Evaluation of the hyperspectral multicomponent calibration for plastic scintillation dosimetry
Open Access
- 14 June 2026
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (11) , 115005
Abstract
Objective. Accurate and precise dose measurements are critical for the validation of radiotherapy treatments. Plastic scintillation dosimeters (PSDs), when carefully calibrated, offer a solution. This study provides a systematic investigation of different calibration methods for PSDs based on hyperspectral identification of scintillation. Furthermore, performance of these calibration methods is evaluated for a conventional linac and an MR-linac. Approach. For this study, seven calibration types were applied, each considering a different number of physical and optical components, including different combinations. The inclusion of a component was analysed by evaluating the residual, which provided information about the amount of unlabelled signal. The residuals and the measured doses were evaluated for reproducibility, output factors and angular dependence. The error of the dose measurement offers an indication of how effectively the scintillation component is identified. Main results. The addition of calibration components, such as Cherenkov (proximal and distal), fluorescence, and drift correction, resulted in a progressive reduction in the residual. Consequently, a smaller proportion of the signal remained unlabelled. The absolute dose differences across the measurements also decreased with the addition of components. The inclusion of the Cherenkov component yielded the most substantial improvement in accuracy. For example, the dose discrepancy decreased from more than 70% to less than 1% for large field sizes on the MR-linac. Significance. These findings demonstrate that the hyperspectral calibration significantly improves PSD accuracy and precision, particularly with the inclusion of the Cherenkov component. This improvement is observed consistently across different setups and on both the conventional linac and the MR-linac.Keywords
Funding Information
- NWO (Project no. 20827 (ART-PIVOT))
This publication has 34 references indexed in Scilit:
- AAPM task group report 351: Protocol for clinical reference dosimetry in external beam MR‐guided radiotherapyMedical Physics, 2025
- Field output correction factors using a scintillation detectorMedical Physics, 2025
- Radioluminescence-based fibre-optic dosimeters in radiotherapy: a reviewRadiation Measurements, 2024
- Quantifying uncertainties associated with reference dosimetry in an MR‐LinacJournal of Applied Clinical Medical Physics, 2023
- Time-resolved plastic scintillator dosimetry in MR linear accelerators without image distortionRadiation Measurements, 2022
- Pre‐clinical and clinical evaluation of the HYPERSCINT plastic scintillation dosimetry research platform for in vivo dosimetry during radiotherapyJournal of Applied Clinical Medical Physics, 2022
- Commissioning of a 1.5T Elekta Unity MR‐linac: A single institution experienceJournal of Applied Clinical Medical Physics, 2020
- Characterization of spectral and intensity changes with measurement geometry in various light guides used in scintillation dosimetryMedical Physics, 2018
- Effect of magnetic field strength on plastic scintillation detector responseRadiation Measurements, 2018
- Plastic scintillation dosimetry and its application to radiotherapyRadiation Measurements, 2006