Torsional Behavior of Circular Concrete-Filled FRP Tubes
- 1 June 2021
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 25 (3) , 04021013
Abstract
Concrete-filled fiber-reinforced polymer (FRP) tubes (CFFTs) have been studied extensively under almost all loading conditions, except torsion. In this pioneering study, six 168-mm-diameter samples were tested in pure torsion, consisting of two hollow glass-FRP tubes and four CFFTs. Two tubes with distinctly different laminate structures were tested and compared, namely, near-cross-ply and angle-ply tubes. A specially designed Z-shape setup with unique features intended to avoid second-order effects and facilitate gripping of the circular section was developed and used to apply pure torsion. The results showed that the postcracking response was heavily dependent on the FRP tube laminate structure. The tube confined the concrete core diagonal struts, as evident by a state of combined stresses in the tube, which ultimately fractured. The concrete core prevented buckling of the tubes and resulted in a 250% increase in ultimate torques over the hollow tubes. It also increased twist angles by 14% and 45% for CFFTs with near-cross-ply and angle-ply tubes, respectively. The angle-ply CFFT achieved a 118% increase in ultimate torque but was 48% lower in ultimate twist, compared to the near-cross-ply CFFT, with the latter showing a significant nonlinear response. A simplified analytical model based on the superposition of the truss action and membrane shear action of the tube was developed and verified. It was then used in a parametric study to examine the effect of the laminate structure and tube thickness on torsional strength, ranging from the lower bound based on the [0°/90°]s cross-ply tube to the upper bound based on the [±45°]s angle-ply tube.Keywords
This publication has 22 references indexed in Scilit:
- Experimental study on seismic behavior of concrete filled steel tube columns under pure torsion and compression–torsion cyclic loadJournal of Constructional Steel Research, 2012
- Torsional Behavior of Concrete-Filled Circular Steel Tube ColumnsJournal of Structural Engineering, 2009
- Use of Torsion Tubes to Measure In-Plane Shear Properties of Filament-Wound Composites2008
- Experimental investigation of thin-walled centrifugal concrete-filled steel tubes under torsionThin-Walled Structures, 2008
- Torsional strengthening of rectangular and flanged beams using carbon fibre-reinforced-polymers – Experimental studyConstruction and Building Materials, 2008
- Performance of concrete-filled thin-walled steel tubes under pure torsionThin-Walled Structures, 2007
- Behavior of Concrete Columns Confined by Fiber CompositesJournal of Structural Engineering, 1997
- Predicting the mechanical behaviour of Kevlar/epoxy and carbon/epoxy filament-wound tubesComposites, 1992
- Carbon and aramid reinforced plastics in the manufacture of automotive propeller shafts Part 2Materials & Design (1980-2015), 1983
- Instability of orthotropic cylindrical shells under combined torsionand hydrostatic pressure.AIAA Journal, 1967