as a key mediator of stiffness-responsive remodeling, our findings link matrix stiffness with the organization of distinct cellular subpopulations. Together, these results provide conceptual insight into how the mechanical microenvironment shapes cell behavior in PTC. The online version contains supplementary material available at 10.1007/s12195-026-00895-0.
- 9 March 2026
- Published by Springer Nature in Cellular and Molecular Bioengineering
- Vol. 19 (2) , 191-203
Multiscale ECM Stiffness Characterization and Quantitative Single-Cell Analysis Reveal ITGA3-Mediated Stiffness-Responsive Subpopulation Dynamics in Papillary Thyroid Carcinoma
Extracellular matrix (ECM) stiffening is a defining feature of papillary thyroid carcinoma (PTC) and influences the emergence of cancer cell subpopulations with distinct behaviors. While tissue-scale measurements provide important insights, they do not capture the local stiffness at the cellular scale, which defines the microenvironment that guides subpopulation organization through integrin-dependent mechanotransduction. This study aimed to quantitatively assess ECM stiffness across tissue and cellular scales and investigate how it shapes PTC subpopulation composition, focusing on integrin α3 (ITGA3) as a key mediator of stiffness-responsive cellular remodeling. Human PTC tissues were examined to assess ECM stiffness at multiple scales and to evaluate ITGA3 expression. A stiffness-mimicking hydrogel system was used to investigate how modulation of ITGA3 influences cellular responses to matrix rigidity. Single-cell imaging and computational analyses were applied to resolve stiffness-responsive cell-state patterns, and additional experiments were performed to further examine adhesion-associated functional effects. ECM stiffness was elevated at both tissue and cellular scales in human PTC. Experimental models reproducing these stiffness conditions revealed that ITGA3 is required for cells to properly respond to a stiff mechanical environment. Single-cell analyses identified distinct stiffness-responsive subpopulations, and loss of ITGA3 disrupted their redistribution across different mechanical conditions. Additional perturbation experiments further supported a central role for ITGA3 in stiffness-responsive remodeling of cell states. This study integrates multi-scale stiffness measurements with single-cell analysis to reveal how ECM mechanics influence phenotypic heterogeneity in PTC. By identifying ITGA3 as a key mediator of stiffness-responsive remodeling, our findings link matrix stiffness with the organization of distinct cellular subpopulations. Together, these results provide conceptual insight into how the mechanical microenvironment shapes cell behavior in PTC. The online version contains supplementary material available at 10.1007/s12195-026-00895-0.
- Open Access
- 11 September 2025
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 42 (1) , 2555683
Method for fabricating tissue-mimicking materials with designated dielectric and thermal properties for radiofrequency ablation
This study presents a novel method for fabricating polyacrylamide-based tissue-mimicking materials with designated dielectric and thermal properties, designed to address the existing gap in tools that can accurately assess heat generation, transfer, and distribution during radiofrequency ablation procedures. The dielectric and thermal properties of the materials were tuned by varying the concentrations of ethylene glycol, aluminum oxide, and sodium chloride. A total of 27 samples were fabricated, and their properties were measured at four RFA-relevant temperatures (45 °C, 60 °C, 75 °C, and 90 °C). Regression models were developed to quantitatively predict these properties based on the component concentrations. To validate the models, four additional samples were fabricated to mimic the dielectric and thermal properties of liver tissue at each of the four temperatures. Short-term stability was assessed by storing these validation samples at 4 °C for two weeks and repeating the measurements. The regression models achieved coefficients of determination (R2) above 0.87, 0.99, and 0.91 for electrical conductivity, thermal conductivity, and volumetric heat capacity, respectively. Validation experiments showed that measured properties deviated from reference liver tissue values by less than 6%, surpassing previous studies in accuracy. After two weeks of storage, relative errors remained below 10%, confirming short-term stability. This study demonstrates an effective method for fabricating tissue-mimicking phantoms with designated dielectric and thermal properties, contributing to the advancement of phantoms for radiofrequency ablation research.
