Pim T. S. Borman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pim T. S. Borman has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Martin F. Fast
Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
12 shared publications Bas W. Raaymakers
Department of Radiotherapy, University Medical Center Utrecht, the Netherlands
4 shared publicationsB W Raaymakers
University Medical Center Utrecht
3 shared publicationsBas W Raaymakers
Department of Radiotherapy, Universitair Medisch Centrum Utrecht, HP Q.00.118, Heidelberglaan 100, 3584 CX Utrecht, THE NETHERLANDS, Utrecht, NETHERLANDS
3 shared publications- Bas W. Raaymakers
Department of Radiotherapy, University Medical Center Utrecht, Netherlands
3 shared publications - Katrinus Keijnemans
Department of Radiotherapy University Medical Center Utrecht Utrecht The Netherlands
3 shared publications
Latest Publications
- Open Access
- 14 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (11) , 115005
Evaluation of the hyperspectral multicomponent calibration for plastic scintillation dosimetry
Objective. Accurate and precise dose measurements are critical for the validation of radiotherapy treatments. Plastic scintillation dosimeters (PSDs), when carefully calibrated, offer a solution. This study provides a systematic investigation of different calibration methods for PSDs based on hyperspectral identification of scintillation. Furthermore, performance of these calibration methods is evaluated for a conventional linac and an MR-linac. Approach. For this study, seven calibration types were applied, each considering a different number of physical and optical components, including different combinations. The inclusion of a component was analysed by evaluating the residual, which provided information about the amount of unlabelled signal. The residuals and the measured doses were evaluated for reproducibility, output factors and angular dependence. The error of the dose measurement offers an indication of how effectively the scintillation component is identified. Main results. The addition of calibration components, such as Cherenkov (proximal and distal), fluorescence, and drift correction, resulted in a progressive reduction in the residual. Consequently, a smaller proportion of the signal remained unlabelled. The absolute dose differences across the measurements also decreased with the addition of components. The inclusion of the Cherenkov component yielded the most substantial improvement in accuracy. For example, the dose discrepancy decreased from more than 70% to less than 1% for large field sizes on the MR-linac. Significance. These findings demonstrate that the hyperspectral calibration significantly improves PSD accuracy and precision, particularly with the inclusion of the Cherenkov component. This improvement is observed consistently across different setups and on both the conventional linac and the MR-linac.
- 14 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (11) , 115005
Open AccessEvaluation of the hyperspectral multicomponent calibration for plastic scintillation dosimetry
Objective. Accurate and precise dose measurements are critical for the validation of radiotherapy treatments. Plastic scintillation dosimeters (PSDs), when carefully calibrated, offer a solution. This study provides a systematic investigation of different calibration methods for PSDs based on hyperspectral identification of scintillation. Furthermore, performance of these calibration methods is evaluated for a conventional linac and an MR-linac. Approach. For this study, seven calibration types were applied, each considering a different number of physical and optical components, including different combinations. The inclusion of a component was analysed by evaluating the residual, which provided information about the amount of unlabelled signal. The residuals and the measured doses were evaluated for reproducibility, output factors and angular dependence. The error of the dose measurement offers an indication of how effectively the scintillation component is identified. Main results. The addition of calibration components, such as Cherenkov (proximal and distal), fluorescence, and drift correction, resulted in a progressive reduction in the residual. Consequently, a smaller proportion of the signal remained unlabelled. The absolute dose differences across the measurements also decreased with the addition of components. The inclusion of the Cherenkov component yielded the most substantial improvement in accuracy. For example, the dose discrepancy decreased from more than 70% to less than 1% for large field sizes on the MR-linac. Significance. These findings demonstrate that the hyperspectral calibration significantly improves PSD accuracy and precision, particularly with the inclusion of the Cherenkov component. This improvement is observed consistently across different setups and on both the conventional linac and the MR-linac.
