Assessing the validity of pressure-measuring insoles in quantifying gait variables
Open Access
- 12 January 2018
- journal article
- research article
- Published by SAGE Publications in Journal of Rehabilitation and Assistive Technologies Engineering
- Vol. 5
Abstract
Introduction: Pressure-measuring insoles can provide a portable alternative to existing gait analysis tools. However, there is disagreement among researchers on their accuracy and the appropriate calibration methods. The purposes of this study were to (1) determine the validity of pressure-measuring insoles for calculating stance time and support-phase impulse during walking using two calibration procedures, and (2) examine the effect of insole size on the results. Methods: Data were collected from 39 participants (23.5 ± 3.24 yrs, 66.7 ± 17.5 kg, 1.64 ± 0.09 m), each wearing appropriately sized insoles as they walked over two consecutive force platforms. Two calibration methods were evaluated: (1) manufacturer’s recommendation, and (2) a participant weight-based approach. Qualitative and quantitative evaluations were conducted. Results: The results indicated that the insoles measured longer stance times than the force platform (differences are less than 10%). Both calibration methods resulted in inaccurate impulse values (differences are 30 and 50% for the two calibration methods, respectively). The results showed that when using the first calibration method, impulse values depended on insole size. The second calibration consistently underestimated the impulse. Conclusions: It was concluded that while the insoles provide acceptable qualitative representation of the gait, the two studied calibration methods may lead to a misleading quantitative assessment.Keywords
Funding Information
- University of Nevada, Las Vegas (Faculty Opportunity Award 2220-272-76TP)
This publication has 28 references indexed in Scilit:
- A Wireless Flexible Sensorized Insole for Gait AnalysisSensors, 2014
- Appropriateness of plantar pressure measurement devices: A comparative technical assessmentGait & Posture, 2010
- Comparison between kinematic and ground reaction force techniques for determining gait events during treadmill walking at different walking speedsMedical Engineering & Physics, 2010
- Estimating the complete ground reaction forces with pressure insoles in walkingJournal of Biomechanics, 2008
- Inverse dynamics calculations during gait with restricted ground reaction force information from pressure insolesGait & Posture, 2006
- Accuracy and precision of two in-shoe pressure measurement systemsErgonomics, 2002
- Plantar pressure distribution measurements. Technical background and clinical applicationsFoot and Ankle Surgery, 1997
- Observations on the F-Scan in-shoe pressure measuring systemClinical Biomechanics, 1996
- In-shoe plantar pressure measurement: a reviewThe Foot, 1992
- Cushioning properties of footwear during walking: accelerometer and force platform measurementsClinical Biomechanics, 1992