- 11 September 2025
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 42 (1) , 2555683
Open AccessMethod for fabricating tissue-mimicking materials with designated dielectric and thermal properties for radiofrequency ablation
This study presents a novel method for fabricating polyacrylamide-based tissue-mimicking materials with designated dielectric and thermal properties, designed to address the existing gap in tools that can accurately assess heat generation, transfer, and distribution during radiofrequency ablation procedures. The dielectric and thermal properties of the materials were tuned by varying the concentrations of ethylene glycol, aluminum oxide, and sodium chloride. A total of 27 samples were fabricated, and their properties were measured at four RFA-relevant temperatures (45 °C, 60 °C, 75 °C, and 90 °C). Regression models were developed to quantitatively predict these properties based on the component concentrations. To validate the models, four additional samples were fabricated to mimic the dielectric and thermal properties of liver tissue at each of the four temperatures. Short-term stability was assessed by storing these validation samples at 4 °C for two weeks and repeating the measurements. The regression models achieved coefficients of determination (R2) above 0.87, 0.99, and 0.91 for electrical conductivity, thermal conductivity, and volumetric heat capacity, respectively. Validation experiments showed that measured properties deviated from reference liver tissue values by less than 6%, surpassing previous studies in accuracy. After two weeks of storage, relative errors remained below 10%, confirming short-term stability. This study demonstrates an effective method for fabricating tissue-mimicking phantoms with designated dielectric and thermal properties, contributing to the advancement of phantoms for radiofrequency ablation research.
- 28 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (17) , 32822-32830
Research on the Finite-Length Probes Related Accuracy of the Measurement of Biological Tissue Thermal Properties Using DPHP Method With CPC Model
The safety and effectiveness of the radio frequency ablation (RFA) depend on the accurate measurement of the thermal properties of tissues. Although the dual-probe heat-pulse (DPHP) method with the cylindrical-perfect-conductors (CPCs) model is widely used for characterizing biological tissues, its accuracy is inherently limited by the model’s neglect of probe length effects. In this study, we used finite element method to investigate the impact of finite-length probes on the accuracy of measurement using DPHP method with the CPCs model. The simulation indicated an overestimation of diffusivity and volumetric heat capacity due to finite-length probes. For probes with the length of 10, 20, and 30 mm, the relative errors in diffusivity reach 9%, 3%, and 1.5%, respectively, while the relative errors in volumetric heat capacity reach 19%, 8%, and 5%, respectively. Based on the simulation, we presented a novel compensation for the errors caused by finite-length probes in the measurement of biological tissues. We conducted measurement of tissue-mimicking phantom to validate the effectiveness of the compensation. The results demonstrate that after applying the compensation, the measurement errors of volumetric heat capacity were reduced from 6.96% to 0.82% with the use of 20-mm probes, and from 4.46% to 1.11% with the use of 30-mm probes.
- 28 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (17) , 32822-32830
Research on the Finite-Length Probes Related Accuracy of the Measurement of Biological Tissue Thermal Properties Using DPHP Method With CPC Model
The safety and effectiveness of the radio frequency ablation (RFA) depend on the accurate measurement of the thermal properties of tissues. Although the dual-probe heat-pulse (DPHP) method with the cylindrical-perfect-conductors (CPCs) model is widely used for characterizing biological tissues, its accuracy is inherently limited by the model’s neglect of probe length effects. In this study, we used finite element method to investigate the impact of finite-length probes on the accuracy of measurement using DPHP method with the CPCs model. The simulation indicated an overestimation of diffusivity and volumetric heat capacity due to finite-length probes. For probes with the length of 10, 20, and 30 mm, the relative errors in diffusivity reach 9%, 3%, and 1.5%, respectively, while the relative errors in volumetric heat capacity reach 19%, 8%, and 5%, respectively. Based on the simulation, we presented a novel compensation for the errors caused by finite-length probes in the measurement of biological tissues. We conducted measurement of tissue-mimicking phantom to validate the effectiveness of the compensation. The results demonstrate that after applying the compensation, the measurement errors of volumetric heat capacity were reduced from 6.96% to 0.82% with the use of 20-mm probes, and from 4.46% to 1.11% with the use of 30-mm probes.