- Open Access
- 14 May 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 221, 111568
Development and validation of commissioning tests for volumetric modulated arc therapy on the 1.5T MR-linac
- 14 May 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 221, 111568
Open AccessDevelopment and validation of commissioning tests for volumetric modulated arc therapy on the 1.5T MR-linac
- Open Access
- 12 April 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 219, 111536
The first experimental implementation of real-time dose-guided MLC tracking using an MRI-linac
- 12 April 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 219, 111536
Open AccessThe first experimental implementation of real-time dose-guided MLC tracking using an MRI-linac
- Open Access
- 13 September 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 36
First experimental demonstration of magnetic resonance-guided multileaf collimator tracking for (ultra-)hypofractionated prostate radiotherapy
- 13 September 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 36
Open AccessFirst experimental demonstration of magnetic resonance-guided multileaf collimator tracking for (ultra-)hypofractionated prostate radiotherapy
- Open Access
- 5 August 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 35, 100815
Enabling in vivo comparisons of different four-dimensional magnetic resonance imaging sequences for radiotherapy guidance using visual biofeedback
- 5 August 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 35, 100815
Open AccessEnabling in vivo comparisons of different four-dimensional magnetic resonance imaging sequences for radiotherapy guidance using visual biofeedback
- Open Access
- 14 May 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (10) , 105016
A coil-channel multiplexer for high-density receive arrays compatible with the MR-linac
Objective. We present a prototype add-on multiplexer for retro-fitting high-channel count receive coils onto systems with analog readout chains, such as the MR-linac. This particular system is currently equipped with two coil elements, containing only four channels each. Approach. We developed a 4:1 multiplexer board based on time-division. CMOS-based single-pole double-throw switches were used to accommodate for fast switching and adequate encoding bandwidths. Coil-channel images were separated after reconstruction by solving a system of equations based on the square-wave modulation imposed by the multiplexer. The prototype was tested at a 1.5 T scanner on an image-quality phantom and a slice of bovine muscle using four coil channels from a previously characterized 16-channel anterior coil prototype. Main results. The image data received through multiplexing could be reliably divided into separate coil-channel images, preserving the coil sensitivity maps. Leakage between channels remained below −30 dB. In each coil channel the signal-to-noise ratio was penalized by a factor of two compared to direct digitization due to the inflicted data compression. Furthermore, it was shown that the g-factor for parallel imaging remained largely unaffected by multiplexing. Imaging speedup is expected with this multiplexer, since a fourfold channel-count increase typically yields g-factor improvements that are superior to the signal-quality reduction. Significance. A 4:1 coil-channel add-on multiplexer was developed and its functionality demonstrated in the MR readout chain at 1.5 T. We expect that this solution will enable significant imaging speedup for clinical MR systems that suffer from compatibility with a limited number of channels for the receive coil array.
- 14 May 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (10) , 105016
Open AccessA coil-channel multiplexer for high-density receive arrays compatible with the MR-linac
Objective. We present a prototype add-on multiplexer for retro-fitting high-channel count receive coils onto systems with analog readout chains, such as the MR-linac. This particular system is currently equipped with two coil elements, containing only four channels each. Approach. We developed a 4:1 multiplexer board based on time-division. CMOS-based single-pole double-throw switches were used to accommodate for fast switching and adequate encoding bandwidths. Coil-channel images were separated after reconstruction by solving a system of equations based on the square-wave modulation imposed by the multiplexer. The prototype was tested at a 1.5 T scanner on an image-quality phantom and a slice of bovine muscle using four coil channels from a previously characterized 16-channel anterior coil prototype. Main results. The image data received through multiplexing could be reliably divided into separate coil-channel images, preserving the coil sensitivity maps. Leakage between channels remained below −30 dB. In each coil channel the signal-to-noise ratio was penalized by a factor of two compared to direct digitization due to the inflicted data compression. Furthermore, it was shown that the g-factor for parallel imaging remained largely unaffected by multiplexing. Imaging speedup is expected with this multiplexer, since a fourfold channel-count increase typically yields g-factor improvements that are superior to the signal-quality reduction. Significance. A 4:1 coil-channel add-on multiplexer was developed and its functionality demonstrated in the MR readout chain at 1.5 T. We expect that this solution will enable significant imaging speedup for clinical MR systems that suffer from compatibility with a limited number of channels for the receive coil array.
