Atsushi Kojima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Atsushi Kojima has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Hiroyuki Tobari
National Institutes for Quantum Science and Technology (QST), Naka, Ibaraki, Japan
4 shared publications - Mieko Kashiwagi
National Institutes for Quantum and Radiological Science and Technology (QST)
4 shared publications - Kazuhiro Watanabe
Theory Center, Jefferson Laboratory, Newport News, Virginia 23606, USA
3 shared publications - Hiroyuki Moriyama
Tokai University
2 shared publications - Junichi Hiratsuka
Fusion Energy Directorate, National Institutes for Quantum Science and Technology , Naka, Ibaraki 311-0193, Japan
2 shared publications - Masamichi Murayama
National Institutes for Quantum Science and Technology, 801-1 Mukoyama, Naka, Ibaraki 311-0193, Japan
2 shared publications
Latest Publications
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Lessons Learned From EF1 Electrical Short Incident During JT-60SA Integrated Commissioning Test
The superconducting tokamak fusion test device, JT-60SA, was constructed as the Satellite Tokamak project in the Broader Approach Program between Japan and EU. During the JT-60SA integrated commissioning tests of the Nb-Ti equilibrium magnetic field coil EF1 high voltage (∼5 kV) test, the EF1 power supply current surged suddenly and was stopped by the overcurrent interlock of the power supply. At the same time, the vacuum in the cryostat deteriorated, and the pressure in the magnet cooling loops increased. After the system warmed up, visual inspection revealed that discharges occurred between ground and both positive and negative terminal joints of EF1. Several holes, melted by the electrical short and identified as the source of the helium leak into the cryostat, were found in the cylindrical metal part of the joint. The data recorded at the time of the event were analyzed with a conclusion that the discharge first occurred between the positive terminal joint and its support bracket at ground potential and immediately afterward between the neighboring negative terminal joint and its support bracket. These two arcs created a short-circuited loop through which the coil discharged for about 1.4 s. The energy during the short circuit is estimated to be about 60 kJ.
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Lessons Learned From EF1 Electrical Short Incident During JT-60SA Integrated Commissioning Test
The superconducting tokamak fusion test device, JT-60SA, was constructed as the Satellite Tokamak project in the Broader Approach Program between Japan and EU. During the JT-60SA integrated commissioning tests of the Nb-Ti equilibrium magnetic field coil EF1 high voltage (∼5 kV) test, the EF1 power supply current surged suddenly and was stopped by the overcurrent interlock of the power supply. At the same time, the vacuum in the cryostat deteriorated, and the pressure in the magnet cooling loops increased. After the system warmed up, visual inspection revealed that discharges occurred between ground and both positive and negative terminal joints of EF1. Several holes, melted by the electrical short and identified as the source of the helium leak into the cryostat, were found in the cylindrical metal part of the joint. The data recorded at the time of the event were analyzed with a conclusion that the discharge first occurred between the positive terminal joint and its support bracket at ground potential and immediately afterward between the neighboring negative terminal joint and its support bracket. These two arcs created a short-circuited loop through which the coil discharged for about 1.4 s. The energy during the short circuit is estimated to be about 60 kJ.
- Open Access
- 1 April 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2244 (1) , 012061
Reverse trajectory analysis of the hydrogen negative ion beam in a prototype accelerator for ITER
Reverse calculation of negative ion trajectory based on the measured beam emittance has been performed for the first time in multi-stage accelerator in order to reconstruct negative ion profile near meniscus, which has been a long-term issue for negative ion sources. According to reverse calculation, negative ions are mainly extracted from the periphery of extraction area, and the particles extracted from the aperture edge is lost on acceleration grids. By taking into account the lost component with reconstructed negative ion profile, the negative ion trajectory became consistent with observed beam traces on the acceleration grids. This result can be applied directly to the design of ITER accelerator as well as the other Cs-seeded negative ion sources.
- 1 April 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2244 (1) , 012061
Open AccessReverse trajectory analysis of the hydrogen negative ion beam in a prototype accelerator for ITER
Reverse calculation of negative ion trajectory based on the measured beam emittance has been performed for the first time in multi-stage accelerator in order to reconstruct negative ion profile near meniscus, which has been a long-term issue for negative ion sources. According to reverse calculation, negative ions are mainly extracted from the periphery of extraction area, and the particles extracted from the aperture edge is lost on acceleration grids. By taking into account the lost component with reconstructed negative ion profile, the negative ion trajectory became consistent with observed beam traces on the acceleration grids. This result can be applied directly to the design of ITER accelerator as well as the other Cs-seeded negative ion sources.
