Dellen formation as a complication of subconjunctival silicone oil following microincision vitrectomy
Open Access
- 1 December 2017
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 11, 2215-2219
Abstract
Purpose: To study the subconjunctival silicone oil (SCSO) parameters associated with dellen formation following microincision vitrectomy (MIV). Patients and methods: This was a case–control study of 20 eyes with SCSO following MIV. Ten of them suffered postoperative dellen formation. Dellen occurrence, their sizes, number of loci, and distance between SCSO and the limbus were recorded. The outcome after silicone-oil removal was evaluated. Results: The SCSO was at 3.1±1.2 mm from the limbus. All cases with dellen had SCSO within 2 mm of the limbus (PP=0.414; sex, P=0.656; laterality, P=1; indication for pars plana vitrectomy, P=0.655; instrument gauge, P=0.211; circumference involved by SCSO, P=0.252). All the dellen healed after surgical evacuation of SCSO (PConclusion: Dellen can be associated with MIV secondary to SCSO near the limbus. Resolution with scarring occurred following SCSO evacuation. Therefore, SCSO should be evacuated as early as possible to avoid long-term peripheral corneal morbidity.Keywords
This publication has 18 references indexed in Scilit:
- Paecilomyces lilacinus-induced Scleritis Following Bleb-associated Endophthalmitis after Trabeculectomy.2015
- Faster recovery after 25-gauge microincision vitrectomy surgery than after 20-gauge vitrectomy in patients with proliferative diabetic retinopathyClinical Ophthalmology, 2012
- Transconjunctival sutureless 23-gauge vitrectomy for vitreoretinal diseases: Outcome of 30 consecutive casesMiddle East African Journal of Ophthalmology, 2008
- Retinal detachment surgery with silicone oil injection in transconjunctival sutureless 23-gauge vitrectomyArquivos Brasileiros de Oftalmologia, 2007
- Comparison of Visual Function After Epiretinal Membrane Removal by 20-Gauge and 25-Gauge VitrectomyAmerican Journal of Ophthalmology, 2006
- A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch and Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Subconjunctival silicone oil drainage through the Molteno implantKorean Journal of Ophthalmology, 1998
- Complications Associated with the Use of Silicone Oil in 150 Eyes after Retina-vitreous SurgeryOphthalmology, 1988
- Colchicine suppression of corneal healing after strabismus surgery.British Journal of Ophthalmology, 1977
- Corneal dellen in the limbal approach to rectus muscle surgery.British Journal of Ophthalmology, 1975