- Open Access
- 15 February 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 33, 100729
Demonstration of motion-compensated volumetric modulated arc radiotherapy on an MR-linac
- 15 February 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 33, 100729
Open AccessDemonstration of motion-compensated volumetric modulated arc radiotherapy on an MR-linac
- Open Access
- 31 January 2025
- Published by Wiley in Medical Physics
- Vol. 52 (5) , 3391-3397
Characterization of an MR‐compatible motion platform for quality assurance of motion‐compensated treatments on the 1.5 T MR‐linac
Background: Novel motion‐compensated treatment techniques on the MR‐linac can address adverse intra‐fraction motion effects. These techniques involve beam gating or intra‐fraction adaptations of the treatment plan based on real‐time magnetic resonance imaging (MRI) performed during treatment. For quality assurance (QA) of these workflows, a multi‐purpose motion platform is desirable. This platform should accommodate various phantoms, enabling multiple QA workflows. Purpose: This study aims to evaluate the new IBA QUASAR Motion MR Platform for use in the 1.5 T MR‐linac. Methods: The motion platform was assessed for several magnetic resonance (MR) characteristics, including spurious noise generation and B0&B1 homogeneity. In addition, the motion platform's motion accuracy and beam attenuation were assessed. An application was shown with a ScandiDos Delta4 Phantom+ MR demonstrating patient‐specific plan QA of gated treatments using time‐resolved dosimetry that includes motion based on a patient's respiratory motion trace. Results: All MR characterization measurements were within the set tolerances for MRI QA. The motion platform motion accuracy showed excellent agreement with the reference, with a standard deviation of the amplitude of 0.01 mm (20 kg load) for the motor's self‐estimated positions and 0.22 mm (no load) for the images acquired with the electronic portal imager. Beam attenuation was found to be 11.8%. The combination of the motion platform and Delta4 demonstrated motion‐included dosimetry at high temporal and spatial resolutions. Motion influenced the measured dose in non‐gated treatments by up to −20.1%, while gated deliveries showed differences of up to −1.7% for selected diodes. Conclusion: The motion platform was found to be usable in a 1.5 T magnetic field, and for all MR characterization experiments, no influence from the motion platform was observed. This motion platform enables to perform motion‐included QA, with a measurement device of choice.
- 31 January 2025
- Published by Wiley in Medical Physics
- Vol. 52 (5) , 3391-3397
Open AccessCharacterization of an MR‐compatible motion platform for quality assurance of motion‐compensated treatments on the 1.5 T MR‐linac
Background: Novel motion‐compensated treatment techniques on the MR‐linac can address adverse intra‐fraction motion effects. These techniques involve beam gating or intra‐fraction adaptations of the treatment plan based on real‐time magnetic resonance imaging (MRI) performed during treatment. For quality assurance (QA) of these workflows, a multi‐purpose motion platform is desirable. This platform should accommodate various phantoms, enabling multiple QA workflows. Purpose: This study aims to evaluate the new IBA QUASAR Motion MR Platform for use in the 1.5 T MR‐linac. Methods: The motion platform was assessed for several magnetic resonance (MR) characteristics, including spurious noise generation and B0&B1 homogeneity. In addition, the motion platform's motion accuracy and beam attenuation were assessed. An application was shown with a ScandiDos Delta4 Phantom+ MR demonstrating patient‐specific plan QA of gated treatments using time‐resolved dosimetry that includes motion based on a patient's respiratory motion trace. Results: All MR characterization measurements were within the set tolerances for MRI QA. The motion platform motion accuracy showed excellent agreement with the reference, with a standard deviation of the amplitude of 0.01 mm (20 kg load) for the motor's self‐estimated positions and 0.22 mm (no load) for the images acquired with the electronic portal imager. Beam attenuation was found to be 11.8%. The combination of the motion platform and Delta4 demonstrated motion‐included dosimetry at high temporal and spatial resolutions. Motion influenced the measured dose in non‐gated treatments by up to −20.1%, while gated deliveries showed differences of up to −1.7% for selected diodes. Conclusion: The motion platform was found to be usable in a 1.5 T magnetic field, and for all MR characterization experiments, no influence from the motion platform was observed. This motion platform enables to perform motion‐included QA, with a measurement device of choice.
