Jessica DeBerardinis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jessica DeBerardinis has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Janet S. Dufek
Department of Kinesiology and Nutrition Sciences, University of Nevada Las Vegas, Las Vegas, NV 89154, USA
3 shared publications - Mohamed B. Trabia
Department of Mechanical Engineering, Howard R. Hughes College of Engineering, University of Nevada, Las Vegas, NV 89154, USA
3 shared publications - Daniel E. Lidstone
School of Behavioral Sciences and Education, Penn State Harrisburg Middletown Pennsylvania USA
2 shared publications Janet S Dufek
Department of Kinesiology and Nutrition Sciences, University of Nevada Las Vegas, Las Vegas, USA
2 shared publicationsJanet S. Dufek
Department of Kinesiology and Nutrition Sciences, University of Nevada Las Vegas, Las Vegas, NV
2 shared publicationsMohamed B Trabia
Department of Mechanical Engineering, University of Nevada Las Vegas, Las Vegas, USA
2 shared publications
Latest Publications
- Open Access
Use of Pressure-Measuring Insoles to Characterize Gait Parameters in Simulated Reduced-Gravity Conditions
Prior researchers have observed the effect of simulated reduced-gravity exercise. However, the extent to which lower-body positive-pressure treadmill (LBPPT) walking alters kinematic gait characteristics is not well understood. The purpose of the study was to investigate the effect of LBPPT walking on selected gait parameters in simulated reduced-gravity conditions. Twenty-nine college-aged volunteers participated in this cross-sectional study. Participants wore pressure-measuring insoles (Medilogic GmBH, Schönefeld, Germany) and completed three 3.5-min walking trials on the LBPPT (AlterG, Inc., Fremont, CA, USA) at 100% (normal gravity) as well as reduced-gravity conditions of 40% and 20% body weight (BW). The resulting insole data were analyzed to calculate center of pressure (COP) variables: COP path length and width and stance time. The results showed that 100% BW condition was significantly different from both the 40% and 20% BW conditions, p < 0.05. There were no significant differences observed between the 40% and 20% BW conditions for COP path length and width. Conversely, stance time significantly differed between the 40% and 20% BW conditions. The findings of this study may prove beneficial for clinicians as they develop rehabilitation strategies to effectively unload the individual’s body weight to perform safe exercises.
Open AccessUse of Pressure-Measuring Insoles to Characterize Gait Parameters in Simulated Reduced-Gravity Conditions
Prior researchers have observed the effect of simulated reduced-gravity exercise. However, the extent to which lower-body positive-pressure treadmill (LBPPT) walking alters kinematic gait characteristics is not well understood. The purpose of the study was to investigate the effect of LBPPT walking on selected gait parameters in simulated reduced-gravity conditions. Twenty-nine college-aged volunteers participated in this cross-sectional study. Participants wore pressure-measuring insoles (Medilogic GmBH, Schönefeld, Germany) and completed three 3.5-min walking trials on the LBPPT (AlterG, Inc., Fremont, CA, USA) at 100% (normal gravity) as well as reduced-gravity conditions of 40% and 20% body weight (BW). The resulting insole data were analyzed to calculate center of pressure (COP) variables: COP path length and width and stance time. The results showed that 100% BW condition was significantly different from both the 40% and 20% BW conditions, p < 0.05. There were no significant differences observed between the 40% and 20% BW conditions for COP path length and width. Conversely, stance time significantly differed between the 40% and 20% BW conditions. The findings of this study may prove beneficial for clinicians as they develop rehabilitation strategies to effectively unload the individual’s body weight to perform safe exercises.
- 8 October 2020
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 143 (1)
Enhancing the Accuracy of Vertical Ground Reaction Force Measurement During Walking Using Pressure-Measuring Insoles
Pressure-measuring insoles can be an attractive tool for measuring ground reaction force (GRF) since they are portable and can record multiple consecutive steps. Several researchers have, however, observed that these insoles are less accurate than instrumented force platforms. To address this issue, the authors identified transfer functions that best described each insole size to enhance the measurements of the vertical component of GRF during walking. GRF data were collected from 29 participants (6/23 male/female, 24.3 ± 6.7 yrs, 70.4 ± 23.9 kg, 1.66 ± 0.11 m) using Medilogic® pressure-measuring insoles and Kistler® force platforms for three walking trials. Participants provided the institutionally approved written consent (IRB #724468). The data from both instruments were preprocessed. A subset of the data was used to train the system identification toolbox (matlab) to identify the coefficients of several candidate transfer functions for each insole size. The resulting transfer functions were compared using all available data for each insole to assess which one modified the insole data to be closer to that of the force platform. All tested transfer functions moved the vertical component of GRF closer to the corresponding force platform data. Each insole size had a specific transfer model that that yielded the best results. Using system identification techniques produced transfer functions that, when using insole data of the vertical component of GRF as input, produced output that is comparable to the corresponding measurement using an instrumented force platform.
