Gamma-Guided Stereotactic Breast Biopsy System
A gamma-ray imaging system has been developed for acquiring stereo images of the distribution of radiopharmaceuticals in breast tissue. The system consists of a small field-of-view gamma-ray camera mounted to a stereotactic biopsy table. The camera is mounted on a rotational arm such that it can be used to image the breast from two 15deg stereo views. These stereo images can be used to determine the three dimensional spatial location of a region of focal uptake. Once the location of this region is determined, this information can be used as a guide for stereotactic core needle biopsy. The accuracy that the spatial location of a source can be determined was investigated by moving a point source within the field of view. A center-of gravity calculation was used to localize the centroid of the image of the source and this was used to determine the spatial location. Measurements indicate that the source can be localized to within 1 mm. A comparison of the operation of the gamma imaging system and an x-ray imaging system has been done using a dual modality phantom. These measurements indicated that the spatial location of an isolated source can be determined by the gamma imaging system to within approximately the same performance criteria as required for the X-ray system (1 mm). Collimators were tested to determine the spatial resolution in the transverse dimension and the impact of this transverse resolution on the axial resolution was investigated. The performance of this gamma-guided stereotactic biopsy system will be presented
- 16 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 53 (5) , 2690-2697
Gamma-Guided Stereotactic Breast Biopsy System
A gamma-ray imaging system has been developed for acquiring stereo images of the distribution of radiopharmaceuticals in breast tissue. The system consists of a small field-of-view gamma-ray camera mounted to a stereotactic biopsy table. The camera is mounted on a rotational arm such that it can be used to image the breast from two 15deg stereo views. These stereo images can be used to determine the three dimensional spatial location of a region of focal uptake. Once the location of this region is determined, this information can be used as a guide for stereotactic core needle biopsy. The accuracy that the spatial location of a source can be determined was investigated by moving a point source within the field of view. A center-of gravity calculation was used to localize the centroid of the image of the source and this was used to determine the spatial location. Measurements indicate that the source can be localized to within 1 mm. A comparison of the operation of the gamma imaging system and an x-ray imaging system has been done using a dual modality phantom. These measurements indicated that the spatial location of an isolated source can be determined by the gamma imaging system to within approximately the same performance criteria as required for the X-ray system (1 mm). Collimators were tested to determine the spatial resolution in the transverse dimension and the impact of this transverse resolution on the axial resolution was investigated. The performance of this gamma-guided stereotactic biopsy system will be presented
- 30 November 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4, 2300-2304 Vol.4
Simultaneous /sup 125/I SPECT imaging of small animals with pinhole and parallel collimation
A rotating cylindrical gantry apparatus holding a pair of Hamamatsu R3292 position sensitive photomultiplier tubes (PSPMTs), each of which can include either a parallel-hole collimator or a pinhole collimator, has been used to gather planar images and single photon emission computer tomography (SPECT) data of an entire mouse. In addition, in a number of experiments a magnified view of a specific organ was obtained with pinhole collimation. The scintillators used were pixelated NaI(Tl) or CsI(Tl) with pixels 1/spl times/1/spl times/3 mm and were air coupled to the PSPMTs. The active area of each detector was a circle about 110 mm in diameter. The parallel hole detector had an intrinsic resolution in planar images of 2 mm and the pinhole collimator was used in a magnification which yielded 1 mm spatial resolution. A rigid, lightweight Lexan tube is used to contain a heated mouse bed formed in a semicylindrical shape. Warmed, humidified air as well as gas anesthetic can be introduced and exhausted via the tube. The arrangement facilitates accurate centering and positioning of the SPECT cameras to the animal. The simultaneous acquisition of whole body data and a magnified image of the gut and pancreas within the animal has been applied in a study of /sup 125/I tagged insulin in hyperglycemic and normal mice. In a study of the effectiveness of KI blocking on uptake of iodine in a mouse thyroid, images a phantom of the thyroid and submaxillary glands were of considerable interest.
