    Evaluation of the hyperspectral multicomponent calibration for plastic scintillation dosimetry

    by Laurie J M de Vries, Pim T S Borman, Tom Bosma, Thomas Foppen, Simon J Woodings, Benjamin Côté, Simon Lambert-Girard, François Therriault-Proulx, Louis Archambault, Martin F Fast

    Objective. Accurate and precise dose measurements are critical for the validation of radiotherapy treatments. Plastic scintillation dosimeters (PSDs), when carefully calibrated, offer a solution. This study provides a systematic investigation of different calibration methods for PSDs based on hyperspectral identification of scintillation. Furthermore, performance of these calibration methods is evaluated for a conventional linac and an MR-linac. Approach. For this study, seven calibration types were applied, each considering a different number of physical and optical components, including different combinations. The inclusion of a component was analysed by evaluating the residual, which provided information about the amount of unlabelled signal. The residuals and the measured doses were evaluated for reproducibility, output factors and angular dependence. The error of the dose measurement offers an indication of how effectively the scintillation component is identified. Main results. The addition of calibration components, such as Cherenkov (proximal and distal), fluorescence, and drift correction, resulted in a progressive reduction in the residual. Consequently, a smaller proportion of the signal remained unlabelled. The absolute dose differences across the measurements also decreased with the addition of components. The inclusion of the Cherenkov component yielded the most substantial improvement in accuracy. For example, the dose discrepancy decreased from more than 70% to less than 1% for large field sizes on the MR-linac. Significance. These findings demonstrate that the hyperspectral calibration significantly improves PSD accuracy and precision, particularly with the inclusion of the Cherenkov component. This improvement is observed consistently across different setups and on both the conventional linac and the MR-linac.

  • Open Access

    Development and validation of commissioning tests for volumetric modulated arc therapy on the 1.5T MR-linac

    by C.R. Hoek, D.E. Hyer, T.A. Foppen, P.T.S. Borman, P.L. Woodhead, L.E. van Heerden, B.W. Raaymakers, M.F. Fast, S.L. Hackett

  • Open Access

    The first experimental implementation of real-time dose-guided MLC tracking using an MRI-linac

    by Emily A. Hewson, Pim T.S. Borman, Bas W. Raaymakers, Paul J. Keall, Martin F. Fast

  • Open Access

    First experimental demonstration of magnetic resonance-guided multileaf collimator tracking for (ultra-)hypofractionated prostate radiotherapy

    by Prescilla Uijtewaal, Pim T.S. Borman, Peter L. Woodhead, Hans C.J. de Boer, Bas W. Raaymakers, Martin F. Fast


  • Open Access

    Enabling in vivo comparisons of different four-dimensional magnetic resonance imaging sequences for radiotherapy guidance using visual biofeedback

    by Katrinus Keijnemans, Tim Schakel, Bastien Lecoeur, Pim T.S. Borman, William A. Hall, Bas W. Raaymakers, Andreas Wetscherek, Eric S. Paulson, Martin F. Fast

  • Open Access

    A coil-channel multiplexer for high-density receive arrays compatible with the MR-linac

    by Tom Bosma, Jan G M Kok, Pim T S Borman, Cornelis A T van Den Berg, Martin F Fast

    Objective. We present a prototype add-on multiplexer for retro-fitting high-channel count receive coils onto systems with analog readout chains, such as the MR-linac. This particular system is currently equipped with two coil elements, containing only four channels each. Approach. We developed a 4:1 multiplexer board based on time-division. CMOS-based single-pole double-throw switches were used to accommodate for fast switching and adequate encoding bandwidths. Coil-channel images were separated after reconstruction by solving a system of equations based on the square-wave modulation imposed by the multiplexer. The prototype was tested at a 1.5 T scanner on an image-quality phantom and a slice of bovine muscle using four coil channels from a previously characterized 16-channel anterior coil prototype. Main results. The image data received through multiplexing could be reliably divided into separate coil-channel images, preserving the coil sensitivity maps. Leakage between channels remained below −30 dB. In each coil channel the signal-to-noise ratio was penalized by a factor of two compared to direct digitization due to the inflicted data compression. Furthermore, it was shown that the g-factor for parallel imaging remained largely unaffected by multiplexing. Imaging speedup is expected with this multiplexer, since a fourfold channel-count increase typically yields g-factor improvements that are superior to the signal-quality reduction. Significance. A 4:1 coil-channel add-on multiplexer was developed and its functionality demonstrated in the MR readout chain at 1.5 T. We expect that this solution will enable significant imaging speedup for clinical MR systems that suffer from compatibility with a limited number of channels for the receive coil array.