- 27 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 57, 420-425
Vacuum Insulation in Negative Ion Accelerator with Long Gap and Large Surface for Fusion Application
A scaling technique has been developed in order to predict the voltage holding capability of the world-largest electrostatic accelerator for fusion application having a long gap vacuum insulation around 1 m with large surface area of more than 6 m 2 . One of critical issues for design of such large-size accelerator is the development of the prediction model based on the experimental results. For this purpose, the 1/5 scale mockup has been developed, which is composed of the 5-stage accelerator with the high voltage bushing in the vacuum vessel. Direct comparison of the sustainable voltages in the 1/5 scale and full-scale high voltage busing only shows that a voltage scaling in 1/5 scale size is 55%. It was found that the voltage scaling is consistent with the prediction based on the empirical scaling according to the surface area and gap length. As a result, the voltage holding capability of the 1/5 scale mockup is 400 kV in the experiment, which indicates an estimation of 720 kV in full-scale with a real configuration. This is the first experiment-based prediction of the voltage holding capability for the largest accelerator for ITER. The improvement of the voltage holding capability has been already planned by using multi-layer electrostatic shields. In such experiment, the developed scaling technique is useful to predict the voltage holding capability for large vacuum components which can not be easily tested.
- 27 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 57, 420-425
Vacuum Insulation in Negative Ion Accelerator with Long Gap and Large Surface for Fusion Application
A scaling technique has been developed in order to predict the voltage holding capability of the world-largest electrostatic accelerator for fusion application having a long gap vacuum insulation around 1 m with large surface area of more than 6 m 2 . One of critical issues for design of such large-size accelerator is the development of the prediction model based on the experimental results. For this purpose, the 1/5 scale mockup has been developed, which is composed of the 5-stage accelerator with the high voltage bushing in the vacuum vessel. Direct comparison of the sustainable voltages in the 1/5 scale and full-scale high voltage busing only shows that a voltage scaling in 1/5 scale size is 55%. It was found that the voltage scaling is consistent with the prediction based on the empirical scaling according to the surface area and gap length. As a result, the voltage holding capability of the 1/5 scale mockup is 400 kV in the experiment, which indicates an estimation of 720 kV in full-scale with a real configuration. This is the first experiment-based prediction of the voltage holding capability for the largest accelerator for ITER. The improvement of the voltage holding capability has been already planned by using multi-layer electrostatic shields. In such experiment, the developed scaling technique is useful to predict the voltage holding capability for large vacuum components which can not be easily tested.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 721-730
HV Holding in Vacuum, a Key Issue for the ITER Neutral Beam Injector
This overview summarizes the R&D activities aimed to secure for the ITER Neutral Beam Injectors a stable voltage holding, one of the most challenging issue for the NBI systems operation. The huge size of the accelerator and the highest voltage (1 MV) ever used in such systems make prominent some aspects that are, in other application, almost not influent or well under control, like the Area Effect, Total Voltage Effect, the highly complex electrostatic configuration and, last but not least, the cleaning degree of the electrodes surfaces. A clear explanation of the mechanism leading to the voltage breakdown in these conditions is far from being well established. But in the last years a great effort have been deployed by the NBI community to reliably achieve 1 MV voltage holding that is required for the NB injectors for ITER. Theoretical models and new tools have been derived to explain the mechanism of voltage conditioning and for the design of the complex electrodes geometries, that supersede the simple electric field optimization. The 1 MV across a single gap has not yet been achieved but, on the basis of the results so far obtained, it is now considered to be achievable.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 721-730
HV Holding in Vacuum, a Key Issue for the ITER Neutral Beam Injector
This overview summarizes the R&D activities aimed to secure for the ITER Neutral Beam Injectors a stable voltage holding, one of the most challenging issue for the NBI systems operation. The huge size of the accelerator and the highest voltage (1 MV) ever used in such systems make prominent some aspects that are, in other application, almost not influent or well under control, like the Area Effect, Total Voltage Effect, the highly complex electrostatic configuration and, last but not least, the cleaning degree of the electrodes surfaces. A clear explanation of the mechanism leading to the voltage breakdown in these conditions is far from being well established. But in the last years a great effort have been deployed by the NBI community to reliably achieve 1 MV voltage holding that is required for the NB injectors for ITER. Theoretical models and new tools have been derived to explain the mechanism of voltage conditioning and for the design of the complex electrodes geometries, that supersede the simple electric field optimization. The 1 MV across a single gap has not yet been achieved but, on the basis of the results so far obtained, it is now considered to be achievable.