- 30 November 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4, 2300-2304 Vol.4
Simultaneous /sup 125/I SPECT imaging of small animals with pinhole and parallel collimation
A rotating cylindrical gantry apparatus holding a pair of Hamamatsu R3292 position sensitive photomultiplier tubes (PSPMTs), each of which can include either a parallel-hole collimator or a pinhole collimator, has been used to gather planar images and single photon emission computer tomography (SPECT) data of an entire mouse. In addition, in a number of experiments a magnified view of a specific organ was obtained with pinhole collimation. The scintillators used were pixelated NaI(Tl) or CsI(Tl) with pixels 1/spl times/1/spl times/3 mm and were air coupled to the PSPMTs. The active area of each detector was a circle about 110 mm in diameter. The parallel hole detector had an intrinsic resolution in planar images of 2 mm and the pinhole collimator was used in a magnification which yielded 1 mm spatial resolution. A rigid, lightweight Lexan tube is used to contain a heated mouse bed formed in a semicylindrical shape. Warmed, humidified air as well as gas anesthetic can be introduced and exhausted via the tube. The arrangement facilitates accurate centering and positioning of the SPECT cameras to the animal. The simultaneous acquisition of whole body data and a magnified image of the gut and pancreas within the animal has been applied in a study of /sup 125/I tagged insulin in hyperglycemic and normal mice. In a study of the effectiveness of KI blocking on uptake of iodine in a mouse thyroid, images a phantom of the thyroid and submaxillary glands were of considerable interest.
- 22 March 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1883-1886 vol.3
A large field of view positron emission mammography imager
Dedicated positron emission mammography (PEM) systems provide a potentially high sensitivity, high-resolution, low attenuation and lower cost alternative to whole body PET. We have designed, built, and performed initial evaluation of a large field-of-view PEM system. This system uses two 15 cm /spl times/ 20 cm planar detectors. Each detector has an array of 3 mm /spl times/ 3 mm /spl times/ 10 mm LGSO (90% LSO, 10% GSO) scintillator crystals read out by an 6 /spl times/ 8 array of 25 mm /spl times/ 25 mm position-sensitive photomultipliers. The detectors are mounted on a gantry that is used in conjunction with an X-ray mammography unit such that when the film holder is rotated away the upper detector is above the compression paddle, which is used to compress the breast against the lower PEM detector.
- 22 March 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1883-1886 vol.3
A large field of view positron emission mammography imager
Dedicated positron emission mammography (PEM) systems provide a potentially high sensitivity, high-resolution, low attenuation and lower cost alternative to whole body PET. We have designed, built, and performed initial evaluation of a large field-of-view PEM system. This system uses two 15 cm /spl times/ 20 cm planar detectors. Each detector has an array of 3 mm /spl times/ 3 mm /spl times/ 10 mm LGSO (90% LSO, 10% GSO) scintillator crystals read out by an 6 /spl times/ 8 array of 25 mm /spl times/ 25 mm position-sensitive photomultipliers. The detectors are mounted on a gantry that is used in conjunction with an X-ray mammography unit such that when the film holder is rotated away the upper detector is above the compression paddle, which is used to compress the breast against the lower PEM detector.
- 2 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Investigation of a position sensitive photomultiplier
Results of an investigation of the physical properties of the position-sensitive photomultiplier Hamamatsu R4135 are presented. The purpose of present experiments is to determine which fibres have the best characteristics for use in a scintillating fibre detector system and also to test various photomultiplier tubes to determine their resolution characteristics. Observed performances for fibre identification and position resolutions are reported.
- 2 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Investigation of a position sensitive photomultiplier
Results of an investigation of the physical properties of the position-sensitive photomultiplier Hamamatsu R4135 are presented. The purpose of present experiments is to determine which fibres have the best characteristics for use in a scintillating fibre detector system and also to test various photomultiplier tubes to determine their resolution characteristics. Observed performances for fibre identification and position resolutions are reported.
- 1 June 2001
- Vol. 42 (6) , 960-6
Positron emission mammography-guided breast biopsy.
