Reverse trajectory analysis of the hydrogen negative ion beam in a prototype accelerator for ITER
Open Access
- 1 April 2022
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2244 (1) , 012061
Abstract
Reverse calculation of negative ion trajectory based on the measured beam emittance has been performed for the first time in multi-stage accelerator in order to reconstruct negative ion profile near meniscus, which has been a long-term issue for negative ion sources. According to reverse calculation, negative ions are mainly extracted from the periphery of extraction area, and the particles extracted from the aperture edge is lost on acceleration grids. By taking into account the lost component with reconstructed negative ion profile, the negative ion trajectory became consistent with observed beam traces on the acceleration grids. This result can be applied directly to the design of ITER accelerator as well as the other Cs-seeded negative ion sources.Keywords
This publication has 6 references indexed in Scilit:
- Development of long-pulse high-power-density negative ion beams with a multi-aperture multi-grid acceleratorFusion Engineering and Design, 2017
- Overview of the design of the ITER heating neutral beam injectorsNew Journal of Physics, 2017
- PIC modeling of negative ion sources for fusionNew Journal of Physics, 2017
- Detailed design optimization of the MITICA negative ion accelerator in view of the ITER NBINuclear Fusion, 2015
- Measurement of heat load density profile on acceleration grid in MeV-class negative ion acceleratorReview of Scientific Instruments, 2015
- A model for negative ion extraction and comparison of negative ion optics calculations to experimental resultsReview of Scientific Instruments, 1991