- 27 September 2024
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 120 (2) , S109
First Patient Study with Visual Biofeedback for Gating Delivery Efficiency Improvements on a 1.5 T MR-Linac
- 27 September 2024
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 120 (2) , S109
First Patient Study with Visual Biofeedback for Gating Delivery Efficiency Improvements on a 1.5 T MR-Linac
- Open Access
- 6 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (1) , 297-311
Effectiveness of visual biofeedback–guided respiratory‐correlated 4D‐MRI for radiotherapy guidance on the MR‐linac
Purpose: Respiratory‐correlated 4D‐MRI may provide motion characteristics for radiotherapy but is susceptible to irregular breathing. This study investigated the effectiveness of visual biofeedback (VBF) guidance for breathing regularization during 4D‐MRI acquisitions on an MR‐linac.Methods: A simultaneous multislice‐accelerated 4D‐MRI sequence was interleaved with a one‐dimensional respiratory navigator (1D‐RNAV) in 10 healthy volunteers on a 1.5T Unity MR‐linac (Elekta AB, Stockholm, Sweden). Volunteer‐specific breathing amplitudes and periods were derived from the 1D‐RNAV signal obtained during unguided 4D‐MRI acquisitions. These were used for the guidance waveform, while the 1D‐RNAV positions were overlayed as VBF. VBF effectiveness was quantified by calculating the change in coefficient of variation () for the breathing amplitude and period, the position SD of end‐exhale, end‐inhale and midposition locations, and the agreement between the 1D‐RNAV signals and guidance waveforms. The 4D‐MRI quality was assessed by quantifying amounts of missing data.Results: VBF had an average latency of 520 ± 2 ms. VBF reduced median breathing variations by 18% to 35% (amplitude) and 29% to 57% (period). Median position SD reductions ranged from −3% to 35% (end‐exhale), 29% to 38% (end‐inhale), and 25% to 37% (midposition). Average differences between guidance waveforms and 1D‐RNAV signals were 0.0 s (period) and +1.7 mm (amplitude). VBF also decreased the median amount of missing data by 11% and 29%.Conclusion: A VBF system was successfully implemented, and all volunteers were able to adapt to the guidance waveform. VBF during 4D‐MRI acquisitions drastically reduced breathing variability but had limited effect on missing data in respiratory‐correlated 4D‐MRI.
- 6 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (1) , 297-311
Open AccessEffectiveness of visual biofeedback–guided respiratory‐correlated 4D‐MRI for radiotherapy guidance on the MR‐linac
Purpose: Respiratory‐correlated 4D‐MRI may provide motion characteristics for radiotherapy but is susceptible to irregular breathing. This study investigated the effectiveness of visual biofeedback (VBF) guidance for breathing regularization during 4D‐MRI acquisitions on an MR‐linac.Methods: A simultaneous multislice‐accelerated 4D‐MRI sequence was interleaved with a one‐dimensional respiratory navigator (1D‐RNAV) in 10 healthy volunteers on a 1.5T Unity MR‐linac (Elekta AB, Stockholm, Sweden). Volunteer‐specific breathing amplitudes and periods were derived from the 1D‐RNAV signal obtained during unguided 4D‐MRI acquisitions. These were used for the guidance waveform, while the 1D‐RNAV positions were overlayed as VBF. VBF effectiveness was quantified by calculating the change in coefficient of variation () for the breathing amplitude and period, the position SD of end‐exhale, end‐inhale and midposition locations, and the agreement between the 1D‐RNAV signals and guidance waveforms. The 4D‐MRI quality was assessed by quantifying amounts of missing data.Results: VBF had an average latency of 520 ± 2 ms. VBF reduced median breathing variations by 18% to 35% (amplitude) and 29% to 57% (period). Median position SD reductions ranged from −3% to 35% (end‐exhale), 29% to 38% (end‐inhale), and 25% to 37% (midposition). Average differences between guidance waveforms and 1D‐RNAV signals were 0.0 s (period) and +1.7 mm (amplitude). VBF also decreased the median amount of missing data by 11% and 29%.Conclusion: A VBF system was successfully implemented, and all volunteers were able to adapt to the guidance waveform. VBF during 4D‐MRI acquisitions drastically reduced breathing variability but had limited effect on missing data in respiratory‐correlated 4D‐MRI.