Abstract
A gamma-ray imaging system has been developed for acquiring stereo images of the distribution of radiopharmaceuticals in breast tissue. The system consists of a small field-of-view gamma-ray camera mounted to a stereotactic biopsy table. The camera is mounted on a rotational arm such that it can be used to image the breast from two 15deg stereo views. These stereo images can be used to determine the three dimensional spatial location of a region of focal uptake. Once the location of this region is determined, this information can be used as a guide for stereotactic core needle biopsy. The accuracy that the spatial location of a source can be determined was investigated by moving a point source within the field of view. A center-of gravity calculation was used to localize the centroid of the image of the source and this was used to determine the spatial location. Measurements indicate that the source can be localized to within 1 mm. A comparison of the operation of the gamma imaging system and an x-ray imaging system has been done using a dual modality phantom. These measurements indicated that the spatial location of an isolated source can be determined by the gamma imaging system to within approximately the same performance criteria as required for the X-ray system (1 mm). Collimators were tested to determine the spatial resolution in the transverse dimension and the impact of this transverse resolution on the axial resolution was investigated. The performance of this gamma-guided stereotactic biopsy system will be presentedKeywords
This publication has 7 references indexed in Scilit:
- PCI data acquisition card for application in radiation imaging systems2004
- X-ray stereotactic lesion localization in conjunction with dedicated scintimammographyIEEE Transactions on Nuclear Science, 2003
- Small field of view scintimammography gamma camera integrated to a stereotactic core biopsy digital X-ray systemIEEE Transactions on Nuclear Science, 2002
- Optimization of breast imaging procedure with dedicated compact gamma camerasNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- An apparatus for positron emission mammography-guided breast biopsy2002
- Optimization of dedicated scintimammography procedure using detector prototypes and compressible phantomsIEEE Transactions on Nuclear Science, 2001
- Development of an application specific scintimammography detector based on a crystal scintillator array and a PSPMTNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998