- Open Access
- 16 June 2025
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 318, 145309
Low molecular weight fucoidan: Production methods and their therapeutic applications
- 16 June 2025
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 318, 145309
Open AccessLow molecular weight fucoidan: Production methods and their therapeutic applications
- Open Access
- 6 November 2024
- Published by Springer Nature in npj Systems Biology and Applications
- Vol. 10 (1) , 1-10
Exploring heterogeneous cell population dynamics in different microenvironments by novel analytical strategy based on images
Understanding the dynamic states and transitions of heterogeneous cell populations is crucial for addressing fundamental biological questions. High-content imaging provides rich datasets, but it remains increasingly difficult to integrate and annotate high-dimensional and time-resolved datasets to profile heterogeneous cell population dynamics in different microenvironments. Using hepatic stellate cells (HSCs) LX-2 as model, we proposed a novel analytical strategy for image-based integration and annotation to profile dynamics of heterogeneous cell populations in 2D/3D microenvironments. High-dimensional features were extracted from extensive image datasets, and cellular states were identified based on feature profiles. Time-series clustering revealed distinct temporal patterns of cell shape and actin cytoskeleton reorganization. We found LX-2 showed more complex membrane dynamics and contractile systems with an M-shaped actin compactness trend in 3D culture, while they displayed rapid spreading in early 2D culture. This image-based integration and annotation strategy enhances our understanding of HSCs heterogeneity and dynamics in complex extracellular microenvironments.
- 6 November 2024
- Published by Springer Nature in npj Systems Biology and Applications
- Vol. 10 (1) , 1-10
Open AccessExploring heterogeneous cell population dynamics in different microenvironments by novel analytical strategy based on images
Understanding the dynamic states and transitions of heterogeneous cell populations is crucial for addressing fundamental biological questions. High-content imaging provides rich datasets, but it remains increasingly difficult to integrate and annotate high-dimensional and time-resolved datasets to profile heterogeneous cell population dynamics in different microenvironments. Using hepatic stellate cells (HSCs) LX-2 as model, we proposed a novel analytical strategy for image-based integration and annotation to profile dynamics of heterogeneous cell populations in 2D/3D microenvironments. High-dimensional features were extracted from extensive image datasets, and cellular states were identified based on feature profiles. Time-series clustering revealed distinct temporal patterns of cell shape and actin cytoskeleton reorganization. We found LX-2 showed more complex membrane dynamics and contractile systems with an M-shaped actin compactness trend in 3D culture, while they displayed rapid spreading in early 2D culture. This image-based integration and annotation strategy enhances our understanding of HSCs heterogeneity and dynamics in complex extracellular microenvironments.
- Open Access
- 18 September 2024
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 70 (1) , 49-59
Evaluation of the RF depositions at 3T in routine clinical scans with respect to the SAR safety to improve efficiency of MRI utilization
Objectives: This study explores the potential for improving of 3T MRI utilization by assessing and tailoring RF exposure in routine clinical scans while complying to standard safety limit. Methods: Using two generic human body models, we evaluated pbSAR10g values at four landmark positions (knee, pelvis, thoracic spine, head) at different wbSAR levels. Specifically, we analyzed local SAR10g in different operating modes and computed the maximum safety wbSAR, ensuring compliance with IEC limits. Results: In normal operating mode, the RF power deposition reached wbSAR limit before the pbSAR10g limit. In the first level controlled operating mode, pbSAR10g limit is reached before the wbSAR limit in the knee, thoracic spine scanning scenarios, while the wbSAR limit is reached first in the pelvis scanning scenarios, making it the most potential-releasing (up to 33.33 %) scanning scenario. For head exposure, the head SAR10g limit is reached before the wbSAR limit, highlighting the necessity for strict SAR control. Moreover, we calculated the minimum allowable TR for common imaging sequences for reference. Conclusions: Different RF exposure setups are necessary to meet safety standards in various scenarios. By implementing careful RF exposure setups in routine clinical scans, the high potential capacity of 3T MRI can be fully released.
- 18 September 2024
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 70 (1) , 49-59
Open AccessEvaluation of the RF depositions at 3T in routine clinical scans with respect to the SAR safety to improve efficiency of MRI utilization
Objectives: This study explores the potential for improving of 3T MRI utilization by assessing and tailoring RF exposure in routine clinical scans while complying to standard safety limit. Methods: Using two generic human body models, we evaluated pbSAR10g values at four landmark positions (knee, pelvis, thoracic spine, head) at different wbSAR levels. Specifically, we analyzed local SAR10g in different operating modes and computed the maximum safety wbSAR, ensuring compliance with IEC limits. Results: In normal operating mode, the RF power deposition reached wbSAR limit before the pbSAR10g limit. In the first level controlled operating mode, pbSAR10g limit is reached before the wbSAR limit in the knee, thoracic spine scanning scenarios, while the wbSAR limit is reached first in the pelvis scanning scenarios, making it the most potential-releasing (up to 33.33 %) scanning scenario. For head exposure, the head SAR10g limit is reached before the wbSAR limit, highlighting the necessity for strict SAR control. Moreover, we calculated the minimum allowable TR for common imaging sequences for reference. Conclusions: Different RF exposure setups are necessary to meet safety standards in various scenarios. By implementing careful RF exposure setups in routine clinical scans, the high potential capacity of 3T MRI can be fully released.
