Performance of closed-loop resuscitation in a pig model of haemorrhagic shock with fluid alone or in combination with norepinephrine, a pilot study
- 12 June 2020
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 35 (4) , 835-847
Abstract
We evaluated the performance of a new device to control the administration of fluid alone or co-administration of fluid and norepinephrine in a pig model of haemorrhagic shock in two sets of experiments. In the first one, resuscitation was guided using continuous arterial pressure measurements (three groups: resuscitation with fluid by a physician, CL resuscitation with fluid, and CL resuscitation with fluid and norepinephrine). In the second one, resuscitation was guided using discontinuous arterial pressure measurements (three groups: CL resuscitation with fluid alone, CL resuscitation with fluid and moderate dose norepinephrine, and CL resuscitation with fluid and a high dose of norepinephrine). Pigs were resuscitated for 1 h. In the first set of experiments, proportion of time spent in the target area of 78–88 mmHg of systolic arterial pressure was not statistically different between the three groups: manual, 71.2% (39.1–80.1); CL with fluid, 87.8% (68.3–97.4); and CL with fluid and norepinephrine, 78.1% (59.2–83.6), p = 0.151. In the second set of experiments, performance of CL resuscitation with fluid or with combination of fluid and high or moderate dose of norepinephrine was not significantly different (p = 0.543 for time in target). Pigs resuscitated with norepinephrine required less fluid and had less haemodilution than pigs resuscitated with fluid alone. Performance of CL resuscitation using continuous arterial pressure measurement was not significantly different than optimised manual treatment by a dedicated physician. Performance of CL resuscitation was reduced with discontinuous arterial pressure measurements in comparison with continuous arterial pressure measurements.Keywords
Funding Information
- Mission Innovation Participative
- BIOMEDEF
This publication has 25 references indexed in Scilit:
- The European guideline on management of major bleeding and coagulopathy following trauma: fourth editionCritical Care, 2016
- Assessment of an updated double‐vasopressor automated system using Nexfin ™ for the maintenance of haemodynamic stability to improve peri‐operative outcome during spinal anaesthesia for caesarean sectionAnaesthesia, 2015
- Closed-Loop Fluid Administration Compared to Anesthesiologist Management for Hemodynamic Optimization and Resuscitation During SurgeryAnesthesia & Analgesia, 2013
- Computerized decision support system improves fluid resuscitation following severe burns: An original study*Critical Care Medicine, 2011
- Closed-Loop Control of Fluid Therapy for Treatment of HypovolemiaJournal of Trauma: Injury, Infection & Critical Care, 2008
- Closed‐loop feedback computer‐controlled infusion of phenylephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: a preliminary descriptive study*Anaesthesia, 2007
- HYPERTONIC 15% SODIUM PYRUVATE OFFERS NO INITIAL RESUSCITATION ADVANTAGE COMPARED WITH 8% HYPERTONIC NACL IN SHEEP WITH MULTIPLE HEMORRHAGESShock, 2007
- Normotensive and hypotensive closed-loop resuscitation using 3.0% NaCl to treat multiple hemorrhages in sheep*Critical Care Medicine, 2006
- Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiographyBritish Journal of Anaesthesia, 2005
- Measuring the predictive performance of computer-controlled infusion pumpsJournal of Pharmacokinetics and Biopharmaceutics, 1992