JOJames St. Onge

James St. Onge

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Research Subjects


James St. Onge has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Concrete-Filled FRP Tubes under Combined Torsion and Bending

    by James St. Onge, Amir Fam

    The combined torsion and bending response of concrete-filled fiber-reinforced polymer (FRP) tubes (CFFTs) was investigated in this study. The CFFT samples were produced from the same 166-mm-diameter nearly cross-ply filament wound glass-FRP (GFRP) tubes with a 30 MPa concrete infill. The samples were tested at torque-to-bending moment ratios (T/M) of 2, 1, and 0.67, as well as under pure bending and pure torsion, to cover a wide range of loading cases. The study showed that ultimate torque and bending moment were minimally affected when combined with normalized bending moments (Mu/Muo) and normalized torques (Tu/Tuo) ≤ 0.5, respectively. A circular normalized ultimate strength interaction could reasonably predict the trend of the experimental data. The postcracking torsional stiffness was not greatly affected by flexure; however, late-stage stiffness was improved at T/M = 2, while it was reduced at T/M = 0.67. The flexural stiffness remained largely unchanged with T/M. Reducing T/M from 2 to 0.67 reduced the twist capacity from 52% to 27% of that at pure torsion but increased the deflection from 41% to 75% of that at pure flexure. Reducing T/M from pure torsion reduces the hoop and shear strains and produces a longitudinal strain gradient over the section height. The strain gradient limits the formation of diagonal cracks in the flexural compression region, reduces the number of cracks, and produces a crack angle variation through the section depth. Failure initiates from rupture of the FRP tube under a complex state of in-plane normal and shear stresses at the flexural tension side of the tube, followed by failure of the concrete core, which experiences partial confinement.


  • Torsional Behavior of Circular Concrete-Filled FRP Tubes

    by James St. Onge, Amir Fam

    Concrete-filled fiber-reinforced polymer (FRP) tubes (CFFTs) have been studied extensively under almost all loading conditions, except torsion. In this pioneering study, six 168-mm-diameter samples were tested in pure torsion, consisting of two hollow glass-FRP tubes and four CFFTs. Two tubes with distinctly different laminate structures were tested and compared, namely, near-cross-ply and angle-ply tubes. A specially designed Z-shape setup with unique features intended to avoid second-order effects and facilitate gripping of the circular section was developed and used to apply pure torsion. The results showed that the postcracking response was heavily dependent on the FRP tube laminate structure. The tube confined the concrete core diagonal struts, as evident by a state of combined stresses in the tube, which ultimately fractured. The concrete core prevented buckling of the tubes and resulted in a 250% increase in ultimate torques over the hollow tubes. It also increased twist angles by 14% and 45% for CFFTs with near-cross-ply and angle-ply tubes, respectively. The angle-ply CFFT achieved a 118% increase in ultimate torque but was 48% lower in ultimate twist, compared to the near-cross-ply CFFT, with the latter showing a significant nonlinear response. A simplified analytical model based on the superposition of the truss action and membrane shear action of the tube was developed and verified. It was then used in a parametric study to examine the effect of the laminate structure and tube thickness on torsional strength, ranging from the lower bound based on the [0°/90°]s cross-ply tube to the upper bound based on the [±45°]s angle-ply tube.


  • Damage Threshold of Near-Cross-Ply Tubes Used in Concrete-Filled FRP Tubes Loaded in Flexure

    by Chenxi Lu, James St. Onge, Amir Fam

    Concrete-filled fiber-reinforced polymer (FRP) tubes (CFFTs) have been studied extensively, but a lingering question remains regarding the vulnerability of the exposed tube to accidental damage or vandalism. In this paper, the effect of damage induced in the tubes on the flexural strength of CFFTs is studied. A total of 18 specimens with tubes having nearly orthogonal fiber arrangements were tested in four-point bending, including one undamaged control specimen to establish its full nominal strength (Mno ). A total of 11 specimens with artificially induced damage in the form of through-thickness cuts on the tension side, and six with cuts on the compression side at midspan were also tested. Longitudinal, circumferential, and square cuts were introduced. Cut length and proximity to neutral axis were varied. It is shown that the most critical cut is the circumferential one on extreme tension. A sharp decline occurred initially in the nominal residual strength ratio (Mn/Mno ), from 1.0 to 0.55 at a cut length-to-perimeter ratio of 0.02πD , followed by a much less steep trend up to Mn/Mno of 0.25 at a 0.2πD cut. As the location of a 0.03πD circumferential cut shifted from extreme tension to an 80° from the bottom, Mn/Mno increased from 0.52 to 1.0. A longitudinal cut of 0.1πD on the tension side resulted in Mn/Mno of 0.69 as opposed to 0.38 for the circumferential cut. Compression side longitudinal and circumferential cuts were less critical with Mn/Mno of 0.8 to 0.9. For practical design, a case study based on ultimate static strength showed that the CFFT can tolerate a circumferential tension cut of up to 0.29πD before it has to be taken out of service.