- 8 October 2020
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 143 (1)
Enhancing the Accuracy of Vertical Ground Reaction Force Measurement During Walking Using Pressure-Measuring Insoles
Pressure-measuring insoles can be an attractive tool for measuring ground reaction force (GRF) since they are portable and can record multiple consecutive steps. Several researchers have, however, observed that these insoles are less accurate than instrumented force platforms. To address this issue, the authors identified transfer functions that best described each insole size to enhance the measurements of the vertical component of GRF during walking. GRF data were collected from 29 participants (6/23 male/female, 24.3 ± 6.7 yrs, 70.4 ± 23.9 kg, 1.66 ± 0.11 m) using Medilogic® pressure-measuring insoles and Kistler® force platforms for three walking trials. Participants provided the institutionally approved written consent (IRB #724468). The data from both instruments were preprocessed. A subset of the data was used to train the system identification toolbox (matlab) to identify the coefficients of several candidate transfer functions for each insole size. The resulting transfer functions were compared using all available data for each insole to assess which one modified the insole data to be closer to that of the force platform. All tested transfer functions moved the vertical component of GRF closer to the corresponding force platform data. Each insole size had a specific transfer model that that yielded the best results. Using system identification techniques produced transfer functions that, when using insole data of the vertical component of GRF as input, produced output that is comparable to the corresponding measurement using an instrumented force platform.
- Open Access
- 1 January 2020
- Published by SAGE Publications in Journal of Rehabilitation and Assistive Technologies Engineering
- Vol. 7
A comparison of two techniques for center of pressure measurements
Introduction: Force platforms and pressure-measuring insoles are the most common tools used for measuring center of pressure. Earlier studies to assess these instruments suffered from limited sample sizes or an inadequate range of participant foot sizes. The purpose of this study was to propose new methods to extract and calculate comparably accurate center of pressure for the Kistler® force platform and Medilogic® insoles. Methods: Center of pressure data were collected from 65 participants wearing pressure-measuring insoles (six different sizes). Participants walked over consecutive force platforms for three trials while wearing pressure-measuring insoles within socks. Onset force thresholds and center of pressure segment length thresholds were used to determine accurate center of pressure path length and width. A single step for each foot and trial was extracted from both instruments. Results: A strong correlation was observed between instruments in center of pressure length (4.12 ± 6.72% difference, r = 0.74). Center of pressure width varied and was weakly correlated (–7.04 ± 4.48% difference, r = 0.11). Conclusions: The results indicate that both instruments can measure center of pressure path length consistently and with comparable accuracy (differences < 10%). There were differences between instruments in measuring center of pressure path width, which were attributed to the limited number of sensors across the width of the insoles.
- 1 January 2020
- Published by SAGE Publications in Journal of Rehabilitation and Assistive Technologies Engineering
- Vol. 7
Open AccessA comparison of two techniques for center of pressure measurements
Introduction: Force platforms and pressure-measuring insoles are the most common tools used for measuring center of pressure. Earlier studies to assess these instruments suffered from limited sample sizes or an inadequate range of participant foot sizes. The purpose of this study was to propose new methods to extract and calculate comparably accurate center of pressure for the Kistler® force platform and Medilogic® insoles. Methods: Center of pressure data were collected from 65 participants wearing pressure-measuring insoles (six different sizes). Participants walked over consecutive force platforms for three trials while wearing pressure-measuring insoles within socks. Onset force thresholds and center of pressure segment length thresholds were used to determine accurate center of pressure path length and width. A single step for each foot and trial was extracted from both instruments. Results: A strong correlation was observed between instruments in center of pressure length (4.12 ± 6.72% difference, r = 0.74). Center of pressure width varied and was weakly correlated (–7.04 ± 4.48% difference, r = 0.11). Conclusions: The results indicate that both instruments can measure center of pressure path length consistently and with comparable accuracy (differences < 10%). There were differences between instruments in measuring center of pressure path width, which were attributed to the limited number of sensors across the width of the insoles.
- Open Access
- 1 November 2019
- Published by MDPI AG in Journal of the American Podiatric Medical Association
- Vol. 109 (6) , 416-425
Concurrent Validity of an Automated Footprint Detection Algorithm to Measure Plantar Contact Area During Walking
Background: Monitoring footprints during walking can lead to better identification of foot structure and abnormalities. Current techniques for footprint measurements are either static or dynamic, with low resolution. This work presents an approach to monitor the plantar contact area when walking using high-speed videography. Methods: Footprint images were collected by asking the participants to walk across a custom-built acrylic walkway with a high-resolution digital camera placed directly underneath the walkway. This study proposes an automated footprint identification algorithm (Automatic Identification Algorithm) to measure the footprint throughout the stance phase of walking. This algorithm used coloration of the plantar tissue that was in contact with the acrylic walkway to distinguish the plantar contact area from other regions of the foot that were not in contact. Results: The intraclass correlation coefficient (ICC) demonstrated strong agreement between the proposed automated approach and the gold standard manual method (ICC = 0.939). Strong agreement between the two methods also was found for each phase of stance (ICC > 0.78). Conclusions: The proposed automated footprint detection technique identified the plantar contact area during walking with strong agreement with a manual gold standard method. This is the first study to demonstrate the concurrent validity of an automated identification algorithm to measure the plantar contact area during walking.
