Implant Design Influences Tibial Post Wear Damage in Posterior-stabilized Knees
Authors:
- Mark M. DolanMDMark M. Dolan
- Natalie H. KellyNKNatalie H. Kelly
- Joseph T. NguyenJNJoseph T. Nguyen
- Timothy M. WrightTWTimothy M. Wright
- Steven B. HaasSHSteven B. Haas
- 1 January 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (1) , 160-167
Abstract
Uestions/purposes We used observations made on retrieved implant components from three contemporary posterior-stabilized knee designs to examine how differences in tibial post design affected wear damage on the post. Methods We examined 113 retrieved Zimmer NexGen®, 103 Exactech Optetrak®, and 58 Smith and Nephew Genesis® II posterior-stabilized inserts using a subjective scale to grade post damage. Results All 274 inserts demonstrated wear damage. Total wear scores and scores for wear damage on the anterior post differed among designs: Optetrak® 20 ± 4 and 5 ± 1, NexGen® 13 ± 4 and 3 ± 1, and Genesis® II 8 ± 3 and 1 ± 1, respectively. The Optetrak® had predominantly anterior wear damage, the NexGen® had more global wear damage, and the Genesis® II had predominantly posterior wear damage. Tibial post wear damage and anterior post wear damage were primarily determined by implant design and to a lesser extent by length of implantation and revision diagnosis. Conclusions Although tibial post wear damage is multifactorial, the primary determinant of wear damage, and specifically anterior wear damage, is implant design. Clinical Relevance The constraint provided by the posterior-stabilized post-cam contact in modern knee arthroplasties is reflected in the wear damage patterns that occur during in vivo use. Unintended constraint such as anterior impingement should be addressed through design modifications for future posterior-stabilized knee arthroplasties....Keywords
This publication has 24 references indexed in Scilit:
- Tibial Post Wear in Posterior-stabilized Knee Replacements is Design-dependentClinical Orthopaedics and Related Research, 2008
- Evaluation of impingement of the anterior tibial post during gait in a posteriorly-stabilised total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2008
- In vivo anterior tibial post contact after posterior stabilizing total knee arthroplastyJournal of Orthopaedic Research, 2007
- Stress analysis of the anterior tibial post in posterior stabilized knee prosthesesJournal of Orthopaedic Research, 2007
- Anterior tibial post impingement in a posterior stabilized total knee arthroplastyJournal of Orthopaedic Research, 2005
- The influence of design, materials and kinematics on the in vitro wear of total knee replacementsJournal of Biomechanics, 2005
- Wear, Debris, and Biologic Activity of Cross-linked Polyethylene in the KneeClinical Orthopaedics and Related Research, 2004
- J‐integral fracture toughness and tearing modulus measurement of radiation cross‐linked UHMWPEJournal of Orthopaedic Research, 2002
- Gamma irradiation alters fatigue‐crack behavior and fracture toughness in 1900H and GUR 1050 UHMWPEJournal of Biomedical Materials Research, 2002
- Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prosthesesJournal of Biomedical Materials Research, 1983