  • Open Access

    Demonstration of motion-compensated volumetric modulated arc radiotherapy on an MR-linac

    by Pim T.S. Borman, Prescilla Uijtewaal, Jeffrey Snyder, Bryan Allen, Caiden K. Atienza, Peter Woodhead, Daniel E. Hyer, Bas W. Raaymakers, Martin F. Fast


  • Open Access

    Characterization of an MR‐compatible motion platform for quality assurance of motion‐compensated treatments on the 1.5 T MR‐linac

    by Stijn Oolbekkink, Pim T. S. Borman, Jochem W. H. Wolthaus, Bram van Asselen, Astrid L. H. M. W. van Lier, Stephanie Dunn, Grant R. Koenig, Nick Hartman, Niusha Kheirkhah, Bas W. Raaymakers, et al.

    Background: Novel motion‐compensated treatment techniques on the MR‐linac can address adverse intra‐fraction motion effects. These techniques involve beam gating or intra‐fraction adaptations of the treatment plan based on real‐time magnetic resonance imaging (MRI) performed during treatment. For quality assurance (QA) of these workflows, a multi‐purpose motion platform is desirable. This platform should accommodate various phantoms, enabling multiple QA workflows. Purpose: This study aims to evaluate the new IBA QUASAR Motion MR Platform for use in the 1.5 T MR‐linac. Methods: The motion platform was assessed for several magnetic resonance (MR) characteristics, including spurious noise generation and B0&B1 homogeneity. In addition, the motion platform's motion accuracy and beam attenuation were assessed. An application was shown with a ScandiDos Delta4 Phantom+ MR demonstrating patient‐specific plan QA of gated treatments using time‐resolved dosimetry that includes motion based on a patient's respiratory motion trace. Results: All MR characterization measurements were within the set tolerances for MRI QA. The motion platform motion accuracy showed excellent agreement with the reference, with a standard deviation of the amplitude of 0.01 mm (20 kg load) for the motor's self‐estimated positions and 0.22 mm (no load) for the images acquired with the electronic portal imager. Beam attenuation was found to be 11.8%. The combination of the motion platform and Delta4 demonstrated motion‐included dosimetry at high temporal and spatial resolutions. Motion influenced the measured dose in non‐gated treatments by up to −20.1%, while gated deliveries showed differences of up to −1.7% for selected diodes. Conclusion: The motion platform was found to be usable in a 1.5 T magnetic field, and for all MR characterization experiments, no influence from the motion platform was observed. This motion platform enables to perform motion‐included QA, with a measurement device of choice.


  • First Patient Study with Visual Biofeedback for Gating Delivery Efficiency Improvements on a 1.5 T MR-Linac

    by F.P.D. van Gameren, P.T.S. Borman, L.T.C. Meijers, R.H.A. Rutgers, J.M. Westerhoff, A.L.H.M.W. van Lier, M.P.W. Intven, B.W. Raaymakers, M.F. Fast


  • Open Access

    Effectiveness of visual biofeedback–guided respiratory‐correlated 4D‐MRI for radiotherapy guidance on the MR‐linac

    by Katrinus Keijnemans, Pim T. S. Borman, Bas W. Raaymakers, Martin F. Fast

    Purpose: Respiratory‐correlated 4D‐MRI may provide motion characteristics for radiotherapy but is susceptible to irregular breathing. This study investigated the effectiveness of visual biofeedback (VBF) guidance for breathing regularization during 4D‐MRI acquisitions on an MR‐linac.Methods: A simultaneous multislice‐accelerated 4D‐MRI sequence was interleaved with a one‐dimensional respiratory navigator (1D‐RNAV) in 10 healthy volunteers on a 1.5T Unity MR‐linac (Elekta AB, Stockholm, Sweden). Volunteer‐specific breathing amplitudes and periods were derived from the 1D‐RNAV signal obtained during unguided 4D‐MRI acquisitions. These were used for the guidance waveform, while the 1D‐RNAV positions were overlayed as VBF. VBF effectiveness was quantified by calculating the change in coefficient of variation () for the breathing amplitude and period, the position SD of end‐exhale, end‐inhale and midposition locations, and the agreement between the 1D‐RNAV signals and guidance waveforms. The 4D‐MRI quality was assessed by quantifying amounts of missing data.Results: VBF had an average latency of 520 ± 2 ms. VBF reduced median breathing variations by 18% to 35% (amplitude) and 29% to 57% (period). Median position SD reductions ranged from −3% to 35% (end‐exhale), 29% to 38% (end‐inhale), and 25% to 37% (midposition). Average differences between guidance waveforms and 1D‐RNAV signals were 0.0 s (period) and +1.7 mm (amplitude). VBF also decreased the median amount of missing data by 11% and 29%.Conclusion: A VBF system was successfully implemented, and all volunteers were able to adapt to the guidance waveform. VBF during 4D‐MRI acquisitions drastically reduced breathing variability but had limited effect on missing data in respiratory‐correlated 4D‐MRI.