- 1 November 2019
- Published by MDPI AG in Journal of the American Podiatric Medical Association
- Vol. 109 (6) , 416-425
Open AccessConcurrent Validity of an Automated Footprint Detection Algorithm to Measure Plantar Contact Area During Walking
Background: Monitoring footprints during walking can lead to better identification of foot structure and abnormalities. Current techniques for footprint measurements are either static or dynamic, with low resolution. This work presents an approach to monitor the plantar contact area when walking using high-speed videography. Methods: Footprint images were collected by asking the participants to walk across a custom-built acrylic walkway with a high-resolution digital camera placed directly underneath the walkway. This study proposes an automated footprint identification algorithm (Automatic Identification Algorithm) to measure the footprint throughout the stance phase of walking. This algorithm used coloration of the plantar tissue that was in contact with the acrylic walkway to distinguish the plantar contact area from other regions of the foot that were not in contact. Results: The intraclass correlation coefficient (ICC) demonstrated strong agreement between the proposed automated approach and the gold standard manual method (ICC = 0.939). Strong agreement between the two methods also was found for each phase of stance (ICC > 0.78). Conclusions: The proposed automated footprint detection technique identified the plantar contact area during walking with strong agreement with a manual gold standard method. This is the first study to demonstrate the concurrent validity of an automated identification algorithm to measure the plantar contact area during walking.
- 30 May 2019
- Published by Elsevier in Journal of Biomechanics
- Vol. 92, 137-145
A viscoelastic ellipsoidal model of the mechanics of plantar tissues
- 30 May 2019
- Published by Elsevier in Journal of Biomechanics
- Vol. 92, 137-145
A viscoelastic ellipsoidal model of the mechanics of plantar tissues
- Open Access
- 12 January 2018
- Published by SAGE Publications in Journal of Rehabilitation and Assistive Technologies Engineering
- Vol. 5
Assessing the validity of pressure-measuring insoles in quantifying gait variables
Introduction: Pressure-measuring insoles can provide a portable alternative to existing gait analysis tools. However, there is disagreement among researchers on their accuracy and the appropriate calibration methods. The purposes of this study were to (1) determine the validity of pressure-measuring insoles for calculating stance time and support-phase impulse during walking using two calibration procedures, and (2) examine the effect of insole size on the results. Methods: Data were collected from 39 participants (23.5 ± 3.24 yrs, 66.7 ± 17.5 kg, 1.64 ± 0.09 m), each wearing appropriately sized insoles as they walked over two consecutive force platforms. Two calibration methods were evaluated: (1) manufacturer’s recommendation, and (2) a participant weight-based approach. Qualitative and quantitative evaluations were conducted. Results: The results indicated that the insoles measured longer stance times than the force platform (differences are less than 10%). Both calibration methods resulted in inaccurate impulse values (differences are 30 and 50% for the two calibration methods, respectively). The results showed that when using the first calibration method, impulse values depended on insole size. The second calibration consistently underestimated the impulse. Conclusions: It was concluded that while the insoles provide acceptable qualitative representation of the gait, the two studied calibration methods may lead to a misleading quantitative assessment.
- 12 January 2018
- Published by SAGE Publications in Journal of Rehabilitation and Assistive Technologies Engineering
- Vol. 5
Open AccessAssessing the validity of pressure-measuring insoles in quantifying gait variables
Introduction: Pressure-measuring insoles can provide a portable alternative to existing gait analysis tools. However, there is disagreement among researchers on their accuracy and the appropriate calibration methods. The purposes of this study were to (1) determine the validity of pressure-measuring insoles for calculating stance time and support-phase impulse during walking using two calibration procedures, and (2) examine the effect of insole size on the results. Methods: Data were collected from 39 participants (23.5 ± 3.24 yrs, 66.7 ± 17.5 kg, 1.64 ± 0.09 m), each wearing appropriately sized insoles as they walked over two consecutive force platforms. Two calibration methods were evaluated: (1) manufacturer’s recommendation, and (2) a participant weight-based approach. Qualitative and quantitative evaluations were conducted. Results: The results indicated that the insoles measured longer stance times than the force platform (differences are less than 10%). Both calibration methods resulted in inaccurate impulse values (differences are 30 and 50% for the two calibration methods, respectively). The results showed that when using the first calibration method, impulse values depended on insole size. The second calibration consistently underestimated the impulse. Conclusions: It was concluded that while the insoles provide acceptable qualitative representation of the gait, the two studied calibration methods may lead to a misleading quantitative assessment.