Spatiotemporal Coherence to Quantify Sources of Image Degradation in Ultrasonic Imaging
- 30 March 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (4) , 1337-1352
Abstract
Thermal noise and acoustic clutter signals degrade ultrasonic image quality and contribute to unreliable clinical assessment. When both noise and clutter are prevalent, it is difficult to determine which one is a more significant contributor to image degradation because there is no way to separately measure their contributions in vivo . Efforts to improve image quality often rely on an understanding of the type of image degradation at play. To address this, we derived and validated a method to quantify the individual contributions of thermal noise and acoustic clutter to image degradation by leveraging spatial and temporal coherence characteristics. Using Field II simulations, we validated the assumptions of our method, explored strategies for robust implementation, and investigated its accuracy and dynamic range. We further proposed a novel robust approach for estimating spatial lag-one coherence. Using this robust approach, we determined that our method can estimate the signal-to-thermal noise ratio (SNR) and signal-to-clutter ratio (SCR) with high accuracy between SNR levels of −30 to 40 dB and SCR levels of −20 to 15 dB. We further explored imaging parameter requirements with our Field II simulations and determined that SNR and SCR can be estimated accurately with as few as two frames and sixteen channels. Finally, we demonstrate in vivo feasibility in brain imaging and liver imaging, showing that it is possible to overcome the constraints of in vivo motion using high-frame rate M-Mode imaging.Keywords
Funding Information
- National Science Foundation Graduate Research Fellowship Program (1937963)
- National Institute of Biomedical Imaging and Bioengineering under NIH (T32EB021937)
- National Institute of Biomedical Imaging and Bioengineering under NIH (R01EB020040)
- National Heart, Lung, and Blood Institute (R01HL156034)
- National Science Foundation CAREER Award (IIS-1750994)
This publication has 53 references indexed in Scilit:
- Inadequate Visualization and Reporting of Ventricular Function From Transthoracic Echocardiography After Cardiac SurgeryJournal of Cardiothoracic and Vascular Anesthesia, 2010
- Contrast enhanced ultrasound imagingJournal of Nuclear Cardiology, 2010
- The impact of maternal obesity on satisfactory detailed anatomic ultrasound image acquisitionThe Journal of Maternal-Fetal & Neonatal Medicine, 2009
- The impact of maternal obesity on midtrimester sonographic visualization of fetal cardiac and craniospinal structuresInternational Journal of Obesity, 2004
- Does advanced ultrasound equipment improve the adequacy of ultrasound visualization of fetal cardiac structures in the obese gravid woman?American Journal of Obstetrics and Gynecology, 2004
- The effect of abdominal wall morphology on ultrasonic pulse distortion. Part I. MeasurementsThe Journal of the Acoustical Society of America, 1998
- The effect of abdominal wall morphology on ultrasonic pulse distortion. Part II. SimulationsThe Journal of the Acoustical Society of America, 1998
- Transesophageal echocardiography predicts mortality in critically III patients with unexplained hypotensionJACC, 1995
- The van Cittert–Zernike theorem in pulse echo measurementsThe Journal of the Acoustical Society of America, 1991
- A model for the propagation and scattering of ultrasound in tissueThe Journal of the Acoustical Society of America, 1991