- Open Access
- 10 July 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (7) , 699
Using the Probability Density Function-Based Channel-Combination Bloch–Siegert Method Realizes Permittivity Imaging at 3T
Magnetic resonance electrical properties tomography (MR EPT) can retrieve permittivity from the magnitude. However, the accuracy of the permittivity measurement using MR EPT is still not ideal due to the low signal-to-noise ratio (SNR) of magnitude. In this study, the probability density function (PDF)-based channel-combination Bloch–Siegert (BSS) method was firstly introduced to MR EPT for improving the accuracy of the permittivity measurement. MRI experiments were performed using a 3T scanner with an eight-channel receiver coil. The homogeneous water phantom was scanned for assessing the spatial distribution of magnitude obtained from the PDF-based channel-combination BSS method. Gadolinium (Gd) phantom and rats were scanned for assessing the feasibility of the PDF-based channel-combination BSS method in MR EPT. The Helmholtz-based EPT reconstruction algorithm was selected. For quantitative comparison, the permittivity measured by the open-ended coaxial probe method was considered as the ground-truth value. The accuracy of the permittivity measurement was estimated by the relative error between the reconstructed value and the ground-truth value. The reconstructed relative permittivity of Gd phantom was 52.413, while that of rat leg muscle was 54.053. The ground-truth values of relative permittivity of Gd phantom and rat leg muscle were 78.86 and 49.04, respectively. The relative error of average permittivity was 33.53% for Gd and 10.22% for rat leg muscle. The results indicated the high accuracy of the permittivity measurement using the PDF-based channel-combination BSS method in MR EPT. This improvement may promote the clinical application of MR EPT technology, such as in the early diagnosis of cancers.- 10 July 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (7) , 699
Open AccessUsing the Probability Density Function-Based Channel-Combination Bloch–Siegert Method Realizes Permittivity Imaging at 3T
Magnetic resonance electrical properties tomography (MR EPT) can retrieve permittivity from the magnitude. However, the accuracy of the permittivity measurement using MR EPT is still not ideal due to the low signal-to-noise ratio (SNR) of magnitude. In this study, the probability density function (PDF)-based channel-combination Bloch–Siegert (BSS) method was firstly introduced to MR EPT for improving the accuracy of the permittivity measurement. MRI experiments were performed using a 3T scanner with an eight-channel receiver coil. The homogeneous water phantom was scanned for assessing the spatial distribution of magnitude obtained from the PDF-based channel-combination BSS method. Gadolinium (Gd) phantom and rats were scanned for assessing the feasibility of the PDF-based channel-combination BSS method in MR EPT. The Helmholtz-based EPT reconstruction algorithm was selected. For quantitative comparison, the permittivity measured by the open-ended coaxial probe method was considered as the ground-truth value. The accuracy of the permittivity measurement was estimated by the relative error between the reconstructed value and the ground-truth value. The reconstructed relative permittivity of Gd phantom was 52.413, while that of rat leg muscle was 54.053. The ground-truth values of relative permittivity of Gd phantom and rat leg muscle were 78.86 and 49.04, respectively. The relative error of average permittivity was 33.53% for Gd and 10.22% for rat leg muscle. The results indicated the high accuracy of the permittivity measurement using the PDF-based channel-combination BSS method in MR EPT. This improvement may promote the clinical application of MR EPT technology, such as in the early diagnosis of cancers. - 20 October 2023
- Published by Wiley in Bioelectromagnetics
- Vol. 45 (2) , 82-93
Study of the radiofrequency‐induced heating inside the human head with dental implants at 7 T
Conductive dental implants are commonly used in restorative therapy to replace missing teeth in patients. Ensuring the radiofrequency (RF) safety of these patients is crucial when performing 7 T magnetic resonance scans of their heads. This study aimed to investigate RF‐induced heating inside the human head with dental implants at 7 T. Dental implants and their attachments were fabricated and integrated into an anatomical head model, creating different measurement configurations (MCs). Numerical simulations were conducted using a 7 T transmit coil loaded with the anatomical head model, both with and without dental implants. The maximum temperatures inside the head for various MCs were computed using the maximum permissible input powers (MPIPs) obtained without dental implants and compared with published limits. Additionally, the MPIPs with dental implants were calculated for scenarios where the temperature limits were exceeded. The maximum temperatures observed inside the head ranged from 38.4°C to 39.6°C. The MPIPs in the presence of dental implants were 81.9%–97.3% of the MPIPs in the absence of dental implants for scenarios that exceeded the regulatory limit. RF‐induced heating effect of the dental implants was not significant. The safe scanning condition in terms of RF exposure was achievable for patients with dental implants. For patients with conductive dental implants of unknown configuration, it is recommended to reduce the input power by 18.1% of MPIP without dental implants to ensure RF safety.