Positron emission mammography (PEM) is a technique to obtain planar images of the breast for detection of potentially cancerous, radiotracer-avid tumors. To increase the diagnostic accuracy of this method, use of minimally invasive methods (e.g., core biopsy) may be desirable for obtaining tissue samples from lesions detected with PEM. The purpose of this study was to test the capabilities of a novel method for performing PEM-guided stereotactic breast biopsies. The PEM system consisted of 2 square (10 x 10 cm) arrays of discrete scintillator crystals. The detectors were mounted on a stereotactic biopsy table. The stereotactic technique used 2 PEM images acquired at +/-15 degrees and a new trigonometric algorithm. The accuracy and precision of the guidance method was tested by placement of small point sources of (18)F at known locations within the field of view of the imager. The calculated positions of the sources were compared with the known locations. In addition, simulated stereotactic biopsies of a breast phantom consisting of a 10-mm-diameter gelatin sphere containing a concentration of (18)F-FDG consistent with that reported for breast cancer were performed. The simulated lesion was embedded in a 4-cm-thick slab of gelatin containing a commonly reported concentration of FDG, simulating a compressed breast (target-to-background ratio, approximately 8.5:1). An anthropomorphic torso phantom was used to simulate tracer uptake in the organs of a patient 1 h after a 370-MBq injection of FDG. Five trials of the biopsy procedure were performed to assess repeatability. Finally, a method for verifying needle positioning was tested. The positions of the point sources were successfully calculated to within 0.6 mm of their true positions with a mean error of +/-0.4 mm. The biopsy procedures, including the method for verification of needle position, were successful in all 5 trials in acquiring samples from the simulated lesions. The success of this new technique shows its potential for guiding the biopsy of breast lesions optimally detected with PEM.
- 1 June 2001
- Vol. 42 (6) , 960-6
Positron emission mammography-guided breast biopsy.
Positron emission mammography (PEM) is a technique to obtain planar images of the breast for detection of potentially cancerous, radiotracer-avid tumors. To increase the diagnostic accuracy of this method, use of minimally invasive methods (e.g., core biopsy) may be desirable for obtaining tissue samples from lesions detected with PEM. The purpose of this study was to test the capabilities of a novel method for performing PEM-guided stereotactic breast biopsies. The PEM system consisted of 2 square (10 x 10 cm) arrays of discrete scintillator crystals. The detectors were mounted on a stereotactic biopsy table. The stereotactic technique used 2 PEM images acquired at +/-15 degrees and a new trigonometric algorithm. The accuracy and precision of the guidance method was tested by placement of small point sources of (18)F at known locations within the field of view of the imager. The calculated positions of the sources were compared with the known locations. In addition, simulated stereotactic biopsies of a breast phantom consisting of a 10-mm-diameter gelatin sphere containing a concentration of (18)F-FDG consistent with that reported for breast cancer were performed. The simulated lesion was embedded in a 4-cm-thick slab of gelatin containing a commonly reported concentration of FDG, simulating a compressed breast (target-to-background ratio, approximately 8.5:1). An anthropomorphic torso phantom was used to simulate tracer uptake in the organs of a patient 1 h after a 370-MBq injection of FDG. Five trials of the biopsy procedure were performed to assess repeatability. Finally, a method for verifying needle positioning was tested. The positions of the point sources were successfully calculated to within 0.6 mm of their true positions with a mean error of +/-0.4 mm. The biopsy procedures, including the method for verification of needle position, were successful in all 5 trials in acquiring samples from the simulated lesions. The success of this new technique shows its potential for guiding the biopsy of breast lesions optimally detected with PEM.
- 1 September 1998
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 414 (2-3) , 289-298
Economical detectors based on safe liquid scintillators
- 1 September 1998
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 414 (2-3) , 289-298
Economical detectors based on safe liquid scintillators
- 1 June 1997
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 392 (1-3) , 475-478
Single shot dual energy reverse geometry X-radiography
- 1 June 1997
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 392 (1-3) , 475-478
Single shot dual energy reverse geometry X-radiography
- 1 August 1994
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 41 (4) , 746-751
Low dose rate evaluations of long plastic scintillator plates and Bicron G2-doped wavelength shifting fibers
- 1 August 1994
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 41 (4) , 746-751
Low dose rate evaluations of long plastic scintillator plates and Bicron G2-doped wavelength shifting fibers
- 1 August 1994
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 41 (4) , 708-712
Optimization of the use of small inexpensive side-window photomultiplier tubes for scintillator readout
- 1 August 1994
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 41 (4) , 708-712
Optimization of the use of small inexpensive side-window photomultiplier tubes for scintillator readout
- 1 August 1993
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 40 (4) , 455-460
Low cross-talk fiber readout of scintillating detectors
- 1 August 1993
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 40 (4) , 455-460
Low cross-talk fiber readout of scintillating detectors