- 26 November 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (2) , 02B312
100 s extraction of negative ion beams by using actively temperature-controlled plasma grid
Long pulse beam extraction with a current density of 120 A/m2 for 100 s has been achieved with a newly developed plasma grid (PG) for the JT-60SA negative ion source which is designed to produce high power and long pulse beams with a negative ion current of 130 A/m2 (22 A) and a pulse length of 100 s. The PG temperature is regulated by fluorinated fluids in order to keep the high PG temperature for the cesium-seeded negative ion production. The time constant for temperature controllability of the PG was measured to be below 10 s, which was mainly determined by the heat transfer coefficient of the fluorinated fluid. The measured decay time of the negative ion current extracted from the actively temperature-controlled PG was 430 s which was sufficient for the JT-60SA requirement, and much longer than that by inertial-cooling PG of 60 s. Obtained results of the long pulse capability are utilized to design the full size PG for the JT-60SA negative ion source.
- 26 November 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (2) , 02B312
100 s extraction of negative ion beams by using actively temperature-controlled plasma grid
Long pulse beam extraction with a current density of 120 A/m2 for 100 s has been achieved with a newly developed plasma grid (PG) for the JT-60SA negative ion source which is designed to produce high power and long pulse beams with a negative ion current of 130 A/m2 (22 A) and a pulse length of 100 s. The PG temperature is regulated by fluorinated fluids in order to keep the high PG temperature for the cesium-seeded negative ion production. The time constant for temperature controllability of the PG was measured to be below 10 s, which was mainly determined by the heat transfer coefficient of the fluorinated fluid. The measured decay time of the negative ion current extracted from the actively temperature-controlled PG was 430 s which was sufficient for the JT-60SA requirement, and much longer than that by inertial-cooling PG of 60 s. Obtained results of the long pulse capability are utilized to design the full size PG for the JT-60SA negative ion source.
- Open Access
- 1 January 2011
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Dynamics & Design Conference
- Vol. 2011, _728-1_
728 Vibroacoustic coupling phenomenon between an excited plate and internal sound fields of connected cylindrical structure
- 1 January 2011
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Dynamics & Design Conference
- Vol. 2011, _728-1_
Open Access728 Vibroacoustic coupling phenomenon between an excited plate and internal sound fields of connected cylindrical structure
- Open Access
- 1 January 2010
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Dynamics & Design Conference
- Vol. 2010, _754-1_
754 Acoustic Characteristics of Internal Sound Field in Cylindrical Structure with Both Excited End Plates
Vibroacoustic coupling phenomena occur in a variety of different situations and are generally studied with the goal of controlling noise. We consider a cylindrical structure with thin plates at both ends and investigate the coupling between the plate vibrations and the internal sound field when external periodic forces are applied to respective end plates. In comparison between characteristics of the both systems, it is clarified that vibroacoustic coupling is effective in increasing acoustic energy and the phase difference depends greatly on the acoustic mode, which contributes the formation of the sound field.
- 1 January 2010
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Dynamics & Design Conference
- Vol. 2010, _754-1_
Open Access754 Acoustic Characteristics of Internal Sound Field in Cylindrical Structure with Both Excited End Plates
Vibroacoustic coupling phenomena occur in a variety of different situations and are generally studied with the goal of controlling noise. We consider a cylindrical structure with thin plates at both ends and investigate the coupling between the plate vibrations and the internal sound field when external periodic forces are applied to respective end plates. In comparison between characteristics of the both systems, it is clarified that vibroacoustic coupling is effective in increasing acoustic energy and the phase difference depends greatly on the acoustic mode, which contributes the formation of the sound field.