- 20 October 2023
- Published by Wiley in Bioelectromagnetics
- Vol. 45 (2) , 82-93
Study of the radiofrequency‐induced heating inside the human head with dental implants at 7 T
Conductive dental implants are commonly used in restorative therapy to replace missing teeth in patients. Ensuring the radiofrequency (RF) safety of these patients is crucial when performing 7 T magnetic resonance scans of their heads. This study aimed to investigate RF‐induced heating inside the human head with dental implants at 7 T. Dental implants and their attachments were fabricated and integrated into an anatomical head model, creating different measurement configurations (MCs). Numerical simulations were conducted using a 7 T transmit coil loaded with the anatomical head model, both with and without dental implants. The maximum temperatures inside the head for various MCs were computed using the maximum permissible input powers (MPIPs) obtained without dental implants and compared with published limits. Additionally, the MPIPs with dental implants were calculated for scenarios where the temperature limits were exceeded. The maximum temperatures observed inside the head ranged from 38.4°C to 39.6°C. The MPIPs in the presence of dental implants were 81.9%–97.3% of the MPIPs in the absence of dental implants for scenarios that exceeded the regulatory limit. RF‐induced heating effect of the dental implants was not significant. The safe scanning condition in terms of RF exposure was achievable for patients with dental implants. For patients with conductive dental implants of unknown configuration, it is recommended to reduce the input power by 18.1% of MPIP without dental implants to ensure RF safety.
- Open Access
- 21 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 15 (5) , 1-6
A Novel Design Method of Uniformity Energy Distribution Lens for Miniscopes
Objective: Calcium imaging is an essential tool for obtaining neuroactivities to understand the complex function of the brain. The one-photon miniscope, the most widely used endoscope in neuroscience, is employed to record neuronal calcium activities in vivo. However, the current half ball lens overlooks the energy distribution in the brain field, resulting in non-uniform fluorescence imaging and the omission of important signals, leading to misunderstanding in brain science. The main flaw in the existing lens is the lack of controlled energy distribution, where the center fluorescence is much stronger than the edge area, causing the fluorescence noisy background to overlap with numerous neuron signals. To address this issue, we propose a novel approach to simplify the optical path by setting a medial target. By combining the Ray Mapping Method and Energy Feedback Method, we design and optimize the lens based on the energy mapping mesh. Simulation results demonstrate a 2.1-fold enhancement in energy distribution uniformity in the brain field compared to the original half-ball lens, with edge neurons receiving 6.95 times more energy. This novel design is theoretically proved to be an innovative improvement of the one-photon miniscope method, being a potential breakthrough of this mainstream method lasting more than ten years.
- 21 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 15 (5) , 1-6
Open AccessA Novel Design Method of Uniformity Energy Distribution Lens for Miniscopes
Objective: Calcium imaging is an essential tool for obtaining neuroactivities to understand the complex function of the brain. The one-photon miniscope, the most widely used endoscope in neuroscience, is employed to record neuronal calcium activities in vivo. However, the current half ball lens overlooks the energy distribution in the brain field, resulting in non-uniform fluorescence imaging and the omission of important signals, leading to misunderstanding in brain science. The main flaw in the existing lens is the lack of controlled energy distribution, where the center fluorescence is much stronger than the edge area, causing the fluorescence noisy background to overlap with numerous neuron signals. To address this issue, we propose a novel approach to simplify the optical path by setting a medial target. By combining the Ray Mapping Method and Energy Feedback Method, we design and optimize the lens based on the energy mapping mesh. Simulation results demonstrate a 2.1-fold enhancement in energy distribution uniformity in the brain field compared to the original half-ball lens, with edge neurons receiving 6.95 times more energy. This novel design is theoretically proved to be an innovative improvement of the one-photon miniscope method, being a potential breakthrough of this mainstream method lasting more than ten years.